眼压与青光眼的关系:一个不断演变的概念
本文综述眼压与青光眼关系的演变,涵盖眼压决定因素、测量技术、多维度眼压指标的科学与临床依据、现有眼压监测方法的局限及改进建议。回顾性和前瞻性数据显示青光眼眼压波动大于健康眼,最高眼压常出现在诊室外时段,且眼压波动与青光眼进展相关且独立于平均诊室眼压。动态眼压监测可提供离散数据以改善患者结局,但需前瞻性随机对照研究验证。
要点
- 青光眼眼压波动大于健康眼,最高日间眼压常出现在诊室外时段。
- 眼压波动与青光眼进展相关,且独立于平均诊室眼压。
- 仅依据诊室孤立眼压测量可能无法完整反映个体眼压全貌。
核心结论
- 眼压是青光眼最重要的可干预危险因素,在患者短期和长期内波动显著。
- 动态眼压监测测量诊室外及昼夜不同时段的眼压,可提供离散数据以改善患者结局。
- 需前瞻性随机对照研究确定基于远程眼压监测的青光眼管理能否减少视力丧失并改善患者结局。
研究设计与样本
- 综述回顾已发表文献,涵盖回顾性和前瞻性数据,包括里程碑临床试验数据。
主要发现
- 青光眼眼压波动大于健康眼。
- 最高日间眼压倾向于出现在诊室外时段。
- 除平均眼压和最高眼压外,眼压波动与青光眼进展相关且独立于平均诊室眼压。
临床怎么用
- 动态眼压监测测量诊室外及昼夜不同时段的眼压,为临床医生提供离散数据,可能改善患者结局。
- 仅依据诊室孤立眼压测量治疗青光眼,可能在不完全了解个体眼压全貌的情况下做出治疗决策。
局限性
- 需前瞻性随机对照研究确定基于远程眼压监测的青光眼管理能否减少视力丧失并改善患者结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Intraocular pressure (IOP) is the most important modifiable risk factor for glaucoma and fluctuates considerably within patients over short and long time periods. Our field's understanding of IOP has evolved considerably in recent years, driven by tonometric technologies with increasing accuracy, reproducibility, and temporal resolution that have refined our knowledge regarding the relationship between IOP and glaucoma risk and pathogenesis. The goal of this article is to review the published literature pertinent to the following points: 1) the factors that determine IOP in physiologic and pathologic states; 2) technologies for measuring IOP; 3) scientific and clinical rationale for measuring diverse IOP metrics in patients with glaucoma; 4) the impact and shortcomings of current standard-of-care IOP monitoring approaches; 5) recommendations for approaches to IOP monitoring that could improve patient outcomes; and 6) research questions that must be answered to improve our understanding of how IOP contributes to disease progression. Retrospective and prospective data, including that from landmark clinical trials, document greater IOP fluctuations in glaucomatous than healthy eyes, tendencies for maximal daily IOP to occur outside of office hours, and, in addition to mean and maximal IOP, an association between IOP fluctuation and glaucoma progression that is independent of mean in-office IOP. Ambulatory IOP monitoring, measuring IOP outside of office hours and at different times of day and night, provides clinicians with discrete data that could improve patient outcomes. Eye care clinicians treating glaucoma based on isolated in-office IOP measurements may make treatment decisions without fully capturing the entire IOP profile of an individual. Data linking home blood pressure monitors and home glucose sensors to dramatically improved outcomes for patients with systemic hypertension and diabetes and will be reviewed as they pertain to the question of whether ambulatory tonometry is positioned to do the same for glaucoma management. Prospective randomized controlled studies are warranted to determine whether remote tonometry-based glaucoma management might reduce vision loss and improve patient outcomes.
引用
- Asrani SG, McGlumphy EJ, Al-Aswad LA, et al. The relationship between intraocular pressure and glaucoma: An evolving concept. Prog Retin Eye Res. 2024. PMID: 39303763. doi:10.1016/j.preteyeres.2024.101303
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。