糖尿病眼表氧摄取缺陷经光纤微传感器揭示
研究使用光纤氧微传感器(optrode)在链脲佐菌素(STZ)诱导糖尿病小鼠中评估眼表氧摄取时空特征,发现糖尿病角膜在球结膜和角膜缘的氧消耗显著低于对照,而中央和周边角膜无显著差异,且夜间角膜缘氧消耗不似正常对照那样升高。
要点
- 糖尿病小鼠眼表整体氧摄取减少且失去健康眼表独特的时空分布模式。
- 糖尿病角膜在球结膜和角膜缘的氧消耗显著低于对照,中央和周边角膜无显著差异。
- 健康角膜夜间角膜缘氧消耗升高,糖尿病角膜无此升高。
核心结论
- 糖尿病角膜存在先前未知的氧摄取损害,可能成为诊断眼表异常的工具并提示新的病因机制。
研究设计与样本
- 使用光纤氧微传感器(optrode)在链脲佐菌素(STZ)诱导的糖尿病小鼠中评估眼表氧摄取的时空分布。
主要发现
- 糖尿病小鼠眼表氧摄取减少且失去健康眼表独特的时空分布模式。
- 糖尿病角膜在球结膜和角膜缘的氧消耗显著低于对照,而中央和周边角膜与对照无显著差异。
- 健康角膜在夜间角膜缘氧消耗升高,糖尿病角膜则无此升高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Diabetes mellitus causes diabetic keratopathy (DK). This and other ocular surface disorders are underdiagnosed and problematic for affected patients as well as recipients of diabetic donor corneas. Thus, it is important to find noninvasive means to facilitate determination of the potentially vision-threatening DK. It has been reported that diabetic corneas uptake significantly less oxygen (O2) than healthy controls. However, an integral assessment of the ocular surface is missing. METHODS: Using an optic-fiber O2 micro-sensor (optrode) we demonstrated recently that the healthy ocular surface displays a unique spatiotemporal map of O2 consumption. We hypothesize that diabetes impairs the spatiotemporal profile of O2 uptake at the ocular surface. RESULTS: Using streptozotocin (STZ)-induced diabetic mice, we found diminished O2 uptake and loss of the unique pattern across the ocular surface. A diabetic cornea consumes significantly less O2 at the bulbar conjunctiva and limbus, but not the central and peripheral cornea, compared to controls. Further, we show that, contrary to the healthy cornea, the diabetic cornea does not increase the O2 consumption at the limbus in the evening as the normal control. CONCLUSIONS: Altogether, our measurements reveal a previously unknown impairment in O2 uptake at the diabetic cornea, making it a potential tool to diagnose ocular surface abnormalities and suggesting a new etiology mechanism.
引用
- Qin S, Ma L, Ferreira F, et al. Diabetic Ocular Surface Has Defects in Oxygen Uptake Revealed by Optic Fiber Microsensor. Invest Ophthalmol Vis Sci. 2024. PMID: 38506851. doi:10.1167/iovs.65.3.27
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。