优化葡萄膜黑色素瘤眼内切除术的手术操作与安全性
本文介绍一种标准化的葡萄膜黑色素瘤眼内切除术,旨在降低包括致命性气体栓塞在内的严重不良事件风险。10例葡萄膜黑色素瘤患者在接受质子束放疗后因放疗相关血管并发症行眼内切除术,术中避免使用空气,所有患眼手术成功且无术中并发症,平均随访10.8个月±3.2个月,1例因新生血管性青光眼行眼球摘除。
要点
- 肿瘤基底对应位置的涡静脉在放置钽标记物时已行电凝。
- 行完全25-G玻璃体切除、眼内激光和眼内电凝后,根据视网膜浸润情况选择视网膜下或经视网膜途径切除肿瘤。
- 如需稳定视网膜可注入全氟萘烷,行液体-硅油或全氟萘烷-硅油交换,避免使用空气。
核心结论
- 作者认为其标准化的葡萄膜黑色素瘤眼内切除术式似乎是安全的,可将严重术中及术后不良事件的风险降至最低。
研究设计与样本
- 本文报告10例葡萄膜黑色素瘤患者在接受质子束放疗后因放疗相关血管并发症行眼内切除术。
主要发现
- 所有患眼均成功完成眼内切除术,无术中并发症。
- 平均随访10.8个月±3.2个月,1例患者因新生血管性青光眼行眼球摘除。
- 末次随访时,其余患者眼球保留,无局部复发或新生血管性青光眼征象。
关键数值与推荐
- 肿瘤基底对应位置的涡静脉在放置钽标记物时已行电凝。
- 眼内切除术在完全25-G玻璃体切除、眼内激光和眼内电凝后进行。
- 根据视网膜浸润情况采用视网膜下或经视网膜途径切除肿瘤。
- 如需稳定视网膜可注入全氟萘烷;行液体-硅油或全氟萘烷-硅油交换,避免使用空气。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To present a standardized surgical technique for endoresection of uveal melanoma minimizing the risk of serious adverse events, including fatal gas embolism. METHODS: Ten uveal melanoma patients underwent endoresection following proton beam radiotherapy for radiotherapy-related vascular complications. Vortex veins located in correspondence of the tumor base had been cauterized at the time of tantalum markers placement. Endoresection was performed following complete 25-G vitrectomy, endolaser, and endodiathermy. The tumor was removed using a subretinal or transretinal approach depending on retinal infiltration. If needed, perfluorodecalin was injected to stabilize the retina. Fluid-silicone oil or perfluorodecalin-silicone oil exchange was performed, avoiding air. RESULTS: Endoresection was successfully performed in all eyes with no intraoperative complications. Mean follow-up was 10.8 months ± 3.2 months. One patient was enucleated due to neovascular glaucoma. At the last follow-up, the remaining patients had the eye preserved and no signs of local recurrence or neovascular glaucoma. CONCLUSION: Our standardized surgical technique for uveal melanoma endoresection appeared to be safe, minimizing the risk of serious intraoperative and postoperative adverse events.
引用
- Romano MR, Ferrara M, Feo A, et al. Optimizing Surgical Performance and Safety in Endoresection of Uveal Melanoma. Retina. 2025. PMID: 39325701. doi:10.1097/IAE.0000000000004273
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。