文献速递眼底病与葡萄膜炎白内障与屈光手术

个性化晶状体校正改善定量眼底自发荧光分析

Personalized Lens Correction Improves Quantitative Fundus Autofluorescence Analysis.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2024-01-01

该横断面研究纳入130名参与者,其中30人在白内障术后2周接受多模态影像复查,开发并比较基于晶状体定量自发荧光(LQAF)和Scheimpflug的个体化校正公式与现行年龄公式。结果显示LQAF和年龄是最相关变量,样条模型预测误差MAE 32.2±23.4(QAF a.u.)明显低于现行年龄公式的96.1±93.5。作者认为LQAF成像对自然晶状体影响QAF的预测性最强,临床应用晶状体评分可提高QAF解读准确性,并可能使老年患者纳入未来QAF研究。

要点

  • LQAF和年龄是校正QAF最相关变量,AC-OCT和Scheimpflug被后退法剔除。
  • Scheimpflug和LQAF值升高均与QAF降低相关。
  • 样条模型MAE 32.2±23.4(QAF a.u.)明显低于现行年龄公式的96.1±93.5。

核心结论

  • LQAF成像对自然晶状体影响QAF成像的预测性最强。
  • 临床应用晶状体评分可提高QAF成像解读准确性,并可能使老年患者纳入未来QAF研究。

研究设计与样本

  • 横断面研究,纳入130名参与者,其中30人在白内障术后2周接受额外多模态影像复查。
  • 影像包括Scheimpflug原理、前节光学相干断层扫描(AC-OCT)、晶状体定量自发荧光(LQAF)和视网膜QAF成像。
  • 在30人亚组中采用最小绝对收缩和选择算子回归及后退法选择预测白内障术后QAF值的最佳晶状体评分,随后在全队列应用样条混合模型量化LQAF和Scheimpflug对QAF的影响。

主要发现

  • 年龄和LQAF测量是最相关变量,AC-OCT测量和Scheimpflug被后退法剔除。
  • Scheimpflug和LQAF值升高均与QAF降低相关。
  • 样条模型预测误差(平均绝对误差[MAE]±标准差)为32.2±23.4(QAF a.u.),明显低于现行年龄公式的MAE 96.1±93.5。
  • 样条混合模型中LQAF(P < 0.01)和Scheimpflug(P < 0.001)两个平滑项均显著。

关键数值与推荐

  • 样条模型MAE为32.2±23.4(QAF a.u.),现行年龄公式MAE为96.1±93.5。
  • 样条混合模型中LQAF平滑项P < 0.01,Scheimpflug平滑项P < 0.001。

临床怎么用

  • 作者认为,临床应用晶状体评分可提高QAF成像解读准确性,并可能使老年患者纳入未来QAF研究。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Quantitative fundus autofluorescence (QAF) currently deploys an age-based score to correct for lens opacification. However, in elderly people, lens opacification varies strongly between individuals of similar age, and innate lens autofluorescence is not included in the current correction formula. Our goal was to develop and compare an individualized formula. METHODS: One hundred thirty participants were examined cross-sectionally, and a subset of 30 participants received additional multimodal imaging 2-week post-cataract-surgery. Imaging included the Scheimpflug principle, anterior chamber optical coherence tomography (AC-OCT), lens quantitative autofluorescence (LQAF), and retinal QAF imaging. Among the subset, least absolute shrinkage and selection operator regression and backward selection was implemented to determine which lens score best predicts the QAF value after lens extraction. Subsequently, a spline mixed model was applied to the whole cohort to quantify the influence of LQAF and Scheimpflug on QAF. RESULTS: Age and LQAF measurements were found to be the most relevant variables, whereas AC-OCT measurements and Scheimpflug were eliminated by backward selection. Both an increase in Scheimpflug and LQAF values were associated with a decrease in QAF. The prediction error of the spline model (mean absolute error [MAE] ± standard deviation) of 32.2 ± 23.4 (QAF a.u.) was markedly lower compared to the current age-based formula MAE of 96.1 ± 93.5. Both smooth terms, LQAF (P < 0.01) and Scheimpflug (P < 0.001), were significant for the spline mixed model. CONCLUSIONS: LQAF imaging proved to be the most predictive for the impact of the natural lens on QAF imaging. The application of lens scores in the clinic could improve the accuracy of QAF imaging interpretation and might allow including aged patients in future QAF studies.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. von der Emde L, Rennen GC, Vaisband M, et al. Personalized Lens Correction Improves Quantitative Fundus Autofluorescence Analysis. Invest Ophthalmol Vis Sci. 2024. PMID: 38466288. doi:10.1167/iovs.65.3.13

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。