厚度速度进展指数:用于圆锥角膜检测的机器学习方法
这项回顾性研究纳入349例患者349只眼,基于Galilei双Scheimpflug-Placido系统角膜厚度进展图提取6个参数,构建机器学习指数(厚度速度进展指数)。实验1中随机森林模型区分正常与圆锥角膜准确率100%、AUROC 1.00;实验2区分正常、疑似与圆锥角膜总体准确率91%;实验3区分正常、地形/断层正常、边界对侧眼与圆锥角膜准确率87%。作者结论认为仅基于厚度数据的机器学习算法能以合理准确度区分正常角膜与圆锥角膜及疑似圆锥角膜。
要点
- 厚度速度进展指数基于角膜厚度进展图的6个参数构建,仅用厚度数据。
- 实验1中随机森林区分正常与圆锥角膜准确率100%,AUROC均为1.00。
- 实验2总体准确率91%,正常、疑似、圆锥角膜AUROC分别为0.93、0.83、0.99。
核心结论
- 仅基于厚度数据的机器学习算法如厚度速度进展指数能以合理准确度区分正常角膜与圆锥角膜及疑似圆锥角膜。
研究设计与样本
- 回顾性研究,纳入349例患者349只眼,含正常、确诊圆锥角膜和疑似圆锥角膜。
- 疑似圆锥角膜包括不对称圆锥角膜患者中地形/断层正常眼和边界对侧眼。
- 从Galilei双Scheimpflug-Placido系统角膜厚度进展图提取6个参数输入机器学习算法。
- 采用5折交叉验证、对7种机器学习算法随机搜索训练,选择最佳模型和超参数。
主要发现
- 共纳入正常眼133只、圆锥角膜眼141只、疑似圆锥角膜眼75只(其中地形/断层正常眼34只、边界对侧眼41只)。
- 实验1(正常与圆锥角膜)最佳模型为随机森林,正常组和圆锥角膜组准确率均为100%、AUROC均为1.00。
- 实验2(正常、疑似与圆锥角膜)总体准确率91%,检测正常、疑似、圆锥角膜的AUROC分别为0.93、0.83、0.99。
- 实验3(正常、地形/断层正常、边界对侧眼与圆锥角膜)准确率87%,四类AUROC分别为0.91、0.60、0.77、0.94。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To develop and validate a pachymetry-based machine learning (ML) index for differentiating keratoconus, keratoconus suspect, and normal corneas. DESIGN: Development and validation of an ML diagnostic algorithm. METHODS: This retrospective study included 349 eyes of 349 patients with normal, frank keratoconus (KC), and KC suspect (KCS) corneas. KCS corneas included topographically/tomographically normal (TNF) and borderline fellow eyes (TBF) of patients with asymmetric KC. Six parameters were derived from the corneal thickness progression map on the Galilei Dual Scheimpflug-Placido system and fed into a machine-learning algorithm to create the Thickness Speed Progression Index. The model was trained with 5-fold cross-validation using a random search over 7 different ML algorithms, and the best model and hyperparameters were selected. RESULTS: A total of 133 normal eyes, 141 KC eyes, and 75 KCS eyes, subdivided into 34 TNF and 41 TBF eyes, were included. In experiment 1 (normal and KC), the best model (Random Forest) achieved an accuracy of 100% and area under the receiver operating characteristic (AUROC) of 1.00 for both normal and KC groups. In experiment 2 (normal, KCS, and KC), the model achieved an overall accuracy of 91%, and AUROC curves of 0.93, 0.83, and 0.99 in detecting normal, KCS, and KC corneas respectively. In experiment 3 (normal, TNF, TBF, and KC), the model achieved an accuracy of 87% with AUROC curves of 0.91, 0.60, 0.77, and 0.94 for normal, TNF, TBF, and KC corneas, respectively. CONCLUSIONS: Using data solely based on pachymetry, ML algorithms such as the Thickness Speed Progression Index are able to discriminate normal corneas from KC and KCSs corneas with reasonable accuracy.
引用
- Awwad ST, Hammoud B, Assaf JF, et al. Thickness Speed Progression Index: Machine Learning Approach for Keratoconus Detection. Am J Ophthalmol. 2024. PMID: 39608740. doi:10.1016/j.ajo.2024.11.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。