25G与27G玻璃体切除术治疗玻璃体视网膜疾病:一项大型前瞻性随机试验
该大型前瞻性随机试验将463例视网膜前膜或黄斑裂孔手术候选者随机分入27G组(227例)和25G组(236例),比较两种玻璃体切除探头的安全性和性能。结果显示两组总手术时间相似(P=0.0911),最佳矫正远视力及黄斑中心凹厚度变化在基线与1个月、3个月随访时均相似,术中及术后并发症率无显著差异;27G组无缝合玻璃体切除率为96.5%,25G组为91.1%(P=0.0170)。结论提示27G探头在手术时间和并发症方面与25G相似,同时减少玻璃体切除缝合需求。
要点
- 27G组无缝合玻璃体切除率为96.5%,25G组为91.1%(P=0.0170)。
- 两组总手术时间相似(P=0.0911)。
- 两组最佳矫正远视力、黄斑中心凹厚度变化及并发症率无显著差异。
核心结论
- 结果提示27G玻璃体切除探头在手术时间和并发症方面与25G探头相似,同时减少玻璃体切除缝合需求。
研究设计与样本
- 大型前瞻性随机研究,纳入视网膜前膜或黄斑裂孔手术候选者,随机分为27G组或25G组。
- 共纳入463例患者,27G组227例,25G组236例。
- 结局指标包括手术时间、最佳矫正远视力、眼压、黄斑中心凹厚度在基线与1个月和3个月随访间的变化,以及术中术后并发症和无缝合玻璃体切除率。
主要发现
- 两组总手术时间相似(P=0.0911)。
- 基线与1个月、3个月随访时,两组最佳矫正远视力和黄斑中心凹厚度变化相似。
- 术中及术后并发症率无显著差异。
- 无缝合玻璃体切除率27G组为96.5%,25G组为91.1%(P=0.0170)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the safety and performance clinical outcomes of the 27-gauge (G) two-dimensional cutting vitrectomy probe versus a standard 25-G probe for retinal procedures. METHODS: In this large randomized prospective study, all candidates for epiretinal membrane or macular hole surgery were randomized to the 27-G group or 25-G group. Outcome measures included surgery time, changes in best-corrected distance visual acuity, intraocular pressure, and central macular thickness between baseline and 1-month and 3-month follow-up time points. Moreover, intraoperative and postoperative complications were evaluated as well as the rate of sutureless vitrectomy. RESULTS: A total of 463 patients were included in this study, 227 patients in the 27-G group and 236 patients in the 25-G group. A similar total surgery time was found between both groups ( P = 0.0911). Similar best-corrected distance visual acuity and central macular thickness changes were observed between baseline and the 1-month and 3-month follow-up visits. No significant differences were reported in intraoperative and postoperative complications rates. The rate of sutureless vitrectomy was 96.5% for the 27-G group and 91.1% for the 25-G group ( P = 0.0170). CONCLUSION: These results suggest that 27-G vitrectomy probe is similar to 25-G probe in surgery time and complications, while decreasing the need for vitrectomy sutures.
引用
- Benzerroug M, Marchand M, Coisy S, et al. 25-GAUGE VERSUS 27-GAUGE VITRECTOMY FOR MANAGEMENT OF VITREORETINAL DISEASES: A Large Prospective Randomized Trial. Retina. 2024. PMID: 38237087. doi:10.1097/IAE.0000000000004048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。