应用高分辨率自适应光学成像比较黄斑裂孔手术前后的光感受器镶嵌
前瞻性病例系列纳入9例特发性全层黄斑裂孔患者共18眼,在玻璃体切除术前及术后3个月行自适应光学眼底成像,测量2°和4°偏心率的视锥细胞密度、规则性、离散度和间距并进行比较。结果显示2°处术后视锥细胞密度显著降低、间距和离散度显著增加,规则性变化无统计学意义;4°处各指标均无显著变化。
要点
- 2°偏心率处术后视锥细胞密度较术前显著降低(P=.0004),间距和离散度显著增加(P=.0002、P=.013)。
- 2°处规则性术后变化无统计学意义(P=.054)。
- 4°偏心率处术前术后各指标均无显著变化。
核心结论
- 自适应光学成像可对黄斑裂孔患者玻璃体切除术前后的光感受器镶嵌进行定量评估。
- 2°偏心率处存在与黄斑裂孔相关的术前术后光感受器镶嵌显著变化。
- 自适应光学成像可用于术后光感受器重塑过程的高分辨率研究,可能有助于更全面评估手术结局。
研究设计与样本
- 前瞻性病例系列,纳入加拿大多伦多Kensington Eye Institute诊断为黄斑裂孔并接受玻璃体切除术的患者。
- 排除标准为继发性黄斑裂孔、高度近视(眼轴长度>26.5 mm)、阻碍光学相干断层扫描或自适应光学成像的屈光介质混浊、除白内障摘除外的既往眼内手术。
- 使用自适应光学眼底相机(Imagine Eyes,RTX1)在术前及成功修复黄斑裂孔后3个月对双眼成像。
主要发现
- 共纳入9例患者18眼。2°处术前与术后平均(标准误)视锥细胞密度为14,612 ± 3003 vs 12,280 ± 4632 个光感受器/mm2(95%CI=-2413至-702),P=.0004。
- 2°处规则性为88% ± 7% vs 84% ± 12%(95%CI=-4.67至0.04),P=.054。
- 2°处离散度为19% ± 6% vs 23% ± 10%(95%CI=0.5至4.24),P=.013;间距为9 ± 1微米 vs 10 ± 2微米(95%CI=0.40至1.27),P=.0002。
- 4°处视锥细胞密度为13,377 ± 4339 vs 12,770 ± 4391 个光感受器/mm2(95%CI=-1368至252),P=.176。
- 4°处规则性为87% ± 9% vs 86% ± 12%(95%CI=-4.65至0.08),P=.74;离散度为20% ± 8% vs 20% ± 9%(95%CI=-2.11至1.5),P=.74;间距为10 ± 2微米 vs 10 ± 3微米(95%CI=-0.23至0.58),P=.39。
关键数值与推荐
- 在2°偏心率处测量视锥细胞密度、规则性、离散度和间距,于上、下、鼻、颞4个象限进行,并与术前值比较。
- 在4°偏心率处测量视锥细胞密度、规则性、离散度和间距,于上、下、鼻、颞4个象限进行,并与术前值比较。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the photoreceptor mosaic in patients with idiopathic full-thickness macular hole (MH) before and after pars plana vitrectomy (PPV) with adaptive optics enhanced retinal imaging (AO). DESIGN: Prospective case series. METHODS: Prospective cohort study of patients who presented at the Kensington Eye Institute, Toronto, Canada with a diagnosis of MH treated with PPV. EXCLUSION CRITERIA: secondary MH, high myopia (axial length >26.5 mm), media opacity precluding optical coherence tomography or AO imaging, previous intraocular surgery except for cataract extraction. Imaging using an AO fundus camera (Imagine Eyes, RTX1) was performed preoperatively and 3 months following successful MH repair in both eyes. Cone density (CD), regularity, dispersion, and spacing were measured at 2° and/or 4° of eccentricity in 4 quadrants (superior, inferior, nasal, and temporal) with pre- and postoperative values compared. RESULTS: We included 18 eyes of 9 patients. At 2° there was significant reduction in CD and increase in spacing and dispersion and a nonsignificant change in regularity postoperatively. Comparison between preoperative and postoperative measurements at 2° mean (standard error) were: CD: 14,612 ± 3003 and 12,280 ± 4632 photoreceptors/mm2 (95% CIs = -2413 to -702) P = .0004, regularity: 88% ± 7% and 84% ± 12% (95% CIs = -4.67 to 0.04) P = .054, dispersion: 19% ± 6% and 23% ± 10% (95% CIs = 0.5-4.24) P = .013, spacing: 9 ± 1 microns and 10 ± 2 microns (95% CIs = 0.40-1.27) P = .0002; at 4° was: CD: 13,377 ± 4339 and 12,770 ± 4391 photoreceptors/mm2 (95% CIs = -1368 to 252) P = .176, regularity:87% ± 9% and 86% ± 12% (95% CIs = -4.65 to 0.08) P = .74, dispersion: 20% ± 8% and 20% ±9% (95% CIs = -2.11 to 1.5) P = .74, spacing:10 ± 2 microns and 10 ± 3 microns (95% CIs = -0.23 to 0.58) P = .39. CONCLUSIONS: AO imaging allows quantitative assessment of the photoreceptor mosaic pre- and post-PPV in patients with MH. There was a significant change to the photoreceptor mosaic related to the MH at 2° pre- and postoperatively. AO imaging enables high-resolution investigation of the photoreceptor remodeling process following surgery, which may allow for a more thorough assessment of surgical outcomes.
引用
- Oquendo PL, Wright T, Naidu SC, et al. Comparison of the Photoreceptor Mosaic Before and After Macular Hole Surgery With High-Resolution Adaptive Optics Imaging. Am J Ophthalmol. 2024. PMID: 39455037. doi:10.1016/j.ajo.2024.10.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。