宽场光学相干断层扫描成像较标准场成像提高进展性青光眼眼别变化检出率
研究纳入25名健康人45眼和161例青光眼患者263眼,比较单宽场(SWF)与视神经乳头(ONH)立方扫描OCT测量视网膜神经纤维层变化速率。青光眼眼中SWF全局变化速率为-1.22 µm/年(P<0.001),ONH为-0.83 µm/年(P=0.003);进展性青光眼眼别SWF变化速率显著大于非进展性(-1.51 vs -1.24 µm/年,P=0.002),ONH扫描无显著差异(P=0.27)。
要点
- 青光眼眼中SWF图像测得RNFL全局变化速率为-1.22 µm/年,ONH立方扫描为-0.83 µm/年。
- 进展性青光眼眼别SWF变化速率-1.51 µm/年,显著大于非进展性眼别-1.24 µm/年(P=0.002)。
- ONH立方扫描在进展性与非进展性青光眼间变化速率无显著差异(P=0.27)。
核心结论
- 在包含高轴性近视眼和无高轴性近视眼的队列中,SWF图像测得的RNFL平均变薄速率在进展性青光眼眼中快于非进展性青光眼眼。
- 包含ONH和黄斑的宽场OCT图像可能有效用于监测伴或不伴高度近视的青光眼患者的进展。
研究设计与样本
- 研究纳入来自青光眼诊断创新研究(Diagnostic Innovations in Glaucoma Study)的25名健康人45眼和161例青光眼患者263眼。
- 所有眼均接受24-2视野检查和Spectralis SD-OCT的ONH及黄斑成像。
- SWF图像(最大43°×28°)由以视盘为中心的ONH立方扫描和以黄斑中心凹为中心的黄斑立方扫描拼接而成。
- 视野进展定义为引导进展分析可能进展和/或平均偏差斜率显著(P<0.01)且小于-1.0 dB/年。
- 采用混合效应模型比较变化速率,纳入高度近视眼。
主要发现
- 30只青光眼眼被分类为进展性。
- 青光眼眼中,SWF图像测得的全局平均变化速率为-1.22 µm/年(P<0.001),ONH立方扫描为-0.83 µm/年(P=0.003)。
- 进展性青光眼眼SWF图像变化速率为-1.51 µm/年,非进展性青光眼眼为-1.24 µm/年,差异显著(P=0.002)。
- ONH立方扫描测得的进展性与非进展性青光眼眼变化速率无显著差异(P=0.27)。
临床怎么用
- 作者认为,包含ONH和黄斑的宽场OCT图像可能有效用于监测伴或不伴高度近视的青光眼患者的进展。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare rates of retinal nerve fiber layer change over time in healthy, eyes with nonprogressing glaucoma and eyes with progressing glaucoma using single wide-field (SWF) and optic nerve head (ONH) cube scan optical coherence tomography (OCT) images. METHODS: Forty-five eyes of 25 healthy individuals and 263 eyes of 161 glaucoma patients from the Diagnostic Innovations in Glaucoma Study were included. All eyes underwent 24-2 visual field testing and OCT (Spectralis SD-OCT) ONH and macular imaging. SWF images (up to 43° × 28°) were created by stitching together ONH cube scans centered on the optic disc and macular cube scans centered on the fovea. Visual field progression was defined as guided progression analysis likely progression and/or a significant (P < 0.01) mean deviation slope of less than -1.0 dB/year. Mixed effects models were used to compare rates of change. Highly myopic eyes were included. RESULTS: Thirty glaucomatous eyes were classified as progressing. In eyes with glaucoma, mean global rate of change was -1.22 µm/year (P < 0.001) using SWF images and -0.83 µm/year (P = 0.003) using ONH cube scans. Rate of change was significantly greater in eyes with progressing glaucoma compared with eyes with nonprogressing glaucoma (-1.51 µm/year vs. -1.24 µm/year; P = 0.002) using SWF images and was similar using ONH cube scans (P = 0.27). CONCLUSIONS: In this cohort that includes eyes with and without high axial myopia, the mean rate of retinal nerve fiber layer thinning measured using SWF images was faster in eyes with progressing glaucoma than in eyes with nonprogressing glaucoma. Wide-field OCT images including the ONH and macula can be effective for monitoring glaucomatous progression in patients with and without high myopia.
引用
- Bowd C, Belghith A, Rezapour J, et al. Wide-Field Optical Coherence Tomography Imaging Improves Rate of Change Detection in Progressing Glaucomatous Eyes Compared With Standard-Field Imaging. Invest Ophthalmol Vis Sci. 2024. PMID: 38980269. doi:10.1167/iovs.65.8.18
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。