角膜生物力学特性预测异常断层角膜预后:一项前瞻性队列研究
该多中心前瞻性队列研究纳入278例患者385眼,分析稳定异常角膜断层(ACT)、亚临床圆锥角膜(SKC)、圆锥角膜及正常对照的断层与生物力学参数,提出生物力学稳定性指数(BSI)以区分稳定ACT与SKC。BSI截断值0.585时曲线下面积0.991,灵敏度93.85%、特异度97.14%;43眼首诊ACT随访1年,BSI准确度95.35%、阳性预测值100%、阴性预测值93.75%。
要点
- 稳定ACT的12/14项生物力学参数与SKC不同(P<.05),但与正常对照无差异(P>.05)。
- BSI截断值0.585区分稳定ACT与SKC的曲线下面积0.991,灵敏度93.85%、特异度97.14%。
- 43眼首诊ACT随访1年,BSI准确度95.35%、阳性预测值100%、阴性预测值93.75%。
核心结论
- 稳定异常断层角膜的生物力学特性强于亚临床圆锥角膜且接近正常角膜,可能解释其断层稳定性;BSI可能有助于预测ACT患者的疾病进展及首诊时角膜交联的可能管理。
研究设计与样本
- 多中心前瞻性队列研究,纳入278例患者385眼,包括稳定ACT 70眼、亚临床圆锥角膜65眼、圆锥角膜65眼、正常对照142眼;另设首诊ACT组43眼随访1年验证BSI。
主要发现
- 稳定ACT组断层和生物力学参数在随访期(12.73±2.57个月)保持稳定(P>.05)。
- 稳定ACT有12/14项生物力学参数与亚临床圆锥角膜不同(P<.05),但与正常对照无差异(P>.05)。
- BSI截断值0.585区分稳定ACT与亚临床圆锥角膜的曲线下面积=0.991,灵敏度93.85%,特异度97.14%。
- 43眼首诊ACT随访1年,30眼保持稳定;BSI准确度95.35%、阳性预测值100%、阴性预测值93.75%。
关键数值与推荐
- BSI截断值0.585用于区分稳定ACT与亚临床圆锥角膜,曲线下面积0.991,灵敏度93.85%,特异度97.14%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To analyze the corneal biomechanical properties in patients with abnormal corneal tomography (ACT) and predict their stability using the biomechanical stability index (BSI). DESIGN: Prospective cohort study. METHODS: Setting: Multicenter study. STUDY POPULATION: This study included 385 eyes of 278 patients with stable ACT (n = 70), subclinical keratoconus (SKC, n = 65), keratoconus (n = 65), normal controls (NL, n = 142). Forty-three eyes with first-visit ACT were included in a separate cohort (follow-up ACT group). OBSERVATION PROCEDURE: Tomographical and biomechanical parameters (Pentacam and Corvis ST) were recorded. MAIN OUTCOME MEASURES: Nonparametric tests were used for comparison. Logistic regression was employed to introduce BSI to separate stable ACT and SKC accurately. An independent dataset of 43 first-visit ACT eyes was followed up for 1 year to validate BSI's accuracy and positive and negative predictive values (PPV, NPV). RESULTS: The tomographical and biomechanical parameters in patients with Stable ACT remained stable over the follow-up period (12.73 ± 2.57 months, P > .05). Stable ACT had 12/14 biomechanical parameters different (P < .05) from SKC but not different from NL (P > .05). With a cut-off value of 0.585, BSI demonstrated the strongest ability to distinguish between stable ACT and SKC (area under the receiver operating characteristic curve = 0.991), with 93.85% sensitivity and 97.14% specificity. During the 1-year follow-up of 43 eyes (follow-up ACT group), 30 remained stable. The accuracy, PPV, and NPV of the BSI were 95.35%, 100%, and 93.75%, respectively. CONCLUSIONS: Biomechanical properties of patients with stable abnormal tomography corneas were stronger than SKC and close to normal corneas, which may explain the reason for tomographic stability. The BSI may be useful for predicting disease progression in patients with ACT and the possible management of corneal cross-linking at the first visit.
引用
- Huo Y, Chen X, Song J, et al. Corneal Biomechanical Properties to Predict Prognosis of Abnormal Tomographic Corneas: A Prospective Cohort Study. Am J Ophthalmol. 2024. PMID: 38211780. doi:10.1016/j.ajo.2024.01.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。