瞳孔与晶状体扫视后振荡降低视网膜色素变性和年龄相关性黄斑变性患者的注视稳定性
本研究用基于瞳孔的眼动仪记录水平扫视任务,比较年龄相关性黄斑变性(AMD,n=6)、视网膜色素变性(RP,n=5)与正常视力者(NV,n=7)扫视后80至200毫秒振荡(PSO)的振幅、衰减时间常数和频率。视力丧失者PSO振幅更大、衰减常数更长、频率更低;振荡振幅随扫视减速增加而增大,其他PSO参数与扫视振幅或峰值速度无一致相关。作者认为AMD和RP的扫视后注视稳定性因异常PSO而降低,差异并非源于扫视动力学。
要点
- AMD与RP患者的PSO振幅大于NV者,衰减常数更长、频率更低。
- 三组中PSO振幅均随扫视减速增加而增大。
- 其他PSO参数与扫视振幅或峰值速度无一致相关。
核心结论
- AMD和RP的扫视后注视稳定性因异常PSO而降低,与NV的差异并非源于扫视动力学差异,提示解剖和神经元变异影响患者眼内虹膜与晶状体的悬吊。
研究设计与样本
- 参与者完成水平扫视任务,用基于瞳孔的眼动仪测量注视。
- 以阻尼振荡模型描述扫视后80至200毫秒期间的振荡。
- 比较AMD(n=6)、RP(n=5)与NV(n=7)三组的PSO振幅、衰减时间常数和频率。
主要发现
- 视力丧失者(AMD n=6,RP n=5)较NV者(n=7)振荡振幅更大、衰减常数更长、频率更低。
- 三组中振荡振幅均随扫视减速增加而增大。
- 其他PSO参数与扫视振幅或峰值速度均无一致相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Post-saccadic oscillations (PSOs) reflect movements of gaze that result from motion of the pupil and lens relative to the eyeball rather than eyeball rotations. Here, we analyzed the characteristics of PSOs in subjects with age-related macular degeneration (AMD), retinitis pigmentosa (RP), and normal vision (NV). Our aim was to assess the differences in PSOs between people with vision loss and healthy controls because PSOs affect retinal image stability after each saccade. METHODS: Participants completed a horizontal saccade task and their gaze was measured using a pupil-based eye tracker. Oscillations occurring in the 80 to 200 ms post-saccadic period were described with a damped oscillation model. We compared the amplitude, decay time constant, and frequency of the PSOs for the three different groups. We also examined the correlation between these PSO parameters and the amplitude, peak velocity, and final deceleration of the preceding saccades. RESULTS: Subjects with vision loss (AMD, n = 6, and RP, n = 5) had larger oscillation amplitudes, longer decay constants, and lower frequencies than subjects with NV (n = 7). The oscillation amplitudes increased with increases in saccade deceleration in all three groups. The other PSO parameters, however, did not show consistent correlations with either saccade amplitude or peak velocity. CONCLUSIONS: Post-saccadic fixation stability in AMD and RP is reduced due to abnormal PSOs. The differences with respect to NV are not due to differences in saccade kinematics, suggesting that anatomic and neuronal variations affect the suspension of the iris and the lens in the patients' eyes.
引用
- Guadron L, Titchener SA, Abbott CJ, et al. Post-Saccadic Oscillations of the Pupil and Lens Reduce Fixation Stability in Retinitis Pigmentosa and Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2024. PMID: 38787546. doi:10.1167/iovs.65.5.39
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。