人工晶状体植入术后患者周边视觉:系统综述与Meta分析
该系统综述与Meta分析更新了人工晶状体(IOL)植入术后周边光学与视觉的文献,纳入47项研究共5963例参与者(其中15项进入Meta分析)。结果显示,无论IOL设计如何,视野测量所得平均偏差(MD)汇总估计值似低于健康年龄匹配对照,而FDT检测的局部缺损(PSD)汇总估计值高于对照;假晶状体眼从20°起周边散光增加并出现近视漂移,周边像质较有晶状体眼下降。患者报告周边视觉满意度高,但周边像质下降是否导致周边视功能受损尚需进一步研究。
要点
- Meta分析显示,无论IOL设计如何,视野计测得的MD汇总估计值似低于健康年龄匹配对照。
- FDT检测的PSD汇总估计值高于健康年龄匹配对照,提示局部缺损更多。
- 假晶状体眼从20°起周边散光增加并出现近视漂移,周边像质较有晶状体眼下降。
核心结论
- 白内障术后眼周边像质下降,但这种下降是否导致周边视功能受损尚需进一步研究。
研究设计与样本
- 系统检索PubMed、Cochrane对照试验中心注册库、Embase及灰色文献,纳入随机对照试验和观察性研究。
- 最终纳入47项研究共5963例参与者,其中15项纳入Meta分析。
- 周边视觉定义为中央凹区域以外(偏心度超过4-5°)的视觉。
主要发现
- 视野方面,Meta分析显示无论IOL设计如何,视野计(SAP、SWAP、FDT)测得的MD汇总估计值似低于健康年龄匹配对照的均值。
- FDT检测的PSD汇总估计值高于健康年龄匹配对照。
- 假晶状体眼从20°起周边散光增加并出现近视漂移,周边像质较有晶状体眼下降。
- 患者报告周边视觉的汇总评分估计值为95.19,提示满意度高;Steps & Stairs问题的汇总评分估计值为0.23,提示看台阶和楼梯无困难至轻度困难。
局限性
- 周边像质下降是否导致周边视功能受损尚需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To update the literature on peripheral optics and vision following intraocular lens (IOLs) implantation. METHODS: We investigated how current IOLs influence peripheral visual function, peripheral optical quality, and visual perception and performance, in patients following cataract surgery. Peripheral vision is described as vision outside the central foveal region of the eye (beyond 4-5° of eccentricity). We systematically searched PubMed, Cochrane Central Register of Controlled Trials, Embase, and gray literature for relevant references. Randomized controlled trials and observational studies were eligible for inclusion. Finally, 47 studies with a total of 5963 participants were eligible for this review, of which 15 were included in the meta-analysis. RESULTS: Regarding visual fields, the meta-analysis showed that the pooled estimate of mean deviation (MD) measured with perimetry tests (standard automated perimetry [SAP], short-wavelength automated perimetry [SWAP], and frequency doubling technology [FDT]) appears to be lower than the mean of healthy age-matched controls, regardless of IOL design. Results for pooled estimate show that localized defects (pattern standard deviation [PSD]) were higher than those in the healthy age-matched controls for FDT. We also collected evidence demonstrating that pseudophakia increases peripheral astigmatism and a myopic shift from 20° onward, leading to decreased peripheral image quality compared with that in phakic eyes. Patient-reported outcomes on peripheral vision showed a pooled score estimate of 95.19, indicating high satisfaction, and for the Steps & Stairs questions, a pooled score estimate at 0.23, indicating no to little difficulty seeing steps and stairs. CONCLUSIONS: Peripheral image quality is degraded in eyes after cataract surgery. Nevertheless, whether this degradation leads to impaired visual function in the periphery requires further investigation.
引用
- Artal P, Arvaniti M, Dimou P, et al. Peripheral Vision in Patients Following Intraocular Lens Implantation: A Systematic Review and Meta-Analysis. Am J Ophthalmol. 2024. PMID: 38521156. doi:10.1016/j.ajo.2024.03.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。