单眼视功能对比:单焦点扩展景深(EDOF)与三焦点EDOF人工晶状体植入后的对侧眼比较
这项单中心前瞻性对侧眼对照临床试验纳入25例(50眼)双眼白内障术后患者,主导眼植入单焦点EDOF Isopure人工晶状体,非主导眼植入三焦点EDOF FineVision Triumf人工晶状体,进行个体内单眼比较。结果示三焦点EDOF人工晶状体的近视力显著更优,单焦点EDOF人工晶状体在远、中距离视力上与三焦点EDOF相当,总体光现象与视功能损害程度较低。
要点
- 三焦点EDOF人工晶状体眼的单眼矫正近视力显著优于单焦点EDOF人工晶状体眼(P < .001)。
- 单焦点EDOF人工晶状体与三焦点EDOF人工晶状体的单眼最佳矫正远视力、矫正中距离视力相当(P > .05)。
- 总体观察到较低水平的光现象与视功能损害。
核心结论
- 在个体内对侧眼比较中,三焦点EDOF人工晶状体眼的近视力显著优于单焦点EDOF人工晶状体眼。
- 单焦点EDOF人工晶状体眼表现出与三焦点EDOF人工晶状体眼相似的远、中距离视力表现。
- 总体观察到较低水平的光现象与视功能损害。
研究设计与样本
- 单中心、前瞻性、对侧眼对照临床试验。
- 全部患者接受顺利的双眼白内障手术,主导眼植入单焦点EDOF Isopure人工晶状体,非主导眼植入三焦点EDOF FineVision Triumf人工晶状体。
- 共纳入25例患者(50眼)。
- 个体内单眼比较项目包括不同距离视力、离焦曲线、眼内总高阶像差、球差Z(4.0)、人工晶状体偏心与倾斜。
- 主观结局采用光晕与眩光模拟及七项视功能指数量表评估。
主要发现
- 个体内单眼最佳矫正远视力、矫正中距离视力及最佳矫正近视力在三焦点EDOF人工晶状体眼与单焦点EDOF人工晶状体眼之间相当(P > .05)。
- 单眼对比视力(P = .019)、矫正近视力(P < .001)以及0.0 D离焦水平(P = .005)和-1.5至-4.0 D之间离焦曲线(P < .001)在三焦点EDOF人工晶状体眼与单焦点EDOF人工晶状体眼之间差异有统计学意义。
- 5 mm瞳孔直径下眼内高阶像差与球差Z(4.0)在三焦点EDOF人工晶状体眼与单焦点EDOF人工晶状体眼之间差异有统计学意义(P < .001),3 mm瞳孔直径下二者相当,人工晶状体倾斜与偏心亦相当(P > .05)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare intraindividual monocular visual performance of a monofocal extended depth-of-focus (EDOF) and a trifocal EDOF intraocular lens (IOL) following bilateral cataract surgery. DESIGN: Single-center, prospective, fellow-eye comparison clinical trial. METHODS: All patients received uneventful bilateral cataract surgery with implantation of the monofocal EDOF Isopure IOL in the dominant eye and the trifocal EDOF FineVision Triumf IOL in the nondominant eye. Intraindividual monocular comparison included visual acuity at various distances, defocus curves, internal total higher-order aberration (HOA), spherical aberration (SA) Z(4.0), IOL decentration, and tilt. Additionally, subjective outcomes were evaluated using Halo and Glare simulation and the Seven-Item Visual-Functioning Index questionnaire. RESULTS: In total, 25 patients (50 eyes) were included. Intraindividual monocular best-corrected distance visual acuity, distance-corrected intermediate visual acuity, and best-corrected near visual acuity were comparable (P > .05). However, monocular contrast acuity (P = .019), distance-corrected near visual acuity (P < .001), and defocus curves at defocus levels of 0.0 D (P = .005) and between -1.5 and -4.0 D (P < .001) differed significantly. At 5 mm, internal HOA and SA Z(4.0) were significantly different (P < .001) and comparable at 3-mm pupil diameter, as were IOL tilt and decentration (P > .05). CONCLUSION: In this combined fellow-eye comparison, near vision was significantly better with the trifocal EDOF IOL. The monofocal EDOF IOL demonstrated similar distance and intermediate visual performance as the trifocal EDOF IOL. Overall, low values of photic phenomena and visual impairment were observed.
引用
- Danzinger V, Schartmüller D, Lisy M, et al. Fellow-Eye Comparison of Monocular Visual Outcomes Following Monofocal Extended Depth-of-Focus (EDOF) and Trifocal EDOF Intraocular Lens Implantation. Am J Ophthalmol. 2024. PMID: 38851443. doi:10.1016/j.ajo.2024.05.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。