使用红细胞介导血管造影与光密度相干断层扫描血管成像的丛特异性视网膜毛细血管血流分析
本研究在2只非人灵长类动物和11名人类受试者中,采用红细胞介导血管造影(EMA)与光密度相干断层扫描血管成像(OCTA)测量视网膜毛细血管血流速度与加速度,并按浅层血管丛(SVP)、中间毛细血管丛(ICP)和深层毛细血管丛(DCP)分类。基线眼压下毛细血管红细胞速度在非人灵长类为0.64±0.29 mm/s、人类为1.55±0.65 mm/s;人类三个血管丛间无显著差异(P=0.36)。在非人灵长类中,眼压每升高1 mm Hg,动脉速度降低0.13 mm/s、静脉速度降低0.10 mm/s、毛细血管速度降低0.01 mm/s(P<0.001)。
要点
- 在非人灵长类与人类中,EMA与OCTA可量化视网膜毛细血管丛内单个红细胞的血流速度。
- 人类SVP、ICP、DCP红细胞速度无显著差异(1.46±0.59、1.58±0.55、1.59±0.79 mm/s,P=0.36)。
- 非人灵长类实验性眼压升高时,动脉、静脉和毛细血管红细胞速度均随眼压升高而降低(P<0.001)。
核心结论
- 通过直接可视化单个红细胞,可量化毛细血管丛内的血流。
- 实验性眼压升高时毛细血管速度降低。
研究设计与样本
- 研究纳入2只非人灵长类动物和11名人类受试者,获取以黄斑中心凹为中心的EMA和OCTA扫描。
- 还在非人灵长类眼实验性升高眼压时获取扫描。
- 测量视网膜动脉、毛细血管和静脉的红细胞速度与加速度,并按SVP、ICP、DCP对毛细血管分类。
- 使用广义线性混合模型估计眼压对毛细血管血流的影响。
主要发现
- 基线眼压下毛细血管红细胞速度在非人灵长类为0.64±0.29 mm/s(范围0.14至1.85 mm/s),在人类为1.55±0.65 mm/s(范围0.46至4.50 mm/s)。
- 非人灵长类SVP、ICP、DCP平均红细胞速度分别为0.69±0.29 mm/s、0.53±0.22 mm/s、0.63±0.27 mm/s(NHP-1 P=0.14,NHP-2 P=0.28)。
- 人类SVP、ICP、DCP平均红细胞速度分别为1.46±0.59 mm/s、1.58±0.55 mm/s、1.59±0.79 mm/s,无显著差异(P=0.36)。
- 在非人灵长类中,校正平均动脉压(MAP)差异后,眼压每升高1 mm Hg,动脉速度降低0.13 mm/s、静脉速度降低0.10 mm/s、毛细血管速度降低0.01 mm/s(P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study was to identify and measure plexus-specific absolute retinal capillary blood flow velocity and acceleration in vivo in both nonhuman primates (NHPs) and humans using erythrocyte mediated angiography (EMA) and optical coherence tomography angiography (OCTA). METHODS: EMA and OCTA scans centered on the fovea were obtained in 2 NHPs and 11 human subjects. Scans were also obtained in NHP eyes while IOP was experimentally elevated. Erythrocyte velocity and acceleration in retinal arteries, capillaries, and veins were measured and capillaries were categorized based on location within the superficial vascular (SVP), intermediate capillary (ICP), or deep capillary plexus (DCP). Generalized linear mixed models were used to estimate the effects of intraocular pressure (IOP) on capillary blood flow. RESULTS: Capillary erythrocyte velocity at baseline IOP was 0.64 ± 0.29 mm/s in NHPs (range of 0.14 to 1.85 mm/s) and 1.55 ± 0.65 mm/s in humans (range of 0.46 to 4.50 mm/s). Mean erythrocyte velocity in the SVP, ICP, and DCP in NHPs was 0.69 ± 0.29 mm/s, 0.53 ± 0.22 mm/s, and 0.63 ± 0.27 mm/s, respectively (P = 0.14 for NHP-1 and P = 0.28 for NHP-2). Mean erythrocyte velocity in the human subjects did not differ significantly among SVP, ICP, and DCP (1.46 ± 0.59 mm/s, 1.58 ± 0.55 mm/s, and 1.59 ± 0.79 mm/s, P = 0.36). In NHPs, every 1 mm Hg increase in IOP was associated with a 0.13 mm/s reduction in arterial velocity, 0.10 mm/s reduction in venous velocity, and 0.01 mm/s reduction in capillary velocity (P < 0.001) when accounting for differences in mean arterial pressure (MAP). CONCLUSIONS: Blood flow by direct visualization of individual erythrocytes can be quantified within capillary plexuses. Capillary velocity decreased with experimental IOP elevation.
引用
- Chen VY, Pottenburgh JA, Chen SE, et al. Plexus-Specific Retinal Capillary Blood Flow Analysis Using Erythrocyte Mediated Angiography and Optical Coherence Tomography Angiography. Invest Ophthalmol Vis Sci. 2024. PMID: 39302644. doi:10.1167/iovs.65.11.33
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。