文献速递青光眼

结构与功能青光眼检测的一致频率:3D OCT与当前临床检测的纵向研究

Frequency of Agreement Between Structural and Functional Glaucoma Testing: A Longitudinal Study of 3D OCT and Current Clinical Tests.
PubMed 文献 · Am J Ophthalmol · 2024-05-27

前瞻性队列研究纳入124只开角型青光眼眼,平均随访66.9±16.4个月,评估结构检测(视盘照相、RNFL厚度、3D OCT最小距离带)与功能检测(Humphrey视野)在同一次随访中同时发现进展的频率。结构检测与视野在同次随访一致进展的比例仅5.0%(3/60)至16.0%(13/81)。结论认为结构与功能检测通常不在同一次就诊中同时进展,多数情况下青光眼进展仅由一或两种检测发现。

要点

  • 结构检测与视野在同次随访一致进展的比例为5.0%(3/60)至16.0%(13/81)。
  • 全局MDB厚度与视野一致率为16.0%(13/81),全局RNFL厚度为8.3%(7/84)。
  • 全局MDB厚度与视野的一致率优于视盘照相与视野(5.0%[3/60],P=0.04)。

核心结论

  • 结构检测与功能检测通常不在同一次门诊随访中同时发现青光眼进展,多数情况下进展仅由一或两种检测发现。

研究设计与样本

  • 前瞻性队列研究,纳入单一机构的124例开角型青光眼患者,每例随机选取一只眼,要求至少有4次年度研究随访。
  • 研究随访包括散瞳眼底检查、视盘照相、Humphrey视野24-2、2D OCT视网膜神经纤维层厚度测量和3D OCT神经视网膜边缘测量(最小距离带,MDB)。
  • 每次随访对每种检测采用基于事件的分析将眼分类为进展者或非进展者,若同一眼在同次随访中两种检测均进展则记为一致。

主要发现

  • 124只开角型青光眼眼平均随访66.9±16.4个月。
  • 结构检测(视盘照相、全局RNFL厚度、全局MDB边缘厚度)与功能检测(HVF)在同次随访一致进展的比例仅为5.0%(3/60)至16.0%(13/81)。
  • 全局MDB厚度与HVF的一致率为16.0%(13/81),全局RNFL厚度与HVF的一致率为8.3%(7/84)。
  • 全局MDB厚度与HVF的结构-功能一致率优于视盘照相与HVF(5.0%[3/60],P=0.04)。
  • 在所有检测方法的两两比较中,中度青光眼眼的一致率与轻度或重度青光眼眼相似或更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate how often tests of structure and function detect glaucoma progression at the same study visit. Tests include current glaucoma clinical tests and a new 3-dimensional (3D) optical coherence tomography (OCT) rim measurement. DESIGN: Prospective cohort study. METHODS: For 124 open-angle glaucoma patients at a single institution, one eye was randomly selected for each patient. Patients were included if they had open-angle glaucoma and if they had at least 4 yearly study visits. Study visits included a full dilated eye exam, disc photography (DP), Humphrey visual field (HVF 24-2) testing, 2D OCT retinal nerve fibre layer (RNFL) thickness measurements, and 3D OCT neuroretinal rim measurements (i.e., minimum distance band or MDB). For each test at each study visit, eyes were classified as progressors or non-progressors using event-based analysis. Agreement occurred if tests progressed in the same eye at the same study visit. Agreements between all compared tests were calculated as percentages of agreement. RESULTS: The study included 124 open-angle glaucoma eyes, which had an average follow-up period of 66.9 ± 16.4 months. Structural tests (i.e., DP, global RNFL thickness, and global MDB rim thickness) progressed at the same visit as the functional test (i.e., HVF testing) in only 5.0% (3/60) to 16.0% (13/81) of eyes. Global MDB thickness and global RNFL thickness showed similar agreement with functional HVF testing (i.e., 16.0% [13/81] and 8.3% [7/84], respectively), and global MDB thickness showed better structure-function agreement with HVF testing than between DP and HVF testing (i.e., 5.0% [3/60], P = 0.04). For all paired comparisons between testing methods, eyes with moderate glaucoma showed similar or better agreement than eyes with mild or severe glaucoma. CONCLUSIONS: Clinical tests of structure and function do not usually progress at the same clinic visit. Most of the time, glaucoma progression is only detected by one or two tests.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Manik D, Ratanawongphaibul K, Kim J, et al. Frequency of Agreement Between Structural and Functional Glaucoma Testing: A Longitudinal Study of 3D OCT and Current Clinical Tests. Am J Ophthalmol. 2024. PMID: 38810864. doi:10.1016/j.ajo.2024.05.018