非洲与欧洲裔青光眼患者视网膜神经纤维层厚度测量的长期变异性
该回顾性队列研究纳入非洲裔(AD)和欧洲裔(ED)青光眼眼,分析长期视网膜神经纤维层厚度(RNFLT)变异性及相关临床因素。AD组376眼、ED组625眼的平均RNFLT变异性分别为1.62 µm和1.42 µm(p=0.002); intervening白内障摘除(CE)与更高变异性最强相关,排除干预性CE后种族差异不再显著(AD 1.40 µm vs ED 1.34 µm,p=0.280)。
要点
- AD组376眼与ED组625眼的平均RNFLT变异性分别为1.62 µm和1.42 µm(p=0.002)。
- 两族中干预性CE均与更高RNFLT变异性最强相关(β范围0.24-0.92,p<0.05)。
- 排除干预性CE后变异性降低,种族差异不再显著(AD 1.40 µm vs ED 1.34 µm,p=0.280)。
核心结论
- 长期RNFLT变异性在AD和ED眼中均显得较小,尽管识别出一些预测因素。
- 干预性CE是变异性最强预测因素,排除后种族差异不再存在。
- 研究结果提示在考虑相关因素时,RNFLT在不同种族间是可靠的。
研究设计与样本
- 回顾性队列研究,纳入来自Diagnostic Innovations in Glaucoma Study/The African Descent and Glaucoma Evaluation Study的AD和ED青光眼眼,要求≥4次访视/2年随访。
- AD组376眼(226例参与者),ED组625眼(349例参与者)。
- 计算每次检查/访视的视神经乳头RNFLT变异性,即随访期间残差的绝对误差。
- 拟合完整、基线和简约线性混合模型评估临床因素对RNFLT变异性的影响。
主要发现
- AD组平均(95%CI)RNFLT变异性为1.62(1.52,1.71)µm,ED组为1.42(1.34,1.50)µm(p=0.002)。
- AD和ED共享一些RNFLT变异性预测因素,包括眼压波动和扫描质量,但效应有所不同(p<0.05)。
- 两族中干预性CE与更高RNFLT变异性最强相关(β:0.24-0.92,p<0.05)。
- 排除干预性CE眼后,RNFLT变异性降低,种族差异不再显著(AD:1.40(1.31,1.48)µm vs ED:1.34(1.27,1.40)µm;p=0.280)。
临床怎么用
- 作者认为研究结果有助于优化结构评估策略,并提示在考虑相关因素时RNFLT在不同种族间是可靠的。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To examine long-term retinal nerve fibre layer thickness (RNFLT) variability and associated clinical factors in African (AD) and European descent (ED) individuals with glaucoma. METHODS: This retrospective cohort study included glaucoma eyes of AD and ED from Diagnostic Innovations in Glaucoma Study/The African Descent and Glaucoma Evaluation Study with ≥4 visits/2 years of follow-up. We calculated optic nerve head RNFLT variability per-examination/visit as the absolute error of its residuals across follow-up. Full, baseline and parsimonious linear-mixed models were fit to evaluate the effects of clinical factors (demographics and ocular characteristics, prior/intervening glaucoma surgeries and cataract extraction (CE), RNFLT thinning rate, scan quality, visit/testing frequency, etc) on RNFLT variability in both races. RESULTS: There were 376 and 625 eyes (226 and 349 participants) of AD and ED, and the mean (95% CI) RNFLT variability was 1.62 (1.52, 1.71) µm and 1.42 (1.34, 1.50) µm, respectively (p=0.002). AD and ED had some shared predictors of RNFLT variability, including intraocular pressure fluctuation and scan quality, although the effects varied (p<0.05). In both races, intervening CE was most strongly correlated with higher RNFLT variability (β: 0.24-0.92, p<0.05). After excluding eyes with intervening CE, RNFLT variability was reduced and the small racial difference was no longer significant (AD: 1.40 (1.31, 1.48) µm vs ED: 1.34 (1.27, 1.40) µm; p=0.280). CONCLUSIONS: Although some predictors were identified, long-term RNFLT variability appeared small for both AD and ED eyes. Moreover, the racial difference did not remain once intervening CE, the strongest predictor of variability, was eliminated. Our findings inform on strategies to optimise structural assessment and suggest that, when accounting for relevant factors, RNFLT is reliable across races.
引用
- Wu JH, Moghimi S, Walker E, et al. Long-term variability of retinal nerve fibre layer thickness measurement in patients with glaucoma of African and European descents. Br J Ophthalmol. 2024. PMID: 38164556. doi:10.1136/bjo-2023-324404