文献速递眼底病与葡萄膜炎

使用IRIDEX激光系统行经巩膜睫状体平坦部脉络膜消融改善小型猪模型中端口给药植入物的手术植入

TRANSSCLERAL PARS PLANA CHOROID ABLATION USING THE IRIDEX LASER SYSTEM YIELDS IMPROVEMENTS FOR SURGICAL INSERTION OF THE PORT DELIVERY IMPLANT IN A MINIPIG MODEL.
PubMed 文献 · Retina · 2025-01-01

研究在17只雄性哥廷根小型猪中评估IRIDEX 810 nm红外二极管激光经巩膜睫状体平坦部消融辅助端口给药系统(PDS)植入的效果。最有效参数为连续波模式、1750 mW、1000 ms、16个光斑,总能量28 J,未观察到玻璃体积血及周围组织损伤。结论认为该激光应用可简化PDS植入手术。

要点

  • 最有效激光参数为连续波模式、1750 mW、1000 ms、16个光斑,总能量28 J。
  • 该参数下未观察到玻璃体积血,仅2个植入物出现轻微自限性巩膜出血。
  • 显微镜观察显示该激光设置下无组织损伤,微型CT与临床观察一致。

核心结论

  • 哥廷根小型猪模型显示IRIDEX激光经巩膜睫状体平坦部消融可简化端口给药系统植入手术。

研究设计与样本

  • 共17只雄性小型猪,第1部分9只非恢复性实验,第2部分8只术后观察8天,每只眼植入端口给药系统。

主要发现

  • 最有效激光参数为连续波模式、1750 mW、1000 ms、16个光斑(每扫8个重叠光斑,共两行),跨4 mm节段,位于角膜缘后方,总能量28 J。
  • 两个植入物出现轻微自限性巩膜出血,未观察到玻璃体积血。
  • 微型CT成像与临床眼科观察一致,显微镜观察显示该激光设置下无组织损伤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate an alternative surgical approach for Port Delivery System with ranibizumab implant and a novel application of Iridex laser system in Gottingen minipig model. METHODS: A total of 17 male minipigs (Part 1: nine animals in nonrecovery and Part 2: eight animals observed for 8 days after surgery Part 2) received Port Delivery System implant insertion into each eye. The effect of Iridex 810-nm infrared diode laser with varying energy (power or duration) on transscleral pars plana ablation surrounding ocular tissue and postsurgical vitreous hemorrhage was investigated. RESULTS: The most effective laser parameters for transscleral pars plana ablation in mitigating vitreous hemorrhage with no surrounding tissue damage were continuous wave mode, 1,750 mW, 1,000 ms, and 16 spots (eight overlapping spots/sweep applied over two rows) across a 4 mm segment, posterior to the limbus, delivering a total energy of 28 J. Minimal self-limiting scleral hemorrhage was observed with two of the implants, and no vitreous hemorrhage was observed. Microcomputed tomography imaging was consistent with clinical ophthalmic observations. On microscopic observations, no tissue damage was observed at these laser settings. CONCLUSION: This Göttingen minipig model demonstrated a novel application of Iridex laser for transscleral pars plana ablation that streamlines the Port Delivery System implantation surgery.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Shelton A, Schutten M, Fuji RN, et al. TRANSSCLERAL PARS PLANA CHOROID ABLATION USING THE IRIDEX LASER SYSTEM YIELDS IMPROVEMENTS FOR SURGICAL INSERTION OF THE PORT DELIVERY IMPLANT IN A MINIPIG MODEL. Retina. 2025. PMID: 39778117. doi:10.1097/IAE.0000000000004385

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。