文献速递角膜与眼表疾病

确定角膜交联后角膜硬化与组织脱水之间的关系

Determining the Relationship Between Corneal Stiffening and Tissue Dehydration After Corneal Cross-Linking.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2024-01-01

研究将83个猪角膜纽扣分为标准交联(S-CXL)、加速交联(A-CXL)和未照射核黄素对照三组,用动态力学分析测量杨氏模量,并建立双相材料模型提取固体组织网络模量。结果显示S-CXL后杨氏模量增加四倍、A-CXL增加三倍,但水合度H下降;校正H后固体组织网络模量仅分别增加1.8倍和1.5倍。作者结论认为不考虑水合度会高估交联引起的硬化效应。

要点

  • S-CXL后杨氏模量增加四倍(0.72 ± 0.1 MPa),A-CXL增加三倍(0.53 ± 0.12 MPa),对照组为0.17 ± 0.045 MPa。
  • 水合度H从对照组4.07 ± 0.35降至S-CXL后2.06 ± 0.2、A-CXL后2.79 ± 0.12。
  • 校正水合度后固体组织网络模量仅S-CXL增加1.8倍(2.25 MPa)、A-CXL增加1.5倍(1.85 MPa),对照组为1.22 MPa。

核心结论

  • 角膜组织水合度变化显著影响交联后机械测试测得的角膜刚度,不考虑水合度会高估交联的硬化效应。

研究设计与样本

  • 研究将83个猪角膜纽扣分为标准交联(S-CXL)、加速交联(A-CXL)和未照射核黄素对照(nonirradiated riboflavin-only)三组。
  • 样本经水合或脱水调节水合度H后行动态力学分析压缩测试测量杨氏模量E,并在不同H下将角膜建模为双相材料以提取固体组织网络模量。
  • 用共聚焦反射显微镜(CRM)表征深度依赖的组织厚度并与角膜水合度做相关分析。

主要发现

  • S-CXL后杨氏模量增加四倍(0.72 ± 0.1 MPa),A-CXL后增加三倍(0.53 ± 0.12 MPa),对照组为0.17 ± 0.045 MPa。
  • 水合度H从对照组4.07 ± 0.35降至S-CXL后2.06 ± 0.2、A-CXL后2.79 ± 0.12。
  • 经H调节和双相力学建模后,角膜固体组织网络杨氏模量仅S-CXL后增加1.8倍(2.25 MPa)、A-CXL后增加1.5倍(1.85 MPa),对照组为1.22 MPa。
  • CRM显示角膜组织总厚度与H呈线性相关,符合预期;整个角膜纽扣中未观察到水合诱导厚度变化有明显深度依赖性。

关键数值与推荐

  • S-CXL后杨氏模量0.72 ± 0.1 MPa、A-CXL后0.53 ± 0.12 MPa、对照组0.17 ± 0.045 MPa。
  • 水合度H:对照组4.07 ± 0.35、S-CXL后2.06 ± 0.2、A-CXL后2.79 ± 0.12。
  • 校正H后固体组织网络模量:S-CXL 2.25 MPa(增加1.8倍)、A-CXL 1.85 MPa(增加1.5倍)、对照组1.22 MPa。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To quantify corneal cross-linking (CXL)-induced stiffening via mechanical testing to estimate the impact of changes in hydration levels (H) and evaluate depth-dependent tissue hydration after CXL. METHODS: Eighty-three porcine corneal buttons were divided into three groups: Standard protocol CXL (S-CXL), accelerated CXL (A-CXL), and untreated (nonirradiated riboflavin-only) controls. Samples were hydrated or dehydrated to modulate H and dynamic mechanical analyzer compression tests were performed to measure Young's modulus (E). To extract the solid tissue network modulus, the cornea was modeled as a biphasic material after measuring E at different H. Corneal hydration was correlated with depth-dependent tissue thickness characterized by confocal reflection microscopy (CRM). RESULTS: Young's modulus increased fourfold after S-CXL (0.72 ± 0.1 MPa) and threefold after A-CXL E (0.53 ± 0.12 MPa) versus controls (0.17 ± 0.045 MPa). However, H decreased from 4.07 ± 0.35 in controls to 2.06 ± 0.2 after S-CXL and 2.79 ± 0.12 after A-CXL. After H modulation and biphasic mechanical modeling, Young's modulus for corneal solid tissue network showed only a 1.8-fold increase after S-CXL (2.25 MPa) and 1.5-fold increase after A-CXL (1.85 MPa) versus controls (1.22 MPa). With CRM, the overall thickness of the corneal tissue was found to linearly correlate to hydration H as expected. No appreciable depth dependence of hydration-induced thickness changes throughout the corneal buttons were observed. CONCLUSIONS: Corneal tissue hydration changes significantly impact measured corneal stiffness after CXL using mechanical testing. Not considering H leads to major overestimation of the stiffening effect of the CXL procedure. Depth-dependence of corneal thickness because of changing hydration is strongly dependent on the integrity of the tissue.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Rodríguez-López R, Webb JN, Erdi M, et al. Determining the Relationship Between Corneal Stiffening and Tissue Dehydration After Corneal Cross-Linking. Invest Ophthalmol Vis Sci. 2024. PMID: 39504051. doi:10.1167/iovs.65.13.14

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。