文献速递角膜与眼表疾病白内障与屈光手术

影响Fuchs角膜内皮营养不良患眼行后弹力层内皮角膜移植三联手术后屈光误差的因素分析

Analysis of factors influencing refractive error in Fuchs eyes undergoing Descemet membrane endothelial keratoplasty triple procedure.
PubMed 文献 · Br J Ophthalmol · 2025-03-20

回顾性队列研究纳入90只Fuchs角膜内皮营养不良(FECD)患眼,均于Wilmer Eye Institute接受无并发症的后弹力层内皮角膜移植(DMEK)三联手术。比较Barrett Universal II(BU2)、Hoffer QST、Haigis-L(HL)和Barrett True K(BTK)公式的预测误差,发现所有公式均呈远视误差,HL平均误差最低(0.24 D±0.97 D),BU2最高(0.94 D±0.97 D)。结论认为角膜水肿的断层特征数量有助于识别人工晶状体(IOL)计算误差较高的患眼。

要点

  • 所有公式在DMEK三联手术后均呈远视平均误差,HL最低为0.24 D(±0.97 D),BU2最高为0.94 D(±0.97 D)。
  • BU2和Hoffer QST公式中,每增加一个角膜水肿断层特征,平均远视误差增加0.38 D。
  • BTK和HL公式中,每增加一个角膜水肿断层特征,平均误差增加0.35 D(p<0.001)。

核心结论

  • 角膜水肿的断层特征数量可用于识别FECD患眼行DMEK三联手术时IOL计算误差较高的患眼。

研究设计与样本

  • 回顾性队列研究,纳入90只FECD患眼,均于Wilmer Eye Institute接受无并发症的DMEK三联手术(DMEK联合白内障摘除及IOL植入)。

主要发现

  • 所有公式均产生远视平均误差,HL平均误差最低为0.24 D(±0.97 D),BU2平均误差最高为0.94 D(±0.97 D)。
  • BU2和Hoffer QST公式中,每增加一个角膜水肿断层特征,平均远视误差增加0.38 D。
  • BTK和HL公式中,每增加一个角膜水肿断层特征,平均误差增加0.35 D(p<0.001)。

关键数值与推荐

  • BU2、Hoffer QST、HL和BTK公式的平均误差(±SD)分别为0.94 D(±0.97 D)、原文未报告、0.24 D(±0.97 D)、原文未报告。
  • BU2和Hoffer QST公式每增加一个角膜水肿断层特征,平均远视误差增加0.38 D。
  • BTK和HL公式每增加一个角膜水肿断层特征,平均误差增加0.35 D(p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the accuracy of current intraocular lens (IOL) formulas and identify factors influencing mean error in eyes undergoing Descemet membrane endothelial keratoplasty (DMEK) triple procedure, that is, DMEK combined with cataract extraction and IOL placement for concurrent Fuchs endothelial corneal dystrophy (FECD) and cataracts. DESIGN: Retrospective cohort study. SUBJECTS: 90 eyes with FECD undergoing uncomplicated DMEK triple procedure at Wilmer Eye Institute. METHODS: We analysed tomographic features of oedema, including loss of regular isopachs, displacement of the thinnest point of the cornea and the presence of posterior surface depression, and assessed the correlation with the prediction error. MAIN OUTCOME MEASURES: We compared the mean error (±SD) for the Barrett Universal II (BU2), Hoffer QST, Haigis-L (HL) and Barrett True K (BTK) formulas and the percentage of eyes within 0.25, 0.5 and 1 diopter (D) of error. RESULTS: All formulas resulted in a mean hyperopic error, with the HL having the lowest mean error of 0.24 D (±0.97 D) and BU2 having the highest ME of 0.94 D (±0.97 D). For each additional tomographic feature of corneal oedema in the BU2 and Hoffer QST formulas, the mean hyperopic error increased by 0.38 D. For the BTK and HL formulas, the mean error increased by 0.35 D (p<0.001). CONCLUSION: The number of tomographic features of oedema can be useful in identifying eyes with higher errors in IOL calculation when performing the DMEK triple procedure for FECD.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Kuo JCL, Cho KJ, Ali M, et al. Analysis of factors influencing refractive error in Fuchs eyes undergoing Descemet membrane endothelial keratoplasty triple procedure. Br J Ophthalmol. 2025. PMID: 39401867. doi:10.1136/bjo-2024-325967

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。