文献速递白内障与屈光手术眼底病与葡萄膜炎小儿眼科与斜弱视

晶状体半脱位眼行Cionni环及囊袋内人工晶状体植入术后的长期预后

Long-Term Postoperative Outcomes Following Cionni Ring and In-the-Bag Intraocular Lens Implantation in Eyes With Subluxated Lenses.
PubMed 文献 · Am J Ophthalmol · 2024-07-14

印度Raghudeep眼科医院回顾性病例系列纳入41眼(31例)晶状体半脱位眼,行晶状体摘除、9-0聚丙烯缝线固定Cionni改良囊袋张力环及囊袋内人工晶状体植入,平均随访9.89±3.81年。末次随访32眼(74%)最佳矫正远视力≥0.3 logMAR,7眼(17%)人工晶状体偏位需二次手术,4眼(10%)视网膜脱离。作者认为长期视力预后良好、严重并发症率可接受,但17%偏位率提示需比较非可降解缝线材料及巩膜固定方式的偏位率。

要点

  • 41眼晶状体半脱位眼中,74%末次随访最佳矫正远视力≥0.3 logMAR。
  • 人工晶状体偏位7眼(17%),距初次手术平均8.79年需二次手术。
  • 视网膜脱离4眼(10%),其中3眼为Marfan综合征。

核心结论

  • 9-0聚丙烯缝线固定Cionni改良囊袋张力环联合囊袋内人工晶状体植入在晶状体半脱位眼中长期视力预后良好,严重术后并发症率可接受。
  • 该方法可保留眼自然腔隙并将人工晶状体置于最生理位置。
  • 考虑到17%人工晶状体偏位需手术干预,作者提出应比较聚四氟乙烯等非可降解缝线材料的长期稳定性以及缝线或无缝线巩膜固定后的偏位率。

研究设计与样本

  • 回顾性病例系列,纳入印度Raghudeep眼科医院41眼(31例)晶状体半脱位眼,均完成至少5年术后随访。
  • 所有眼行晶状体摘除、9-0聚丙烯缝线固定Cionni改良囊袋张力环及囊袋内人工晶状体植入。
  • 末次随访记录最佳矫正远视力、人工晶状体居中性、后囊膜混浊、青光眼及视网膜并发症。

主要发现

  • 队列平均年龄20.48±16.46岁,24眼(58%)手术时年龄小于15岁,Marfan综合征占37%。
  • 平均随访9.89±3.81年,末次随访32眼(74%)最佳矫正远视力≥0.3 logMAR。
  • 人工晶状体偏位7眼(17%)需二次手术,从初次手术到再手术平均8.79年。
  • 17眼(41%)需激光后囊膜切开,其中88%为儿童眼。
  • 视网膜脱离4眼(10%),其中3眼为Marfan综合征。

关键数值与推荐

  • 人工晶状体偏位需二次手术的比例为17%(7/41眼),从初次手术到再手术平均8.79年。
  • 末次随访最佳矫正远视力≥0.3 logMAR的比例为74%(32/41眼)。
  • 激光后囊膜切开比例为41%(17/41眼),其中88%为儿童眼。
  • 视网膜脱离比例为10%(4/41眼),其中3眼为Marfan综合征。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Evaluate long-term outcomes following Cionni modified capsule tension ring (MCTR) and in-the-bag intraocular lens (IOL) implantation in subluxated lenses. DESIGN: Retrospective case series. METHODS: Forty-one eyes of 31 patients from Raghudeep Eye Hospital, India, with subluxated lenses who had completed a minimum of 5 years' postoperative follow-up were included. Lens extraction, capsular bag fixation with MCTR using 9-0 polypropylene suture, and in-the-bag IOL implantation were performed in all eyes. Corrected distance visual acuity (CDVA), IOL centration, posterior capsule opacification, glaucoma, and retinal complications were documented at final follow-up. RESULTS: The mean age of the cohort was 20.48 ± 16.46 (SD) years. Twenty-four eyes (58%) were below 15 years of age at the time of surgery. Marfan syndrome accounted for 37% cases. Mean follow-up was 9.89 ± 3.81 (SD) years. Thirty-two eyes (74%) had a CDVA of ≥0.3 logMAR at final follow-up. IOL decentration was noted in 7 eyes (17%), requiring a secondary surgery. The mean duration from primary surgery to resurgery was 8.79 years. Seventeen eyes (41%) required a laser capsulotomy, 88% of which were pediatric eyes. Retinal detachment occurred in 4 eyes (10%), 3 of which had Marfan syndrome. CONCLUSION: Capsular bag fixation with an MCTR using 9-0 polypropylene and in-the-bag IOL implantation had good long-term visual outcomes with an acceptable rate of serious postoperative complications in eyes with subluxated lenses. This approach allows preservation of the natural compartments of the eye and placement of an IOL in its most physiological position. However, considering a 17% rate of IOL decentration requiring surgical intervention, long-term stability with nonbiodegradable suture materials such as polytetrafluoroethylene as well as decentration rates following sutured or sutureless scleral fixation should be compared.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Sandhu R, Shankar V, Vasavada V, et al. Long-Term Postoperative Outcomes Following Cionni Ring and In-the-Bag Intraocular Lens Implantation in Eyes With Subluxated Lenses. Am J Ophthalmol. 2024. PMID: 39009238. doi:10.1016/j.ajo.2024.07.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。