儿童双侧白内障术后眼球轴长预测模型的外部验证
本研究对一预测2岁以上儿童双侧白内障行一期人工晶状体植入术后轴长的模型进行外部验证,纳入30例患儿55眼、179次随访。模型估计轴长与实测轴长中位数分别为22.16 mm与22.37 mm,Pearson系数0.9534,Lin相关0.9258,Bland-Altman 95%一致性界限为0.71至-1.19。结论认为该模型外部效度良好。
要点
- 模型估计与实测轴长中位数分别为22.16 mm与22.37 mm,Pearson系数0.9534。
- Bland-Altman分析95%一致性界限为0.71至-1.19。
- 末次随访实测与估计轴长中位数分别为22.69 mm与22.43 mm。
核心结论
- 作者既往开发的眼球轴长生长预测模型在验证队列中能准确预测随生长变化的实测轴长,显示出良好的外部效度。
研究设计与样本
- 采用回顾性病例序列的外部验证研究,在年龄、双侧白内障、一期人工晶状体植入及随访评估特征相同但人群不同的队列中估计轴长,并与随访实测轴长比较。
主要发现
- 共纳入30例患儿的55眼,其中5例双侧白内障患儿仅纳入1眼,手术时中位年龄5.01岁,获得179次随访轴长测量,末次随访中位年龄10.15岁。
- 所有随访中实测与模型估计轴长中位数分别为22.37 mm与22.16 mm,Pearson系数0.9534,Lin相关0.9258。
- Bland-Altman分析中两种方法(实测与估计轴长)的95%一致性界限为0.71至-1.19。
- 3眼(1.68%)轴长短于21.2 mm时差值大于0.71,9眼(5.03%)轴长长于22.5 mm时差值小于-1.19。
- 末次随访实测与估计轴长中位数分别为22.69 mm与22.43 mm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To perform the external validation of a model to predict postoperative axial length (AL) in children over 2 years of age who were undergoing bilateral cataract surgery with primary intraocular lens (IOL) implantation. DESIGN: Validation study using a retrospective case series. METHODS: Using a population different from the one that created the model, but with the same characteristics regarding age, bilateral cataract, primary IOL implantation, and follow-up assessment, AL was estimated. The AL values estimated by the model were compared with the AL measured in the follow-ups. RESULTS: In all, 55 eyes of 30 children were selected for this study; in 5 children with bilateral cataracts, only 1 eye was included. The median age at the time of surgery was 5.01 years. Follow-up AL measurements were obtained for 179 visits. The median age at the final follow-up visit was 10.15 years. The median AL measured and estimated by the model in all visits were 22.37 mm and 22.16 mm, respectively (Pearson coefficient: 0.9534; Lin correlation: 0.9258). In the Bland-Altman analysis, the 95% limit of agreement between the 2 methods (measured and estimated AL) was 0.71 to -1.19. In 3 eyes (1.68%) with AL shorter than 21.2 mm, the difference was >0.71, and in 9 eyes with AL longer than 22.5 (5.03%), it was less than -1.19. The median AL measured and estimated at the final visit were 22.69 mm and 22.43 mm, respectively. CONCLUSION: Our previously developed prediction model for globe AL growth demonstrated good external validity by accurately predicting measured AL changes with growth in the validation cohort.
引用
- Lottelli AC, Trivedi RH, Jorge EC, et al. External Validation of a Model to Predict Postoperative Globe Axial Length in Children After Bilateral Cataract Surgery. Am J Ophthalmol. 2024. PMID: 38521155. doi:10.1016/j.ajo.2024.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。