光学相干断层扫描评估孔源性视网膜脱离中的脉络膜上腔:对未来潜在治疗干预的意义
该研究对90例原发性孔源性视网膜脱离(RRD)患者进行回顾性事后分析,用扫频源光学相干断层扫描评估脉络膜上腔(SCS)的存在与厚度,并与对侧眼比较。RRD眼中SCS可见比例为31.6%(24/76),对侧眼为28.3%(13/46),RRD眼各SCS厚度测量值均显著大于对侧眼。作者认为RRD眼中SCS显著充盈,可能有助于经SCS治疗如脉络膜上腔黏合固定或药物治疗。
要点
- RRD眼中SCS可见比例为31.6%(24/76),对侧眼为28.3%(13/46)。
- RRD眼SCS最厚处均值67.0 µm(SD 25.9),对侧眼47.0 µm(SD 41.7),差异有统计学意义。
- RRD眼SCS最薄处均值33.8 µm(SD 11.1),平均厚度均值50.0 µm(SD 16.8),均显著大于对侧眼。
核心结论
- 在RRD中,SCS作为重要的液体储库,受眼内静水压和胶体渗透压动态变化影响。
- RRD眼较对侧眼存在显著的SCS充盈,可能有助于经SCS治疗如脉络膜上腔黏合固定或其他药物干预。
研究设计与样本
- 对90例连续的原发性孔源性视网膜脱离患者进行事后分析。
- 使用扫频源光学相干断层扫描,对基线扫描评估SCS的存在与厚度,并对可用的对侧眼扫描进行对比评估。
主要发现
- RRD扫描可评估者中SCS可见比例为31.6%(24/76)。
- RRD眼SCS最厚处均值67.0 µm(SD 25.9),最薄处均值33.8 µm(SD 11.1),平均厚度均值50.0 µm(SD 16.8)。
- 对侧眼扫描可评估者中SCS可见比例为28.3%(13/46),最厚处均值47.0 µm(SD 41.7),最薄处均值25.2 µm(SD 27.6),平均厚度均值35.8 µm(SD 31.4)。
- RRD眼与对侧眼在所有SCS厚度测量值上均存在统计学显著差异。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To comprehensively investigate the suprachoroidal space (SCS) in the context of rhegmatogenous retinal detachment (RRD) using swept-source optical coherence tomography. METHODS: We conducted a post hoc analysis of 90 consecutive patients with a primary RRD. Baseline swept-source optical coherence tomography scans were graded for the presence and thickness of SCS. Available scans of the fellow eye were graded for comparison. RESULTS: Suprachoroidal space was visible in 31.6% (24/76) of gradable RRD scans, with a mean thickest location measuring 67.0 µ m (SD 25.9), mean thinnest location of 33.8 µ m (SD 11.1), and mean average thickness of 50.0 µ m (SD 16.8). In addition, the SCS was detectable in 28.3% (13/46) of available fellow eye scans, with a mean thickest location measuring 47.0 µ m (SD 41.7), thinnest location of 25.2 µ m (SD 27.6), and mean average thickness of 35.8 µ m (SD 31.4). A statistically significant difference was found between RRD and fellow eyes in all measurements of SCS thickness. CONCLUSION: In RRD, the SCS serves as a crucial fluid reservoir influenced by dynamic shifts in intraocular hydrostatic and oncotic pressures. We found significant SCS engorgement in RRD eyes compared with fellow eyes, which may facilitate intra-SCS therapies such as suprachoroidal viscopexy or other pharmacologic interventions.
引用
- Jung KL, Pecaku A, Demian S, et al. SUPRACHOROIDAL SPACE IN RHEGMATOGENOUS RETINAL DETACHMENT ASSESSED WITH OPTICAL COHERENCE TOMOGRAPHY: Implications for Potential Future Therapeutic Interventions. Retina. 2025. PMID: 39622245. doi:10.1097/IAE.0000000000004349
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。