原发性开角型青光眼中微血管丢失处筛板微结构的基础研究
本研究纳入原发性开角型青光眼(POAG)眼,评估筛板微血管丢失(MvD-LC)或视盘周围脉络膜微血管丢失(MvD-PC)与深部视神经乳头筛板微结构的关系。结果显示MvD-LC与筛板局部变薄及预处理眼压升高相关,且部分MvD-LC眼不伴MvD-PC,其临床意义可能与MvD-PC不同。
要点
- MvD-LC与筛板局部厚度降低(OR=0.96)及平均厚度降低(OR=0.97)相关。
- MvD-LC与预处理眼压升高(OR=1.22)及视野模式标准差增大(OR=1.20)相关。
- 15%的MvD-LC眼(14/93)不伴MvD-PC,其临床意义可能与MvD-PC不同。
核心结论
- MvD-LC与筛板局部形态学改变相关,且MvD-LC眼倾向于有更高的预处理眼压。
- 在POAG眼中,MvD-LC的临床意义应与MvD-PC不同。
研究设计与样本
- 研究纳入POAG眼,分为有MvD-LC眼93只和无MvD-LC眼51只,采用光学相干断层扫描和光学相干断层扫描血管成像评估深部视神经乳头结构和微血管。
主要发现
- MvD-LC的存在与更低的局部筛板厚度(OR=0.96,P<0.001)和平均筛板厚度(OR=0.97,P=0.032)相关。
- MvD-LC的存在与更大的视野模式标准差(OR=1.20,P=0.038)和更高的预处理眼压(OR=1.22,P=0.012)相关。
- 15%的MvD-LC眼(14/93)不伴MvD-PC,这些眼较同时有MvD-LC和MvD-PC的眼年龄更小(P=0.043)、视盘旁脉络膜更厚(P=0.018)、局部筛板曲率指数更大(P=0.040)、视网膜神经纤维层更厚(P=0.024)、视野模式标准差更小(P=0.008)、预处理眼压更高(P=0.006)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine the microstructure of the lamina cribrosa (LC) associated with microvasculature dropout (MvD) of the deep optic nerve head (ONH) in primary open-angle glaucoma (POAG) and to identify factors related to the presence of MvD. METHODS: POAG eyes that exhibited MvD in the LC (MvD-LC) or MvD in the peripapillary choroid (MvD-PC) underwent optical coherence tomography and optical coherence tomography angiography (OCTA) to evaluate the structure and microvasculature of the deep ONH, respectively. The presence of MvD-LC or MvD-PC was determined using en face OCTA images of the deep ONH. The sectoral LC thickness (LCT) and LC curvature index (LCCI) (at MvD-LC site, when applicable), the mean LCT and LCCI of the global ONH, and other clinical characteristics were measured and compared between eyes with and without MvD-LC. RESULTS: The study included 93 eyes with and 51 without MvD-LC. The presence of MvD-LC was associated with lower sectoral LCT (odds ratio [OR] = 0.96, P < 0.001) and mean LCT (OR = 0.97, P = 0.032), larger visual field pattern standard deviation (PSD; OR = 1.20, P = 0.038), and higher pretreatment intraocular pressure (IOP; OR = 1.22, P = 0.012). Fifteen percent of the eyes with MvD-LC (14/93) did not present MvD-PC. Those eyes had younger age (P = 0.043), thicker juxtapapillary choroid (P = 0.018), larger sectoral LCCI (P = 0.040), thicker retinal nerve fiber layer (P = 0.024), smaller PSD (P = 0.008), and higher pretreatment IOP (P = 0.006) than those with both MvD-LC and MvD-PC. CONCLUSIONS: MvD-LC was associated with a localized morphologic alteration of the LC, and eyes with MvD-LC tended to have a higher pretreatment IOP. The clinical implications of MvD-LC should differ from those of MvD-PC in eyes with POAG.
引用
- Lee EJ, Han DK, Roh YJ, et al. Underlying Microstructure of the Lamina Cribrosa at the Site of Microvasculature Dropout. Invest Ophthalmol Vis Sci. 2024. PMID: 39078730. doi:10.1167/iovs.65.8.47
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。