人睑脂在生理盐水上铺展的高分辨率图像
本研究用高分辨率彩色显微镜观察10名受试者睑脂在缓冲生理盐水上铺展随温度的变化,初始形成7.8±0.3 nm厚的背景层和不规则岛状结构,去润湿形成透镜状液滴。低于30°C时透镜状液滴发出含多达约49层、每层4.82±0.13 nm的多层结构,与X射线研究的4.88 nm层状结构一致;高于30°C时未观察到X射线研究中的11.1 nm层状结构。
要点
- 睑脂铺展于生理盐水后去润湿形成透镜状液滴,低于30°C时发出多层尾状结构。
- 低于30°C时尾状结构含多达约49层,每层厚4.82±0.13 nm,与X射线4.88 nm层状结构一致。
- 高于30°C时未观察到X射线研究中的11.1 nm层状结构,提示其可能被无序脂质分隔。
核心结论
- 低于30°C时睑脂在生理盐水上铺展显示与X射线研究4.88 nm厚度相似的多层结构,证明可观察和测量紧密堆叠的层状结构。
- 高于30°C时未观察到X射线研究中的11.1 nm层状结构,提示这些层状结构未被紧密堆叠而可能被无序脂质分隔。
- 文中讨论了这些发现在蒸发过强型干眼中的作用。
研究设计与样本
- 用特制高分辨率彩色显微镜研究10名受试者的睑脂,将其铺展在近40°C的缓冲生理盐水上并冷却至室温。
- 应用既往研究中的分析方法测量睑脂和层状结构厚度。
主要发现
- 初始形成不规则「岛」状结构,周围为厚度7.8±0.3 nm的背景层。
- 睑脂层总是发生去润湿,导致形成透镜状液滴。
- 低于30°C时透镜状液滴开始发出「尾」状结构,具有多层结构,在背景层上叠加多达约49层,每层厚4.82±0.13 nm。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Understanding of the role of the tear film lipid layer (TFLL) in evaporative dry eye requires knowledge of its structure. X-ray studies show 11.1-nm thick lamellae in meibum at tear film temperature (approximately 35°C), whereas below 30°C, 4.88-nm thick lamellae predominate. Here, high resolution microscopy of meibum spread on saline is studied as a function of temperature, to compare with x-ray results. METHODS: A purpose-built high resolution color microscope, previously used to study the TFLL, was used to study meibum from 10 subjects. It was spread on buffered saline at near 40°C, and allowed to cool to room temperature. Analytical methods from previous studies were applied to measure meibum and lamellar thickness. RESULTS: Initially, an irregular "island" was formed, surrounded by a "background layer" of 7.8 ± 0.3 nm thickness. Dewetting of the meibum layer always occurred, leading to the formation of lens-shaped droplets. Below 30°C, the lenses start to emit "tails" having a multilamellar structure containing up to about 49 lamellae superimposed on the background layer, each lamella being 4.82 ± 0.13 nm thick. CONCLUSIONS: Below 30°C, meibum spread on saline shows a multilamellar structure like the 4.88 nm thickness in x-ray studies, demonstrating the ability to observe and measure tightly stacked lamellae. In contrast, above 30°C, the 11.1 nm lamellae were not observed as in x-ray studies, indicating that these lamellae were not tightly stacked but may be separated by disordered lipid. The role of these findings in evaporative dry eye is discussed.
引用
- King-Smith PE, Begley CG, Braun RJ, et al. High Resolution Images of Human Meibum Spread on Saline. Invest Ophthalmol Vis Sci. 2024. PMID: 39046756. doi:10.1167/iovs.65.8.41
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。