文献速递眼底病与葡萄膜炎

玻璃体切除术联合硅油或气体填充治疗非复杂性视网膜脱离:系统综述与荟萃分析

Pars Plana Vitrectomy With Silicone Oil or Gas Tamponade for Uncomplicated Retinal Detachment: A Systematic Review and Meta-Analysis.
PubMed 文献 · Am J Ophthalmol · 2024-05-28

该系统综述与荟萃分析纳入9项观察性研究共491只视网膜脱离眼,比较玻璃体切除术联合硅油与气体填充的疗效与安全性。气体填充组末次随访最佳矫正视力显著优于硅油组(加权均数差0.17 logMAR),两组初次视网膜复位率相似;硅油组神经节细胞层、内丛状层和外核层显著更薄。作者指出缺乏随机试验及选择偏倚可能,需在多样化人群中进一步研究。

要点

  • 气体填充组末次随访最佳矫正视力显著优于硅油组,加权均数差0.17 logMAR(95%CI 0.06–0.27,P=0.002)。
  • 硅油组与气体填充组初次视网膜复位率相似(P=0.89)。
  • 硅油组神经节细胞层、内丛状层和外核层厚度显著薄于气体填充组。

核心结论

  • 玻璃体切除术联合气体填充相比联合硅油填充与更好的功能结局相关,但两种填充方式的初次视网膜复位率相当。
  • 缺乏随机试验和潜在选择偏倚凸显了在多样化患者人群中进一步研究的重要性。

研究设计与样本

  • 系统综述与荟萃分析,检索Ovid MEDLINE、Embase和Cochrane Library从2000年1月至2023年9月的比较研究。
  • 纳入9项观察性研究,共报告491只视网膜脱离眼。
  • 采用随机效应模型进行荟萃分析。

主要发现

  • 末次研究观察时平均最佳矫正视力气体填充组显著优于硅油组(加权均数差0.17 logMAR,95%CI 0.06–0.27,P=0.002)。
  • 初次视网膜复位率硅油组与气体填充组相似(P=0.89)。
  • 神经节细胞层硅油组显著薄于气体填充组(加权均数差-3.70 µm,95%CI -5.87至-1.53,P=0.0008)。
  • 内丛状层硅油组显著薄于气体填充组(加权均数差-2.45,95%CI -4.50至-0.40,P=0.02)。
  • 外核层硅油组显著薄于气体填充组(加权均数差-11.74 µm,95%CI -18.39至-5.10,P=0.0005)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 缺乏随机试验。
  • 存在潜在选择偏倚。
  • 需要在多样化患者人群中进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the efficacy and safety of pars plana vitrectomy (PPV) with silicone oil compared to gas tamponade for uncomplicated rhegmatogenous retinal detachment (RRD). DESIGN: Systematic review and meta-analysis. METHODS: A systematic literature search was conducted on Ovid MEDLINE, Embase, and the Cochrane Library from January 2000 to September 2023 for comparative studies evaluating the efficacy and safety of PPV with either silicone oil or gas tamponade in the setting of uncomplicated RRD. Our primary outcome was best-corrected visual acuity at the last study observation. Secondary outcomes included the rates of retinal reattachment, retinal thickness, and the incidence of adverse events. We performed a meta-analysis using a random-effects model. RESULTS: Nine observational studies reporting on 491 RRD eyes were included. The mean best-corrected visual acuity at the last study observation was significantly better in the gas tamponade group than in the silicone oil group (weighted mean difference [WMD] = 0.17 logMAR, 95% confidence interval [CI] = [0.06, 0.27], P = .002). Rates of primary retinal reattachment were similar between the silicone oil and gas tamponade groups (P = .89). The ganglion cell layer was significantly thinner in the silicone oil group compared to the gas tamponade group (WMD =-3.70 µm, 95% CI = [-5.87, -1.53, P = .0008), as was the inner plexiform layer (WMD = -2.45, 95% CI = [-4.50, -0.40], P = .02) and outer nuclear layer (WMD = -11.74 µm, 95% CI = [-18.39, -5.10], P = .0005). CONCLUSIONS: PPV with gas tamponade was associated with better functional outcomes compared to PPV with silicone oil, although both tamponades yielded comparable primary reattachment rates. The absence of randomized trials and the potential for selection bias underscore the importance of further investigation in diverse patient populations.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Huang RS, Mihalache A, Lau THA, et al. Pars Plana Vitrectomy With Silicone Oil or Gas Tamponade for Uncomplicated Retinal Detachment: A Systematic Review and Meta-Analysis. Am J Ophthalmol. 2024. PMID: 38815844. doi:10.1016/j.ajo.2024.05.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。