在电子健康记录关联的生物样本库中使用诊断代码构建原发性开角型青光眼多基因风险评分
该回顾性队列研究在Mount Sinai BioMe和Mass General Brigham两个生物样本库中,比较了基于ICD代码与人工病历复核定义的原发性开角型青光眼(POAG)多基因风险评分(PRS)性能。结果显示两种定义方式下PRS的AUC在各 ancestry 组间均无统计学显著差异,但ICD代码的特异性较低(44%-53%)。
要点
- 在BioMe和MGB中,ICD代码识别POAG的阳性预测值分别为53%和55%,阴性预测值分别为96%和97%。
- ICD代码识别POAG的敏感性在BioMe和MGB均为97%,特异性分别为44%和53%。
- 基于ICD代码与人工复核的PRS AUC在各 ancestry 组间均无统计学显著差异(BioMe P≥.21,MGB P≥.18)。
核心结论
- 在2个电子健康记录关联的生物样本库中,使用人工复核或ICD代码定义的POAG PRS表现相似;对于某些PRS研究,可能不需要人工评估青光眼状态。
- 鉴于ICD代码对人工确认的青光眼病例特异性低(44%-53%),使用ICD代码进行青光眼诊断时应谨慎。
研究设计与样本
- 回顾性队列研究,在Mount Sinai BioMe和Mass General Brigham(MGB)生物样本库中使用ICD代码识别POAG病例。
- 基于光学相干断层扫描和视野检查确认POAG;在单独的5%样本中,使用眼压和杯盘比标准确认无POAG。
- 使用基因型数据及UK Biobank中自报青光眼诊断或ICD-10青光眼诊断代码,采用lassosum方法计算全基因组POAG PRS。
- 比较基于ICD代码与病历复核的POAG预测的曲线下面积(AUC)。
- 复核了BioMe中996例ICD识别病例中的804例和MGB中1006例中的367例。
主要发现
- 在BioMe和MGB中,阳性预测值分别为53%和55%,阴性预测值分别为96%和97%,敏感性分别为97%和97%,特异性分别为44%和53%。
- 在BioMe中,基于ICD代码与人工病历复核的调整后PRS AUC按 ancestry 分别为:非洲裔0.77 vs 0.75,西班牙裔0.80 vs 0.80,欧洲裔0.81 vs 0.81,均无统计学显著差异(P≥.21)。
- 在MGB中,基于ICD代码与人工病历复核的调整后PRS AUC按 ancestry 分别为:非洲裔0.72 vs 0.80,西班牙裔0.83 vs 0.86,欧洲裔0.74 vs 0.73,均无统计学显著差异(P≥.18)。
临床怎么用
- 作者认为,对于某些PRS研究,可能不需要人工评估青光眼状态。
- 作者指出,鉴于ICD代码对人工确认的青光眼病例特异性低(44%-53%),使用ICD代码进行青光眼诊断时应谨慎。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Polygenic risk scores (PRSs) likely predict risk and prognosis of glaucoma. We compared the PRS performance for primary open-angle glaucoma (POAG), defined using International Classification of Diseases (ICD) codes vs manual medical record review. DESIGN: Retrospective cohort study. METHODS: We identified POAG cases in the Mount Sinai BioMe and Mass General Brigham (MGB) biobanks using ICD codes. We confirmed POAG based on optical coherence tomograms and visual fields. In a separate 5% sample, the absence of POAG was confirmed with intraocular pressure and cup-disc ratio criteria. We used genotype data and either self-reported glaucoma diagnoses or ICD-10 codes for glaucoma diagnoses from the UK Biobank and the lassosum method to compute a genome-wide POAG PRS. We compared the area under the curve (AUC) for POAG prediction based on ICD codes vs medical records. RESULTS: We reviewed 804 of 996 BioMe and 367 of 1006 MGB ICD-identified cases. In BioMe and MGB, respectively, positive predictive value was 53% and 55%; negative predictive value was 96% and 97%; sensitivity was 97% and 97%; and specificity was 44% and 53%. Adjusted PRS AUCs for POAG using ICD codes vs manual record review in BioMe were not statistically different (P ≥.21) by ancestry: 0.77 vs 0.75 for African, 0.80 vs 0.80 for Hispanic, and 0.81 vs 0.81 for European. Results were similar in MGB (P ≥.18): 0.72 vs 0.80 for African, 0.83 vs 0.86 for Hispanic, and 0.74 vs 0.73 for European. CONCLUSIONS: A POAG PRS performed similarly using either manual review or ICD codes in 2 electronic health record-linked biobanks; manual assessment of glaucoma status might not be necessary for some PRS studies. However, caution should be exercised when using ICD codes for glaucoma diagnosis given their low specificity (44%-53%) for manually confirmed cases of glaucoma.
引用
- Tran JH, Kang J, Han E, et al. Use of Diagnostic Codes for Primary Open-Angle Glaucoma Polygenic Risk Score Construction in Electronic Health Record-Linked Biobanks. Am J Ophthalmol. 2024. PMID: 38906208. doi:10.1016/j.ajo.2024.06.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。