文献速递眼底病与葡萄膜炎

利用光学相干断层扫描识别中心性浆液性脉络膜视网膜病变渗漏点并评估生物标志物特征

IDENTIFICATION OF LEAKAGE SITES IN CENTRAL SEROUS CHORIORETINOPATHY USING OPTICAL COHERENCE TOMOGRAPHY AND THE ASSESSMENT OF THE CHARACTERISTICS OF THE BIOMARKERS.
PubMed 文献 · Retina · 2025-01-01

该回顾性病例对照研究分析2018年4月至2024年2月间119例(123眼)中心性浆液性脉络膜视网膜病变患者,比较局灶渗漏型(66眼)与弥漫渗漏型(57眼)的光学相干断层扫描表现,发现低反射透亮征仅见于局灶型渗漏点(40.9% vs 0.0%,P<0.001),提示其或可作为潜在治疗靶点。

要点

  • 低反射透亮征在局灶渗漏型中占40.9%,弥漫渗漏型中为0.0%(P<0.001)。
  • 视网膜色素上皮微撕裂在局灶型占34.8%,弥漫型占5.3%(P<0.001)。
  • 视网膜下高反射物质在局灶型占71.2%,弥漫型占19.3%(P<0.001)。

核心结论

  • 仅低反射透亮征专属于荧光素血管造影的局灶渗漏点,作者认为其或可作为中心性浆液性脉络膜视网膜病变的潜在治疗靶点。

研究设计与样本

  • 回顾性病例对照研究,纳入2018年4月至2024年2月间119例(123眼)中心性浆液性脉络膜视网膜病变患者,其中局灶渗漏型66眼、弥漫渗漏型57眼。

主要发现

  • 低反射透亮征见于局灶渗漏型27眼(40.9%),弥漫渗漏型0眼(0.0%),P<0.001。
  • 局灶渗漏型中低反射透亮征仅定位于渗漏点,浆液性视网膜脱离其他区域未见。
  • 视网膜色素上皮微撕裂在局灶渗漏型23眼(34.8%)、弥漫渗漏型5.3%,P<0.001。
  • 视网膜下高反射物质在局灶渗漏型47眼(71.2%)、弥漫渗漏型19.3%,P<0.001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To identify optical coherence tomography-based imaging biomarkers that can localize focal leakage points without fluorescein angiography in central serous chorioretinopathy (CSC). METHODS: This retrospective case-control study analyzed 119 consecutive patients (123 eyes) with CSC between April 2018 and February 2024, comprising 66 eyes with focal-leakage type and 57 eyes with diffuse-leakage type. We assessed leakage sites using optical coherence tomography, and the proportions of optical coherence tomography findings were compared between focal-leakage and diffuse-leakage types. RESULTS: Hyporeflective lucency signs were observed in 27 eyes (40.9%) with focal-type CSC, while no such signs were detected in diffuse-type CSC cases (0.0%; P < 0.001). In focal-type CSC, these signs were exclusively localized to leakage points, with no occurrence in other areas within serous retinal detachment. Microrips of retinal pigment epithelium and subretinal hyperreflective material were identified in 23 (34.8%) and 47 eyes (71.2%) with focal-type CSC, respectively, and also in eyes with diffuse-type CSC (5.3% and 19.3%, respectively; P < 0.001 for both comparisons). CONCLUSION: Only the hyporeflective lucency sign is present exclusively in focal leakage points of fluorescein angiography. Our findings suggested that the hyporeflective lucency sign may serve as a potential therapeutic target in CSC.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Funatsu R, Terasaki H, Mihara N, et al. IDENTIFICATION OF LEAKAGE SITES IN CENTRAL SEROUS CHORIORETINOPATHY USING OPTICAL COHERENCE TOMOGRAPHY AND THE ASSESSMENT OF THE CHARACTERISTICS OF THE BIOMARKERS. Retina. 2025. PMID: 39841922. doi:10.1097/IAE.0000000000004404

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。