健康眼、疑似青光眼及确诊青光眼中黄斑与视神经乳头OCTA血管密度纵向丢失
本研究纳入健康眼36只、疑似青光眼57只和原发性开角型青光眼79只,随访至少2年、完成4次黄斑及视神经乳头OCTA成像。各组黄斑全图像血管密度和视神经乳头全图像毛细血管密度年丢失率均与零有差异(p<0.05);视神经乳头毛细血管密度丢失率在各诊断组间不同(p<0.001),黄斑血管密度从健康眼到疑似青光眼未见增加(p=0.167)。基线视野平均偏差与两种丢失率均相关(p<0.05),与视神经乳头毛细血管密度丢失率相关略强(R²=0.27 vs 0.16)。
要点
- 健康、疑似青光眼与开角型青光眼各组黄斑血管密度和视神经乳头毛细血管密度年丢失率均与零有差异(p<0.05)。
- 视神经乳头毛细血管密度丢失率在各诊断组间不同(p<0.001),黄斑血管密度从健康眼到疑似青光眼未见增加(p=0.167)。
- 基线视野平均偏差与黄斑血管密度及视神经乳头毛细血管密度丢失率均相关(p<0.05),后者略强(R²=0.27 vs 0.16)。
核心结论
- 青光眼中视神经乳头微血管丢失早于黄斑。
- 视神经乳头血管密度丢失与基线视野的关联略强于黄斑血管密度。
- 作者认为用OCTA观察视神经乳头血管密度丢失可能有助于监测早期青光眼,并应通过未来更大规模研究确认。
研究设计与样本
- 来自青光眼诊断创新研究(Diagnostic Innovations in Glaucoma Study)的健康眼、疑似青光眼眼和原发性开角型青光眼眼。
- 纳入随访至少2年且完成4次黄斑/视神经乳头OCTA成像的眼。
- 健康组36只眼(25名受试者)、疑似青光眼组57只眼(38名受试者)、原发性开角型青光眼组79只眼(50名受试者)。
- 采用联合混合效应模型计算各诊断组黄斑全图像血管密度和视神经乳头全图像毛细血管密度的变化率,并通过两两比较检验组间差异。
- 在原发性开角型青光眼眼中评估基线24-2视野平均偏差与两种变化率的关系。
主要发现
- 各组黄斑全图像血管密度丢失率范围为-0.72至-0.92%/年,视神经乳头全图像毛细血管密度丢失率范围为-0.28至-0.66%/年,均与零有差异(p<0.05)。
- 视神经乳头毛细血管密度丢失率在各诊断组间均不同(p<0.001)。
- 黄斑血管密度变化率从健康眼到疑似青光眼未见增加(p=0.167)。
- 基线视野平均偏差与黄斑血管密度及视神经乳头毛细血管密度丢失率均呈显著但中等程度相关(p<0.05),与视神经乳头毛细血管密度变化率的相关略强(R²=0.27 vs 0.16)。
关键数值与推荐
- 黄斑全图像血管密度丢失率范围为-0.72至-0.92%/年,各组均与零有差异(p<0.05)。
- 视神经乳头全图像毛细血管密度丢失率范围为-0.28至-0.66%/年,各组均与零有差异(p<0.05)。
- 视神经乳头毛细血管密度丢失率组间比较p<0.001。
- 黄斑血管密度变化率健康眼与疑似青光眼比较p=0.167。
- 基线视野平均偏差与黄斑血管密度丢失率相关R²=0.16、与视神经乳头毛细血管密度丢失率相关R²=0.27(p<0.05)。
临床怎么用
- 作者认为用OCTA观察视神经乳头血管密度丢失可能有助于监测早期青光眼,该结论应通过未来更大规模研究确认。
局限性
- 作者指出结论应通过未来更大规模研究确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: To examine longitudinal optical coherence tomography angiography (OCTA) changes in macula and optic nerve head (ONH) in healthy, glaucoma suspect (GS) and primary open-angle glaucoma (POAG) eyes. METHODS: Healthy, GS and POAG eyes from Diagnostic Innovations in Glaucoma Study with ≥2 years follow-up and four visits of macular/ONH OCTA imaging were included. Rates of macular wiVD (whole-image vessel density) and ONH wiCD (whole-image capillary density) changes were calculated for each diagnosis group using join mixed-effect modelling. Differences in wiVD/wiCD change rates across diagnoses were examined through pairwise comparison. Relationships of baseline 24-2 visual field (VF) mean deviation (MD) with wiVD/wiCD change rates were evaluated for POAG eyes. RESULTS: There were 36, 57 and 79 eyes (25, 38 and 50 subjects) in healthy, GS and POAG groups, respectively. Rates of wiVD (range:-0.72 to -0.92 %/year) and wiCD (range:-0.28 to -0.66 %/year) loss were different from zero in all groups (p<0.05). The rates of wiCD loss differed across all diagnosis groups (p<0.001), while wiVD change rates did not increase when comparing healthy to GS eyes (p=0.167). Baseline VF MD showed a significant but modest correlation with the rates of both wiVD and wiCD loss (p<0.05), and the correlation with wiCD change rate was slightly stronger (R2=0.27 vs 0.16). CONCLUSIONS: In glaucoma, there is earlier microvasculature loss in the ONH than in the macula. Moreover, ONH VD loss shows a slightly stronger association with baseline VF than macular VD. Observing ONH VD loss with OCTA may help to monitor early glaucoma, which should be confirmed by future larger studies.
引用
- Wu JH, Moghimi S, Nishida T, et al. Longitudinal OCTA vessel density loss in macula and optic nerve head in healthy, glaucoma suspect and established glaucoma eyes. Br J Ophthalmol. 2025. PMID: 39467642. doi:10.1136/bjo-2024-325746
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。