近视性视神经病变眼的临床特征及青光眼发生相关因素
这项前瞻性观察性队列研究纳入233只无明确青光眼损害证据的近视眼,比较有无近视性视神经病变(MON)两组,并分析MON眼中发生典型青光眼损害的相关因素。结果显示,基线颞侧视网膜神经纤维层厚度较薄、筛板深度较大及视盘周围萎缩面积较大与青光眼发生显著相关。
要点
- 近视性视神经病变眼发生青光眼的风险高于无近视性视神经病变的近视眼。
- 基线颞侧RNFL较薄、筛板深度较大、视盘周围萎缩面积较大与青光眼发生相关。
- 近视导致的结构薄弱,尤其是视盘颞侧及视盘周围巩膜,可能增加近视眼发生青光眼的风险。
核心结论
- 伴有近视性视神经病变的近视眼较无近视性视神经病变的近视眼有更高的发生青光眼的风险。
- 近视所致的结构薄弱,尤其是视盘颞侧及视盘周围巩膜,可能增加伴有近视性视神经病变的近视眼发生青光眼的风险。
研究设计与样本
- 前瞻性、观察性队列研究,共纳入233只无明确青光眼损害证据的近视眼。
- 无任何视网膜神经纤维层(RNFL)或视野(VF)异常的近视眼归为无近视性视神经病变(MON)组。
- 鼻上(SN)或鼻侧RNFL变薄且颞侧或颞下(IT)区域有相应视野缺损的近视眼归为伴有MON组。
- 出现SN区域青光眼性视野(包括Bjerrum区缺损)或IT区域新发局限性RNFL缺损的近视眼定义为发生青光眼。
- 比较两组的视盘形态学特征和视神经乳头(ONH)参数。
主要发现
- 伴有MON的近视眼平均视盘周围RNFL厚度更薄(P < 0.001)、视野MD更差(P = 0.031)、IT视野缺损比例更高(P < 0.001)、扭转度更小(P = 0.047)、LCD更大(P = 0.022)。
- 伴有MON且发生青光眼的近视眼平均视盘周围RNFL厚度更薄(P = 0.009)、PPA面积更大(P = 0.049)、LCD更大(P < 0.001)、LCT更薄(P < 0.001)。
- 基线颞侧RNFL厚度较薄(HR 0.956;95% CI 0.928-0.986;P = 0.004)、基线LCD较大(HR 1.003;95% CI 1.000-1.005;P = 0.022)及PPA面积较大(HR 1.000;95% CI 1.000-1.003;P = 0.050)与青光眼发生显著相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To observe the development of glaucoma in myopic eyes with and without myopic optic neuropathy (MON) and analyze associated factors to the development of typical glaucomatous damage. DESIGN: A prospective, observational, cohort study. METHODS: A total of 233 myopic eyes with no definite evidence of glaucomatous damage were included. Myopic patients without any retinal nerve fiber layer (RNFL) or visual field (VF) abnormalities were classified as myopic eyes without MON. Myopic patients with decreased RNFL at the superonasal (SN) or nasal area, and with corresponding VF defects either in the temporal or inferotemporal (IT) region were classified as myopic eyes with MON. Myopic eyes that developed glaucoma were defined by the presence of glaucomatous VF in the SN region including defects in Bjerrum area, or a new localized RNFL defect in the IT region. Disc morphological features and optic nerve head (ONH) parameters of two groups were compared. RESULTS: Myopic eyes with MON had a thinner average peripapillary RNFL thickness (P < 0.001), worse MD of the VF (P = 0.031), a higher percentage of IT VF defects (P < 0.001), smaller torsion degree (P = 0.047), and greater LCD (P = 0.022). Myopic eyes with MON who developed glaucoma had a thinner average peripapillary RNFL thickness (P = 0.009), greater PPA area (P = 0.049), greater LCD (P < 0.001), and thinner LCT (P < 0.001). Thinner baseline temporal RNFL thickness (HR, 0.956; 95% CI, 0.928-0.986; P = 0.004), greater baseline LCD (HR, 1.003; 95% CI, 1.000-1.005; P = 0.022), and greater PPA area (HR, 1.000; 95% CI, 1.000-1.003; P = 0.050) were significantly associated factors with glaucoma development. CONCLUSIONS: Myopic eyes with MON have a greater risk to develop glaucoma compared to myopic eyes without MON. Structural weakness due to myopia, especially at the temporal side of the ONH and the peripapillary sclera, increases the risk of glaucoma in myopic eyes with MON.
引用
- Shin HJ, Park HL, Ryu HK, et al. Clinical Characteristics and Associated Factors to the Development of Glaucoma in Eyes With Myopic Optic Neuropathy. Am J Ophthalmol. 2024. PMID: 38191067. doi:10.1016/j.ajo.2024.01.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。