新型虚拟现实模拟交替遮盖试验评估斜视的前瞻性设盲研究

Evaluation of a Novel Virtual Reality Simulated Alternate Cover Test to Assess Strabismus: A Prospective, Masked Study.
PubMed 文献 · Am J Ophthalmol · 2024-09-06

这项前瞻性设盲诊断试验纳入85例5-18岁、视力20/80或更好的患者,比较虚拟现实(VR)模拟交替遮盖试验与金标准感觉运动检查测量斜视的一致性。VR与金标准总体相关性中等但显著(r=0.42),内斜视和恒定性偏斜者相关性强(r=0.74),但检测斜视的敏感性低(27.6%)、特异性高(87.5%);作者认为该技术有潜力但临床部署前仍需改进。

要点

  • VR模拟交替遮盖试验与金标准总体相关性中等但显著(r=0.42,95%CI 0.22,0.58,P<.001)。
  • 内斜视和恒定性偏斜者相关性强(r=0.74),水平斜视Bland-Altman分析显示内斜视平均差异3.55±8.33PD、外斜视17.15±11.20PD。
  • 检测斜视敏感性低(27.6%,95%CI 12.7,47.2)、特异性高(87.5%,95%CI 75.9,94.8)。

核心结论

  • 原型VR模拟交替遮盖试验与金标准感觉运动检查相关性中等但显著,内斜视和恒定性偏斜者相关性强。
  • 该VR技术显示的一致性水平有前景,但临床部署前仍需进一步改进。
  • 本研究显示VR有潜力扩展检测、测量和监测斜视的能力。

研究设计与样本

  • 前瞻性、设盲诊断试验,纳入5-18岁、视力20/80或更好的患者85例。
  • 患者先接受VR模拟交替遮盖试验(Olleyes, Inc., Summit, NJ),随后由设盲的儿童眼科医生或视能矫正师行交替遮盖试验。
  • 主要结局为金标准与VR获得的斜视测量值(棱镜度[PD],近距原在位)之间的相关性,采用Pearson相关系数和Bland-Altman分析及一致性界限(LOA)。
  • 次要结局为VR头戴设备检测斜视的诊断准确性。

主要发现

  • 共纳入85例,平均年龄10.8±3.8岁,男性45.9%(39/85)。
  • 40.0%(34/85)患有斜视:内斜视17.7%(15/85)、外斜视22.4%(19/85)、垂直斜视5.9%(5/85);52.9%(18/34)的斜视为间歇性。
  • VR与金标准总体相关性中等但显著(r=0.42,95%CI 0.22,0.58,P<.001),内斜视(r=0.74,95%CI 0.38,0.91,P=.001)和恒定性偏斜(r=0.74,95%CI 0.39,0.91,P<.001)相关性均强。
  • 水平斜视者Bland-Altman分析:内斜视标准与VR测量平均差异3.55±8.33PD(LOA上限19.89PD、下限-12.78PD),外斜视平均差异17.15±11.20PD(LOA上限39.09PD、下限-4.79PD)。
  • 检测斜视敏感性低:27.6%(95%CI 12.7,47.2),特异性高:87.5%(95%CI 75.9,94.8)。

临床怎么用

  • 作者认为该VR技术显示的一致性水平有前景,但临床部署前仍需进一步改进。
  • 作者认为VR有潜力扩展检测、测量和监测斜视的能力。

局限性

  • 作者指出该VR技术临床部署前仍需进一步改进。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: A sensorimotor examination is the gold standard for strabismus diagnosis and quantification but requires a highly skilled examiner and may be limited by a child's cooperation. Virtual reality (VR) employs eye-tracking technology to monitor eye position and may be able to measure strabismus. The aim of this study was to assess a prototype VR-simulated alternate cover test to detect and measure strabismus. DESIGN: Prospective, masked diagnostic test study. METHODS: Patients aged 5-18 years with visual acuity of 20/80 or better were prospectively enrolled to undergo strabismus measurements using a VR simulated alternate cover test (Olleyes, Inc., Summit, NJ) followed by an alternate cover test performed by a masked pediatric ophthalmologist or orthoptist. The main outcome measure was correlation between gold standard and VR-obtained strabismus measurements (in prism diopters [PD]) in primary gaze at near using Pearson correlation coefficients and Bland-Altman analysis with limits of agreement (LOA). A secondary measure was the diagnostic accuracy for the VR headset to detect strabismus. RESULTS: A total of 85 participants were enrolled, mean ± standard deviation age was 10.8 ± 3.8 years, 45.9% (39/85) male. 40.0% (34/85) had strabismus: 17.7% (15/85) esotropia, 22.4% (19/85) exotropia, and 5.9% (5/85) vertical strabismus. 52.9% (18/34) of strabismus was intermittent. The overall correlation between VR and gold standard strabismus measurements was moderate but significant (r = 0.42, 95% CI 0.22, 0.58, P < .001), and correlation was strong for esotropia and constant deviations (r = 0.74, 95% CI 0.38, 0.91, P = .001 and r = 0.74, 95% CI 0.39, 0.91, P < .001, respectively). In participants with horizontal strabismus, Bland-Altman analysis showed a mean difference between standard and VR measurements of 3.55 ± 8.33 PD for esotropia (upper and lower LOA 19.89, -12.78 PD) and 17.15 ± 11.20 PD for exotropia (LOA 39.09 and -4.79 PD). Sensitivity for detecting strabismus was low: 27.6% (95% CI 12.7, 47.2), but specificity was high: 87.5% (95% CI 75.9, 94.8). CONCLUSIONS: A prototype VR simulated alternate cover test showed a moderate but significant correlation with the gold standard sensorimotor examination and correlation was strong in those with esotropia and constant deviations. While the level of agreement demonstrated by this novel VR technology is promising, further improvements are needed before clinical deployment. However, this study demonstrates that VR has the potential to expand our ability to detect, measure, and monitor strabismus.