文献速递眼底病与葡萄膜炎小儿眼科与斜弱视

早产儿视网膜病变纵向评估(LONGROP)研究:阅片时间与对比能力对变化检测的影响

Longitudinal Assessment of Retinopathy of Prematurity (LONGROP) Study: Impacts of Viewing Time and Ability to Compare on Detection of Change.
PubMed 文献 · Am J Ophthalmol · 2024-10-24

该前瞻性可靠性分析比较了限时无图像对比(模拟床旁间接检眼镜,sBIO)与不限时带图像对比(远程医疗,TELE)两种早产儿视网膜病变筛查阅片技术对变化检测的效用,发现两种技术准确率无差异(51.7% vs 51.9%,P=0.95),且阅片者对变化分级与图像及特征层面变化的一致性低。

要点

  • TELE与sBIO检测变化(Tempo)的准确率无差异(51.7% vs 51.9%,P=0.95)。
  • 所有检查均无变化时一致性最高(91.5% sBIO vs 93.5% TELE,P=0.46)。
  • Tempo评估与图像及特征层面变化的一致性低至31.4%和4.6%。

核心结论

  • 专家级小儿视网膜阅片者检测早产儿视网膜病变变化(Tempo)独立于筛查技术。
  • 两组阅片者在研究前6周表现显著更好,提示疲劳因素。
  • 这是早产儿视网膜病变史上首个研究表明阅片者以多种方式整合图像和视网膜特征,可能与其对整体疾病进展的评估相矛盾。

研究设计与样本

  • 前瞻性可靠性分析。
  • 金标准参考为已发表的精选早产儿视网膜病变图像数据库,包含40例患者的Tempo和特征层面变化,分2套。
  • 阅片者分为2个队列,两种筛查技术:sBIO(每人限时10分钟,可查看先前笔记和绘图)和TELE(不限时,可查看前几周图像、笔记和示意图)。
  • 阅片者在6周后交换技术和图像集。

主要发现

  • H1:sBIO与TELE相比金标准的准确率分别为51.7%和51.9%(P=0.95)。
  • 所有检查无变化时一致性最高(91.5% sBIO vs 93.5% TELE,P=0.46),所有检查均恶化时一致性最差(46.5% sBIO vs 47.1% TELE,P=0.93)。
  • 两组阅片者在第7-12周表现更差,与技术无关。
  • H2:Tempo评估与金标准图像层面变化总体一致性为31.4%(sBIO 31.2%,TELE 31.5%),与特征层面变化总体一致性为4.6%(sBIO 4.9%,TELE 4.3%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study compared two imaging grading techniques to assess the utility of longitudinal image-based analysis in retinopathy of prematurity (ROP) screening: (1) time-limited without image comparison (a proxy for bedside indirect ophthalmoscopy, termed sBIO) and time-unlimited with image comparison (for telemedicine grading, termed TELE) screening. We tested two hypotheses: (1) H1: TELE was superior to sBIO for the detection of change (Tempo)-same, better, or worse and (2) H2: granular data of change (e.g., at the image and feature level) is integrated by graders to achieve the Tempo assessment. DESIGN: Prospective reliability analysis. METHODS: Gold standard reference (GS) was a published curated ROP image database consisting of both Tempo and granular level changes (image and components) from 40 patients in 2 sets. Graders were divided into 2 cohorts. There were two screening techniques: (1) sBIO with time limited review of 10 minutes/patient, access to prior notes and drawings and (2) TELE with unlimited review time, access to prior weeks' images, notes and schematics. Graders switched techniques and sets after 6 weeks. H1 outcome was comparison of graders' weekly Tempo scores to GS-Gestalt and for H2 was Tempo score compared to GS-View and GS-Component. RESULTS: H1 demonstrated no difference-accuracy of sBIO and TELE compared to GS was 51.7% and 51.9% respectively (P = .95). Highest agreement occurred when all exams exhibited no change (91.5% sBIO vs 93.5% TELE, P = .46) and worst agreement was when exams always demonstrated worsening (46.5% sBIO vs 47.1% TELE, P = .93). Both sets of graders did worse in weeks 7-12, irrespective of technique. H2 demonstrated that Tempo assessment did not correlate with granular data changes in the GS for View level and Component level assessments-overall agreement dropped to 31.4% for Tempo vs GS-VIEW (31.2% for sBIO, 31.5% for TELE) and 4.6% for Tempo vs GS-COMPONENT (4.9% for sBIO, 4.3% for TELE). CONCLUSIONS: Detection of ROP Tempo was independent of screening technique by expert pediatric retina graders. Both groups did significantly better in the first half of the study, indicative of a fatigue factor. This is the first study in ROP history to demonstrate that graders integrate image and retinal features in various ways that can be in contradiction of their assessment of overall disease progression.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Rosenblatt TR, Ghoraba HH, Ji MH, et al. Longitudinal Assessment of Retinopathy of Prematurity (LONGROP) Study: Impacts of Viewing Time and Ability to Compare on Detection of Change. Am J Ophthalmol. 2024. PMID: 39461403. doi:10.1016/j.ajo.2024.10.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。