对比敏感度与眼病及视功能相关生活质量的关联
该横断面研究纳入1159名在密歇根州免费诊所和联邦合格健康中心接受诊疗的成人,平均年龄54.9±14.5岁,评估对比敏感度(CS)作为眼病筛查工具的价值及其与眼病和视功能问卷(VFQ)评分的关联。较好眼CS每降低0.3 log单位与青光眼、白内障、糖尿病视网膜病变(DR)和年龄相关性黄斑变性(AMD)的筛查阳性几率增加相关,较好眼CS每升高0.3 log单位与VFQ评分增加5.9分相关。作者认为单纯CS不足以识别眼病患者,但可作为全面眼科筛查的重要补充。
要点
- 较好眼CS每降低0.3 log单位与青光眼、白内障、DR和AMD筛查阳性几率增加相关。
- 较好眼CS每升高0.3 log单位与VFQ评分增加5.9分相关。
- CS预测眼病的AUC为0.53至0.73,单纯CS不足以识别眼病患者。
核心结论
- 单纯CS不足以识别眼病患者,但它是视功能的重要测量指标,可为全面眼科筛查增加价值。
研究设计与样本
- 横断面研究,纳入1159名在密歇根州免费诊所和联邦合格健康中心接受诊疗的成人。
- 参与者接受远程医疗审阅的视力检查、人口学调查和9项VFQ问卷。
- 采用逻辑回归和线性回归分析CS对眼病筛查阳性和VFQ评分的连续效应,并调整年龄和视力。
主要发现
- 纳入参与者平均年龄54.9±14.5岁,62%为女性,34%为白人,54%为黑人,10%为西班牙裔/拉丁裔,平均VFQ评分为79.7±15.3。
- CS范围为0.00至1.95 log单位(均值1.54±0.24),21%的眼有青光眼,19%有白内障,6%有DR,2%有AMD。
- AUC为0.53至0.73。
- 较好眼CS每降低0.3 log单位与青光眼(OR=1.35,CI=1.09-1.67)、白内障(OR=1.35,CI=1.05-1.72)、DR(OR=2.05,CI=1.51-2.77)和AMD(OR=2.08,CI=1.10-3.91)的筛查阳性几率增加相关。
- 较好眼CS每升高0.3 log单位与VFQ评分增加5.9分相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate contrast sensitivity (CS) as a screening tool to detect eye disease and assess its association with both eye disease and vision-related quality of life. DESIGN: Cross-sectional study. METHODS: Setting and population: Adults receiving care from a free clinic and a Federally Qualified Health Center in Michigan. MAIN OUTCOME MEASURES: Screening positive for eye disease and Visual Function Questionnaire (VFQ) score. OBSERVATION: Participants received a vision exam reviewed via telemedicine for disease, completed a demographic survey, and the 9-item VFQ. The ability of CS to predict eye disease was explored and area under the curve (AUC) is reported. Logistic and linear regression were used to investigate the continuous effect of CS on the probability of screening positive for eye disease and VFQ score, respectively, adjusting for age and visual acuity. RESULTS: 1159 included participants were, on average, 54.9 ± 14.5 years old, 62% identified as female, 34% as White, 54% as Black, 10% as Hispanic/Latino, and reported mean VFQ score of 79.7 ± 15.3. CS ranged from 0.00 to 1.95 log units (mean = 1.54 ± 0.24), 21% of eyes had glaucoma, 19% cataract, 6% DR, and 2% AMD. AUCs were 0.53 to 0.73. A 0.3 log unit decrease in better eye CS was associated with increased odds of glaucoma (odds ratio [OR] = 1.35, confidence interval [CI] = 1.09-1.67), cataract (OR = 1.35, CI = 1.05-1.72), DR (OR = 2.05, CI = 1.51-2.77), and AMD (OR = 2.08, CI = 1.10-3.91). A 0.3 log unit increase in better eye CS was associated with a 5.9 unit increase in VFQ. CONCLUSION: While CS alone is not sufficient to identify people with eye disease, it is an important measure of visual function that can add value to comprehensive eye screening.
引用
- Flaharty K, Niziol LM, Woodward MA, et al. Association of Contrast Sensitivity With Eye Disease and Vision-Related Quality of Life. Am J Ophthalmol. 2024. PMID: 38281569. doi:10.1016/j.ajo.2024.01.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。