使用多层感知机驱动的诊断比较原发性开角型青光眼的生物标志物
本研究使用神经网络机器学习模型,在93例青光眼患者和113例对照者的前瞻性观察数据中,比较不同眼部生物标志物对原发性开角型青光眼诊断的价值。结果显示血管和结构模型均显著优于基础模型,血管模型AUC为0.819,结构模型AUC为0.816,两者差异不显著。
要点
- 血管和结构模型诊断准确性均显著高于仅用基础参数的基础模型。
- 血管模型AUC 0.819与结构模型AUC 0.816相比,差异不显著。
- GCC+RNFL模型及含全部结构和血管特征的模型也显著优于基础模型。
核心结论
- 神经网络模型表明,与OCT结构生物标志物特征相比,OCTA视神经乳头血管生物标志物对原发性开角型青光眼的机器学习诊断同样有用。
研究设计与样本
- 研究为前瞻性收集的观察性数据集,包含93例经青光眼专家确诊的青光眼患者和113例对照者。
- 使用神经网络模型(即多层感知机)进行训练,评估了三种不同结构的MLP,并采用十折交叉验证。
主要发现
- 血管模型和结构模型的测试AUC均显著高于基础模型,血管模型AUC为0.819,结构模型AUC为0.816,血管模型优于结构模型但差异不显著。
- GCC+RNFL模型以及包含全部结构和血管特征的模型也显著比基础模型更准确。
关键数值与推荐
- 基础模型仅使用眼压、血压、心率和视野参数诊断青光眼。
- 结构特征模型在基础参数上增加OCT测量的视神经参数、视网膜神经纤维层、神经节细胞复合体和黄斑厚度。
- 血管特征模型在基础参数上增加OCTA测量的血管特征。
- GCC+RNFL模型在基础参数上仅增加OCT测量的RNFL和GCC厚度。
- 模型测试AUC比较采用独立样本t检验。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To use neural network machine learning (ML) models to identify the most relevant ocular biomarkers for the diagnosis of primary open-angle glaucoma (POAG). METHODS: Neural network models, also known as multi-layer perceptrons (MLPs), were trained on a prospectively collected observational dataset comprised of 93 glaucoma patients confirmed by a glaucoma specialist and 113 control subjects. The base model used only intraocular pressure, blood pressure, heart rate, and visual field (VF) parameters to diagnose glaucoma. The following models were given the base parameters in addition to one of the following biomarkers: structural features (optic nerve parameters, retinal nerve fiber layer [RNFL], ganglion cell complex [GCC] and macular thickness), choroidal thickness, and RNFL and GCC thickness only, by optical coherence tomography (OCT); and vascular features by OCT angiography (OCTA). RESULTS: MLPs of three different structures were evaluated with tenfold cross validation. The testing area under the receiver operating characteristic curve (AUC) of the models were compared with independent samples t-tests. The vascular and structural models both had significantly higher accuracies than the base model, with the hemodynamic AUC (0.819) insignificantly outperforming the structural set AUC (0.816). The GCC + RNFL model and the model containing all structural and vascular features were also significantly more accurate than the base model. CONCLUSIONS: Neural network models indicate that OCTA optic nerve head vascular biomarkers are equally useful for ML diagnosis of POAG when compared to OCT structural biomarker features alone.
引用
- Riina N, Harris A, Siesky BA, et al. Using Multi-Layer Perceptron Driven Diagnosis to Compare Biomarkers for Primary Open Angle Glaucoma. Invest Ophthalmol Vis Sci. 2024. PMID: 39250119. doi:10.1167/iovs.65.11.16
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。