文献速递眼底病与葡萄膜炎

超越表面:利用光学相干断层扫描血管成像探究硅油对黄斑脱离型孔源性视网膜脱离黄斑灌注的影响

BEYOND THE SURFACE: Investigating Silicone Oil's Impact on Macular Perfusion in Macula-Off Rhegmatogenous Retinal Detachment by Optical Coherence Tomography Angiography.
PubMed 文献 · Retina · 2025-01-01

本研究纳入50例黄斑脱离型孔源性视网膜脱离患者,比较玻璃体切除联合气体(24眼)或硅油(26眼)填充术后黄斑血管密度。硅油组浅层、深层毛细血管丛及脉络膜毛细血管丛血管密度显著降低,气体组无显著差异。气体组术后最佳矫正视力显著优于硅油组。

要点

  • 硅油填充组浅层、深层毛细血管丛及脉络膜毛细血管丛血管密度显著降低(P<0.05)。
  • 气体填充组各血管密度与对侧眼无显著差异,且术后最佳矫正视力显著优于硅油组(P<0.05)。
  • 两组术后最佳矫正视力均显著改善(P<0.001),但气体组最终视力更佳。

核心结论

  • 硅油填充导致浅层毛细血管丛、深层毛细血管丛及脉络膜毛细血管丛血管密度降低,提示对黄斑灌注可能存在毒性效应。
  • 气体填充获得更优的最佳矫正视力结局并保留血管密度。
  • 作者认为气体填充可能为黄斑脱离型孔源性视网膜脱离提供更好的结局,并认为需进一步研究硅油的潜在机制及仔细选择患者。

研究设计与样本

  • 纳入黄斑脱离型孔源性视网膜脱离并接受玻璃体切除联合气体或硅油填充的患者,气体组24眼,硅油组26眼。
  • 采用光学相干断层扫描血管成像评估最佳矫正视力及浅层毛细血管丛、深层毛细血管丛、脉络膜毛细血管丛血管密度和黄斑无血管区,并与未受累对侧眼比较。

主要发现

  • 共50例患者参与,平均年龄57.9±9.1岁;硅油组26眼,气体组24眼;两组基线特征无显著差异。
  • 硅油组最佳矫正视力从2.00±0.77 logMAR(20/2000 Snellen)改善至0.95±0.52 logMAR(20/178 Snellen)(P<0.001)。
  • 气体组最佳矫正视力从2.12±0.70 logMAR(20/2636 Snellen)改善至0.70±0.55 logMAR(20/100 Snellen)(P<0.001)。
  • 气体组术后最佳矫正视力显著优于硅油组(P<0.05)。
  • 硅油组浅层毛细血管丛、深层毛细血管丛及脉络膜毛细血管丛各象限血管密度显著降低(P<0.05),气体组无显著差异。

临床怎么用

  • 作者认为气体填充可能为黄斑脱离型孔源性视网膜脱离提供更好的结局。
  • 作者认为需进一步研究硅油的潜在机制并仔细选择患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was to compare macular vessel density (VD) in eyes with macula-off rhegmatogenous retinal detachment after vitrectomy with gas or silicone oil (SO) tamponade. METHODS: Patients with macula-off rhegmatogenous retinal detachment who underwent vitrectomy with either gas or SO tamponade were included. Best-corrected visual acuity (BCVA) and VD in superficial and deep retinal capillary plexuses (superficial capillary plexus and deep capillary plexus), choriocapillaris (choriocapillaris plexus), and foveal avascular zone were assessed using optical coherence tomography angiography. Comparisons were made with the unaffected fellow eye. RESULTS: Fifty patients (average age: 57.9 ± 9.1 years) participated, with 26 eyes undergoing SO tamponade and 24 gas tamponade. No significant differences were found in baseline characteristics. Postoperative BCVA significantly improved in both groups. In the SO group, BCVA improved from 2.00 ± 0.77 logarithm of the minimum angle of resolution (20/2000 Snellen) to 0.95 ± 0.52 logarithm of the minimum angle of resolution (20/178 Snellen). In the gas tamponade group, BCVA improved from 2.12 ± 0.70 logarithm of the minimum angle of resolution (20/2636 Snellen) to 0.70 ± 0.55 logarithm of the minimum angle of resolution (20/100 Snellen) ( P < 0.001 for both groups). Moreover, the gas tamponade group achieved significantly better postoperative BCVA compared with the SO group ( P < 0.05). The silicone oil tamponade group exhibited significantly lower VD in superficial capillary plexus, deep capillary plexus, and choriocapillaris plexus quadrants ( P < 0.05), while gas tamponade showed no significant differences. CONCLUSION: This study reveals a decrease in VD in superficial capillary plexus, deep capillary plexus, and choriocapillaris plexus induced by SO tamponade, suggesting potential toxic effects on macular perfusion. Gas tamponade resulted in superior BCVA outcomes and preserved VD. Further investigation into SO's underlying mechanisms and careful patient selection is warranted. Gas tamponade may offer better outcomes for macula-off rhegmatogenous retinal detachment.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Ozal E, Guler MS, Karapapak M, et al. BEYOND THE SURFACE: Investigating Silicone Oil's Impact on Macular Perfusion in Macula-Off Rhegmatogenous Retinal Detachment by Optical Coherence Tomography Angiography. Retina. 2025. PMID: 39652833. doi:10.1097/IAE.0000000000004364

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。