角膜与视神经乳头之间的生物力学相关性
研究对9对供体眼球行膨胀试验,眼压从5 mmHg以0.5 mmHg步进升至30 mmHg,用50 MHz超声散斑追踪测量角膜与视神经乳头及筛板周围巩膜的应变。结果显示角膜剪切应变与视神经乳头剪切应变(R=0.857,P=0.003)及筛板周围巩膜剪切应变(R=0.724,P=0.028)显著相关,而中央角膜厚度与任何应变均无相关性。作者认为角膜剪切应变较大的眼在眼压升高时其视神经乳头和筛板周围巩膜剪切应变也可能较大。
要点
- 角膜剪切应变与视神经乳头剪切应变显著相关(R=0.857,P=0.003)。
- 角膜剪切应变与筛板周围巩膜剪切应变显著相关(R=0.724,P=0.028)。
- 中央角膜厚度与角膜、视神经乳头或筛板周围巩膜的任一应变均无相关性。
核心结论
- 作者认为,在眼压升高时角膜剪切应变较大的眼,其视神经乳头和筛板周围巩膜的剪切应变也可能较大。
- 角膜与视神经乳头对眼压的剪切反应之间的强相关性为角膜与青光眼风险的关联提供了一种可能的解释。
研究设计与样本
- 在9对供体人眼上行膨胀试验,每对眼中一只眼随机分配用于角膜或后眼膨胀。
- 眼压从5 mmHg以0.5 mmHg步进升至30 mmHg,用50 MHz超声探头成像角膜或视神经乳头/筛板周围巩膜。
- 采用基于相关性的超声散斑追踪计算组织位移和应变,评估30 mmHg时角膜与视神经乳头或筛板周围巩膜的径向、切向和剪切应变之间的关联。
主要发现
- 角膜剪切应变与视神经乳头剪切应变显著相关(R=0.857,P=0.003)。
- 角膜剪切应变与筛板周围巩膜剪切应变显著相关(R=0.724,P=0.028)。
- 中央角膜厚度与角膜、视神经乳头或筛板周围巩膜的任何应变均无相关性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. METHODS: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. RESULTS: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. CONCLUSIONS: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.
引用
- Pan M, Kwok S, Pan X, et al. Biomechanical Correlations Between the Cornea and the Optic Nerve Head. Invest Ophthalmol Vis Sci. 2024. PMID: 38776117. doi:10.1167/iovs.65.5.34
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。