文献速递青光眼

使用房角镜、SLT透镜和激光虹膜切开透镜时的眼内压:一项离体研究

Intraocular Pressure While Using Gonioscopy, SLT, and Laser Iridotomy Lenses: An Ex Vivo Study.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2024-01-01

该离体研究将12只尸体眼安装于定制装置并连接压力传感器,由6名眼科医生分别模拟使用Sussman四面镜行房角镜检查、Latina透镜行选择性激光小梁成形术(SLT)及Abraham透镜行激光虹膜切开。结果显示三种操作平均眼内压分别为43.2±16.9 mmHg、39.8±9.9 mmHg和42.7±12.6 mmHg,较基线约升高20 mmHg;Sussman透镜施加于眼球的平均力显著低于Latina透镜(P=0.0008)和Abraham透镜(P=0.001)。

要点

  • 在尸体眼上使用标准眼科操作透镜可使眼内压较基线升高约20 mmHg。
  • 房角镜、SLT透镜和激光虹膜切开透镜操作时平均眼内压分别为43.2±16.9 mmHg、39.8±9.9 mmHg和42.7±12.6 mmHg。
  • Sussman透镜施加于眼球的平均力显著低于Latina透镜(P=0.0008)和Abraham透镜(P=0.001)。

核心结论

  • 在尸体眼上,使用标准眼科操作透镜可使眼内压较基线升高约20 mmHg。

研究设计与样本

  • 离体研究,将12只尸体眼安装于定制装置并经插管连接压力传感器测量眼内压,装置安装于测力传感器上测量施加于眼球的力。
  • 由6名眼科医生分别模拟房角镜检查(Sussman四面镜)、SLT(Latina透镜)和激光虹膜切开(Abraham透镜),计算机记录眼内压(mmHg)和力(g)。

主要发现

  • 房角镜检查、SLT和激光虹膜切开期间的平均眼内压分别为43.2±16.9 mmHg、39.8±9.9 mmHg和42.7±12.6 mmHg。
  • Sussman透镜、Latina透镜和Abraham透镜施加于眼球的平均力分别为40.3±26.4 g、66.7±29.8 g和65.5±35.9 g。
  • Sussman透镜施加于眼球的平均力显著低于Latina透镜(P=0.0008)和Abraham透镜(P=0.001)。
  • 房角镜压陷期间眼内压平均升高至80.5±22.6 mmHg。
  • 模拟激光虹膜切开填压期间眼内压平均升高至82.3±27.2 mmHg。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses. METHODS: Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures. RESULTS: The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg. CONCLUSIONS: In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. De Francesco T, Mikula E, Lummis W, et al. Intraocular Pressure While Using Gonioscopy, SLT, and Laser Iridotomy Lenses: An Ex Vivo Study. Invest Ophthalmol Vis Sci. 2024. PMID: 38713484. doi:10.1167/iovs.65.5.13

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。