文献速递白内障与屈光手术

比较先进单焦与非衍射扩展焦深人工晶状体采用微单视方案的视觉表现

Comparing an Advanced Monofocal With a Non-diffractive Extended Depth of Focus Intraocular Lens Using a Mini-Monovision Approach.
PubMed 文献 · Am J Ophthalmol · 2024-10-28

单中心随机对照双盲研究纳入48例(96眼)双眼年龄相关性白内障患者,比较先进单焦IOL RAO200E与非衍射扩展焦深IOL DFT015在微单视方案下的视觉表现。术后3个月双眼远中近视力无显著差异,DFT015在主导眼单眼DCIVA、DCNVA及主导眼和非主导眼UNVA更优,RAO200E组光晕更小,DFT015组在-2.5、-2.0、-1D离焦时矫正离焦曲线更优。

要点

  • 双眼CDVA、66cm DCIVA、40cm DCNVA在RAO200E与DFT015组间无显著差异。
  • DFT015组主导眼单眼DCIVA、DCNVA及主导眼和非主导眼UNVA显著优于RAO200E组。
  • RAO200E组光晕尺寸显著更小,DFT015组在-2.5、-2.0、-1D离焦时矫正离焦曲线显著更优。

核心结论

  • 在微单视方案下,先进单焦IOL RAO200E与非衍射扩展焦深IOL DFT015的双眼矫正或非矫正远、中、近视力无显著差异。

研究设计与样本

  • 单中心、随机、对照、双盲研究,共纳入48例(96眼)双眼年龄相关性白内障患者。
  • 一组双眼植入先进单焦IOL RAO200E(RayOne EMV;Rayner),另一组双眼植入非衍射扩展焦深IOL DFT015(Acrysof IQ Vivity;Alcon)。
  • 两组目标屈光均为微单视,术后3个月比较单眼和双眼矫正及非矫正远、中、近视力、对比敏感度、双眼离焦曲线、光晕测量及视觉质量问卷评分。

主要发现

  • 双眼平均CDVA、66cm DCIVA、40cm DCNVA:RAO200E组分别为-0.10±0.10、0.15±0.11、0.32±0.16 logMAR,DFT015组分别为-0.10±0.10、0.12±0.10、0.27±0.16 logMAR,组间无显著差异。
  • 主导眼单眼DCIVA和DCNVA:RAO200E组分别为0.28±0.14、0.48±0.22 logMAR,DFT015组分别为0.14±0.10(P = .023)、0.35±0.16(P = .008)logMAR,差异显著。
  • 主导眼和非主导眼单眼UNVA:RAO200E组分别为0.46±0.21、0.41±0.20 logMAR,DFT015组分别为0.30±0.14(P = .001)、0.21±0.10(P = .003)logMAR,差异显著。
  • RAO200E组光晕尺寸显著更小;DFT015组在-2.5D(P = .031)、-2.0D(P = .03)、-1D(P = .03)离焦时矫正离焦曲线显著更优。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare interindividual differences in visual performance of an advanced monofocal with a nondiffractive extended depth of focus intraocular lens (IOL) using a mini-monovision approach. DESIGN: Single-center, randomized, controlled, double-masked study. METHODS: In total, 48 patients (96 eyes) with bilateral age-related cataract were enrolled. One group received an advanced monofocal IOL RAO200E (RayOne EMV; Rayner) and the other group a non-diffractive extended depth of focus IOL DFT015 (Acrysof IQ Vivity; Alcon) in both eyes. Target refraction for both groups was mini-monovision. After 3 months, monocular and binocular distance corrected and uncorrected distance (CDVA/UDVA), intermediate (DCIVA/UIVA), and near visual acuity (DCNVA/UNVA); contrast sensitivity; binocular defocus curves; halometry; and Quality of Vision questionnaire scores were compared. RESULTS: Binocular mean CDVA, DCIVA at 66 cm, and DCNVA at 40 cm were -0.10±0.10, 0.15±0.11, and 0.32±0.16 logMAR for the RAO200E and -0.10±0.10, 0.12±0.10, and 0.27±0.16 logMAR for the DFT015, respectively, with no significant difference. A significant difference could be shown for the dominant eye in monocular DCIVA and DCNVA and for the dominant and nondominant eye in monocular UNVA, with 0.28±0.14, 0.48±0.22, 0.46±0.21, and 0.41±0.20 logMAR for the RAO200E and 0.14±0.10 (P = .023), 0.35±0.16 (P = .008), 0.30±0.14 (P = .001), and 0.21±0.10 (P = .003) logMAR for the DFT015, respectively. Significantly smaller halo size in the RAO200E group and significantly better distance-corrected defocus curve at -2.5 (P = .031), -2.0 (P = .03), and -1 diopters (P = .03) of defocus in the DFT015 group could be shown. CONCLUSIONS: Distance corrected or uncorrected binocular visual acuity for far, intermediate, and near distance between the advanced monofocal IOL RAO200E and the non-diffractive extended depth of focus IOL DFT015, when compared in a mini-monovision setting, showed no significant differences.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Zeilinger J, Kronschläger M, Schlatter A, et al. Comparing an Advanced Monofocal With a Non-diffractive Extended Depth of Focus Intraocular Lens Using a Mini-Monovision Approach. Am J Ophthalmol. 2024. PMID: 39490721. doi:10.1016/j.ajo.2024.10.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。