本研究基于新加坡华人眼研究,利用深度学习算法获取前节光学相干断层扫描(ASOCT)的前房深度(ACD)、面积(ACA)、宽度(ACW)及晶状体拱高(LV)的规范分布,并对80%开放眼和80%房角关闭眼进行多变量逻辑回归,在20%开放眼和20%房角关闭眼中评估诊断性能。结果显示ACD第20百分位和LV第85百分位单独或联合使用可检测原发性房角关闭疾病(PACD),联合时灵敏度88.68%、特异度88.85%。

要点

  • ACD、ACA和ACW随年龄增长而减小,女性更小;LV则相反(所有p<0.022)。
  • ACD第20百分位和LV第85百分位检测PACD的平衡准确率分别为84.4%和84.2%。
  • 联合ACD第20百分位和LV第85百分位检测PACD的灵敏度88.68%、特异度88.85%。

核心结论

  • 前房参数随年龄和性别变化,ACD第20百分位和LV第85百分位可单独或联合用于检测PACD。

研究设计与样本

  • 纳入新加坡华人眼研究中具有ASOCT扫描的受试者,排除有眼部手术、激光治疗及眼外伤的眼。
  • 使用深度学习算法获取Visante ASOCT测量值,用80%开放眼建立规范分布。
  • 对80%开放眼和80%房角关闭眼进行多变量逻辑回归,用20%开放眼和20%房角关闭眼评估诊断性能。
  • 共纳入2157眼(1853只开放眼;304只房角关闭眼)进行分析。

主要发现

  • ACD、ACA和ACW随年龄增长而减小,女性更小;LV则相反(所有p<0.022)。
  • ACD第20百分位检测PACD的平衡准确率为84.4%,LV第85百分位为84.2%。
  • 联合ACD第20百分位和LV第85百分位检测PACD的灵敏度为88.68%、特异度为88.85%。
  • 多变量回归模型(包含ACA、房角开放距离、LV、虹膜面积)的灵敏度为88.33%、特异度为83.75%。

关键数值与推荐

  • PACD定义为≥180°后部小梁网关闭。
  • ACD第20百分位和LV第85百分位联合检测PACD的灵敏度88.68%、特异度88.85%。

临床怎么用

  • 在缺乏更复杂分类算法的情况下,ACD第20百分位和LV第85百分位值可单独或联合用于检测PACD。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/ AIMS: The lack of context for anterior segment optical coherence tomography (ASOCT) measurements impedes its clinical utility. We established the normative distribution of anterior chamber depth (ACD), area (ACA) and width (ACW) and lens vault (LV), and applied percentile cut-offs to detect primary angle closure disease (PACD; ≥180° posterior trabecular meshwork occluded). METHODS: We included subjects from the Singapore Chinese Eye Study with ASOCT scans. Eyes with ocular surgery or laser procedures, and ocular trauma were excluded. A deep-learning algorithm was used to obtain Visante ASOCT (Carl Zeiss Meditec, USA) measurements. Normative distribution was established using 80% of eyes with open angles. Multivariable logistic regression was performed on 80% open and 80% angle closure eyes. Diagnostic performance was evaluated using 20% open and 20% angle closure eyes. RESULTS: We included 2157 eyes (1853 open angles; 304 angle closure) for analysis. ACD, ACA and ACW decreased with age and were smaller in females, and vice versa for LV (all p<0.022). ACD 20th percentile and LV 85th percentile had a balanced accuracy of 84.4% and 84.2% in detecting PACD, respectively. When combined, ACD 20th and LV 85th percentile had 88.68% sensitivity and 88.85% specificity in detecting PACD as compared with a multivariable regression model (ACA, angle opening distance, LV, iris area) with 88.33% sensitivity and 83.75% specificity. CONCLUSION: Anterior chamber parameters varied with age and gender. The ACD 20th and LV 85th percentile values may be used in silos or in combination to detect PACD in the absence of more sophisticated classification algorithms.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。