Cirrus与Spectralis光学相干断层扫描评估高透射缺陷的正面与体积比较
本研究纳入30只干性年龄相关性黄斑变性(AMD)眼,分别用Spectralis和Cirrus OCT密集扫描并重建高透射缺陷(HTD)的正面与三维图像。Cirrus正面图像定性评分高于Spectralis(P<.01),Spectralis经预处理后图像质量改善;两设备HTD二维面积及三维参数均无显著差异,提示两设备在评估AMD中HTD时可互换。
要点
- Cirrus的HTD正面图像定性评分高于Spectralis(P<.01),Spectralis经预处理重建后图像质量改善。
- 两设备HTD二维面积无差异(P=.478,ICC=0.998;Jaccard指数0.721±0.086)。
- 两设备HTD数量、体积、PALs及表面积在体积分析中均无差异(所有P≥.090)。
核心结论
- Spectralis OCT的HTD正面图像可视化可通过图像处理增强。
- 两设备三维HTD参数等效,提示在评估AMD中这些病变时可互换。
研究设计与样本
- 比较性诊断评估研究,纳入阿米什眼研究队列中30只干性AMD眼。
- 每只眼均接受Spectralis(97张B扫描/体积,共2910张B扫描)和Cirrus OCT(128张B扫描/体积,共3840张B扫描)密集黄斑体积扫描。
- 在每个B扫描上标记HTD区域,并重建为正面和三维体积图像,比较两设备间HTD体积特性。
主要发现
- Cirrus的HTD正面图像定性评分高于Spectralis(P<.01)。
- Spectralis正面图像质量在预处理和重建后改善。
- 由三维体积二维投影获得的HTD二维面积在两设备间无差异(P=.478,ICC=0.998;Jaccard指数0.721±0.086)。
- 体积分析中,两设备间HTD数量、体积、PALs和表面积均无差异(所有P≥.090)。
- 经平均脉络膜信号强度归一化的HTD信号强度在两设备间无差异(P=.861)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate and compare en face and 3-dimensional (3-D) properties of hypertransmission defects (HTDs) between different optical coherence tomography (OCT) devices using OCT volumes and reconstructed en face images. SETTINGS: Comparative diagnostic evaluation study. METHODS: Thirty eyes with dry age-related macular degeneration (AMD) that underwent dense OCT macular volume scans with both the Spectralis (97 B-scans/volume; 2910 B-scans in total) and Cirrus OCT (128 B-scans/volume; 3840 B-scans in total) from the Amish Eye Study cohort were included in this analysis. HTD regions were labeled on each B-scan and reconstructed into en face and 3-D volume images. Properties of HTD volume were compared between the 2 devices. RESULTS: The qualitative score of en face images for HTD was higher for the Cirrus compared to the Spectralis (P < .01). The quality of Spectralis en face images improved after preprocessing and reconstruction. The 2-D HTD area on en face obtained from 2-D projections of 3-D volume did not differ between devices (P = .478, ICC = 0.998; Jaccard index 0.721 ± 0.086). There was no difference in the number, volume, PALs, and surface areas of HTDs between devices in the volumetric analysis (all P ≥ .090). The signal intensity of HTD normalized by the mean choroidal signal intensity did not differ between devices (P = .861). CONCLUSIONS: The visualization of HTD on en face images from Spectralis OCT could be enhanced through image processing. The equivalence in 3-D HTD parameters between the 2 devices suggests interchangeability for assessing these lesions in AMD.