基于深度学习的眼眶肌肉与脂肪自动分割及体积定量分析用于甲状腺眼病诊断
本研究纳入281例受试者,采用U-Net深度学习模型在眼眶CT上自动分割眼眶肌肉与脂肪体积,肌肉和脂肪的Dice系数分别为0.902和0.921。正常、轻度TED和重度TED(伴压迫性视神经病变)三组间肌肉体积存在统计学差异,基于体积数据与有限患者数据的随机森林分类器预测三类的准确率为0.838,AUC为0.929。
要点
- U-Net自动分割眼眶CT肌肉和脂肪的Dice系数分别为0.902和0.921
- 正常、轻度TED与重度TED(伴CON)三组间肌肉体积存在统计学差异
- ML分类器预测正常、轻度TED和重度TED的准确率为0.838,AUC为0.929
核心结论
- 基于深度学习的眼眶图像自动分割用于TED患者是准确且高效的。
- 使用体积数据与元数据的机器学习分类模型在区分TED与伴CON的TED方面具有高诊断准确率。
- 通过实现快速且精确的体积评估,该工具可能在未来临床研究中有用。
研究设计与样本
- 纳入接受临床评估和眼眶CT成像的TED受试者,有CON临床特征者归为重度TED,无者归为轻度TED,正常受试者作为对照。
- 采用U-Net深度学习模型对眼眶CT中的眼眶肌肉和脂肪体积进行自动分割,并采用随机森林分类器集成进行肌肉和脂肪的体积分析。
- 共纳入281例受试者。
主要发现
- 眼眶组织自动分割的Dice系数肌肉为0.902、脂肪为0.921。
- 正常、轻度TED和重度TED三组间肌肉体积存在统计学差异。
- 利用体积数据和有限患者数据的分类模型预测正常、轻度TED和重度TED的准确率为0.838,AUC为0.929。
关键数值与推荐
- 肌肉分割Dice系数0.902,脂肪分割Dice系数0.921。
- 分类模型预测正常、轻度TED和重度TED的准确率0.838,AUC 0.929。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Thyroid eye disease (TED) is characterized by proliferation of orbital tissues and complicated by compressive optic neuropathy (CON). This study aims to utilize a deep-learning (DL)-based automated segmentation model to segment orbital muscle and fat volumes on computed tomography (CT) images and provide quantitative volumetric data and a machine learning (ML)-based classifier to distinguish between TED and TED with CON. METHODS: Subjects with TED who underwent clinical evaluation and orbital CT imaging were included. Patients with clinical features of CON were classified as having severe TED, and those without were classified as having mild TED. Normal subjects were used for controls. A U-Net DL-model was used for automatic segmentation of orbital muscle and fat volumes from orbital CTs, and ensemble of Random Forest Classifiers were used for volumetric analysis of muscle and fat. RESULTS: Two hundred eighty-one subjects were included in this study. Automatic segmentation of orbital tissues was performed. Dice coefficient was recorded to be 0.902 and 0.921 for muscle and fat volumes, respectively. Muscle volumes among normal, mild, and severe TED were found to be statistically different. A classification model utilizing volume data and limited patient data had an accuracy of 0.838 and an area under the curve (AUC) of 0.929 in predicting normal, mild TED, and severe TED. CONCLUSIONS: DL-based automated segmentation of orbital images for patients with TED was found to be accurate and efficient. An ML-based classification model using volumetrics and metadata led to high diagnostic accuracy in distinguishing TED and TED with CON. By enabling rapid and precise volumetric assessment, this may be a useful tool in future clinical studies.
引用
- Alkhadrawi AM, Lin LY, Langarica SA, et al. Deep-Learning Based Automated Segmentation and Quantitative Volumetric Analysis of Orbital Muscle and Fat for Diagnosis of Thyroid Eye Disease. Invest Ophthalmol Vis Sci. 2024. PMID: 38696188. doi:10.1167/iovs.65.5.6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。