青光眼患者、青光眼疑似者与健康对照者系统性脉搏波形差异
研究比较青光眼(GL)、青光眼疑似(GLS)与健康对照(HC)的系统性血压脉搏波形,发现HC组平均血压(91.7±11.7 mm Hg)显著低于GLS组(102.4±13.9)和GL组(102.8±13.7),P<0.0001;反映血管阻力的波形参数在GLS和GL组均高于HC组,并与视网膜神经纤维层厚度和视野平均偏差相关(P≤0.05)。结论认为GL/GLS者的系统性脉搏波形形态与HC眼不同,GL者血压变化更快,提示动脉僵硬度更高。
要点
- HC组平均血压91.7±11.7 mm Hg,显著低于GLS组102.4±13.9和GL组102.8±13.7(P<0.0001)。
- 反映血管阻力的脉搏波形参数在GLS和GL组均高于HC组,且与RNFLT和MDlin相关(P≤0.05)。
- GL者血压变化更快,提示动脉僵硬度更高。
核心结论
- GL/GLS者的系统性脉搏波形形态与HC眼不同,GL者血压变化更快,提示动脉僵硬度更高。
研究设计与样本
- 研究纳入35例双侧GL、67例双侧GLS、29例单侧GL且对侧眼视为GLS者以及44例健康对照。
- 采用指套记录系统性搏动性血压波形,以200 Hz连续体积描记获得脉搏波形,用自定义软件从8个脉搏周期平均值中提取波形参数。
- 按眼别比较GL、GLS和HC组,使用广义估计方程模型校正眼间相关,并将波形参数与视野线性化平均偏差(MDlin)和视网膜神经纤维层厚度(RNFLT)对照分析。
主要发现
- HC组平均血压(均值±标准差91.7±11.7 mm Hg)显著低于GLS组(102.4±13.9)和GL组(102.8±13.7),P<0.0001(广义估计方程回归)。
- 反映血管阻力的波形参数在GLS和GL组均高于HC组,且与RNFLT和MDlin相关(P≤0.05)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: It has been hypothesized that compromised ocular circulation in glaucoma may be concomitant of systemic changes. The purpose of this study is to test whether systemic blood flow pulse waveform patterns differ between individuals with glaucoma (GL), glaucoma suspects (GLS), and normal healthy controls (HC). METHODS: The study included 35 bilateral GL, 67 bilateral GLS, 29 individuals with unilateral GL who were considered GLS in the other eye, and 44 healthy controls. Systemic pulsatile blood pressure waveforms were recorded using a finger cuff. A continuous 200 Hz plethysmography recording is made to obtain a pulse waveform. Waveform parameters were extracted using custom software from an average of eight pulse cycles. These were compared between GL, GLS, and HC groups on a per-eye basis, using generalized estimating equation models to account for intereye correlations; and plotted against disease severity by visual field linearized mean deviation (MDlin) and retinal nerve fiber layer thickness (RNFLT). RESULTS: Averaged blood pressure was significantly lower in the HC group (mean ± standard deviation 91.7 ±11.7 mm Hg) than the GLS (102.4 ± 13.9) or GL (102.8 ± 13.7) groups, with P < 0.0001 (generalized estimating equation regression). Waveform parameters representing vascular resistance were higher in both GLS and GL groups than the HC group; and were correlated with RNFLT and MDlin (P ≤ 0.05). CONCLUSIONS: The shape of the systemic pulsatile waveform differs in individuals with GL/GLS suspects, compared to HC eyes. Blood pressure changes more rapidly in individuals with GL, which suggests higher arterial stiffness.
引用
- Yang H, Cull G, Yang M, et al. Differences in Systemic Pulse Waveform Between Individuals With Glaucoma, Glaucoma Suspects, and Healthy Controls. Invest Ophthalmol Vis Sci. 2024. PMID: 38990070. doi:10.1167/iovs.65.8.20
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。