文献速递眼底病与葡萄膜炎

真正无反应位点区域的微视野检查特征:对萎缩型年龄相关性黄斑变性的意义

Microperimetry Characteristics of Regions With a Truly Nonresponding Location: Implications for Atrophic Age-Related Macular Degeneration.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2024-01-01

本研究基于128名双眼大玻璃膜疣参与者36个月、每6个月随访的数据构建模拟模型,模拟10万对真实微视野检查结果,分别加入或不加入一个真正无反应位点(其敏感度取自60名健康者视盘无反应位点的反应分布)。结果显示,含真正无反应位点的检查对中仅60%在两次检查均有至少1个位点<0 dB,而91%有至少1个位点≤10 dB。

要点

  • 含真正无反应位点的模拟检查对中,仅60%在两次检查均有至少1个位点<0 dB。
  • 含真正无反应位点的检查对中,91%在两次检查均有至少1个位点≤10 dB。
  • 无真正无反应位点的检查对中,符合上述三项标准的比例分别为0.04%、1.4%和0.4%。

核心结论

  • 真正无反应的测试位点区域并不几乎总是表现为可重复的绝对暗点(<0 dB),而更常表现为深度视觉敏感度缺损(≤10 dB),伴或不伴其中一次检查出现绝对暗点。
  • 若将功能标准纳入终末期萎缩型年龄相关性黄斑变性的定义,这些发现至关重要。

研究设计与样本

  • 采用模拟模型,数据来自128名基线双眼大玻璃膜疣参与者,随访36个月、每6个月一次。
  • 分别模拟10万对含或不含一个真正无反应位点的真实微视野检查结果;前者中随机选取位点的敏感度取自60名健康参与者视盘处真正无反应位点的反应分布。

主要发现

  • 含真正无反应位点的模拟检查对中,仅60%在两次检查均有至少1个位点<0 dB。
  • 含真正无反应位点的模拟检查对中,91%在两次检查均有至少1个位点≤10 dB。
  • 含真正无反应位点的模拟检查对中,87%在两次检查均有至少1个位点≤10 dB且其中一次检查<0 dB。
  • 不含真正无反应位点的模拟检查对中,符合上述三项标准的比例分别为0.04%、1.4%和0.4%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To understand the microperimetry response characteristics of regions with a truly nonresponding location, which will be useful when considering criteria for end-stage atrophic age-related macular degeneration (AMD). METHODS: A simulation model was developed using data from 128 participants with bilateral large drusen at baseline seen over 36 months at 6-month intervals. One hundred thousand pairs of real-world microperimetry testing results were simulated separately with and without one truly nonresponding location, where the sensitivity of one randomly selected location for the former group was derived from the distribution of responses from a truly nonresponding location at the optic nerve head from 60 healthy participants. RESULTS: Only 60% of the simulated test pairs with a truly nonresponding location had ≥1 location that was <0 decibel (dB) on both tests. In contrast, 91% of the simulated test pairs had ≥1 location that was ≤10 dB on both tests, and 87% had ≥1 location that was ≤10 dB on both tests and <0 dB for one of the tests. Of the simulated test pairs without a truly nonresponding location, there were 0.04%, 1.4%, and 0.4% that met these three above criteria, respectively. CONCLUSIONS: Regions with a truly nonresponding test location do not almost always show a repeatable absolute scotoma (<0 dB), but instead, much more often a deep visual sensitivity defect (≤10 dB), with or without having an absolute scotoma on one of the tests. These findings are crucial if functional criteria are to be considered as part of a definition of end-stage atrophic AMD.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Wu Z, Pfau M, Fleckenstein M, et al. Microperimetry Characteristics of Regions With a Truly Nonresponding Location: Implications for Atrophic Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2024. PMID: 39078733. doi:10.1167/iovs.65.8.44

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。