文献速递白内障与屈光手术

闭合连续环缝线技术行Akreos人工晶状体经巩膜四点固定的长期结局

LONG-TERM OUTCOME OF TRANSSCLERAL FOUR-POINT FIXATION OF AKREOS INTRAOCULAR LENS WITH CLOSED CONTINUOUS-LOOP SUTURE.
PubMed 文献 · Retina · 2024-01-01

这项回顾性、多中心、干预性病例系列纳入两家手术医院177例患者共192眼,评估闭合连续环缝线技术行Akreos人工晶状体经巩膜四点固定的长期结局,随访至少1年。术后平均最佳矫正视力与眼压均较术前改善,角膜内皮细胞密度平均下降5.73%,未见术中并发症,结论认为该技术有效且安全。

要点

  • 192眼平均最佳矫正视力从术前0.88±0.74 logMAR提高至术后0.42±0.52 logMAR(P<0.001)。
  • 平均眼压从术前17.51±8.67 mmHg降至末次随访15.08±4.18 mmHg(P=0.001)。
  • 角膜内皮细胞密度平均下降5.73%,术后并发症以一过性眼压升高15眼(7.81%)最常见。

核心结论

  • 闭合连续环缝线技术行Akreos人工晶状体经巩膜四点固定在至少1年随访中有效且安全,视力令人满意。

研究设计与样本

  • 回顾性、多中心、干预性病例系列,来自两家手术医院共177例患者192眼,随访至少1年。

主要发现

  • 平均最佳矫正视力从术前0.88±0.74 logMAR(Snellen 20/152)提高至术后0.42±0.52 logMAR(Snellen 20/53),P<0.001。
  • 平均眼压从术前17.51±8.67 mmHg降至末次随访15.08±4.18 mmHg,P=0.001。
  • 平均角膜内皮细胞密度从2259±729 cells/mm²降至2077±659 cells/mm²,细胞丢失5.73%,P<0.001。
  • 随访期间人工晶状体固定良好,未见术中并发症。
  • 术后并发症包括一过性眼压升高15眼(7.81%)、低眼压2眼(1.04%)、视网膜脱离1眼(0.52%)和黄斑水肿1眼(0.52%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report the long-term clinical outcomes of transscleral four-point fixation of Akreos intraocular lens using a closed continuous-loop suture technique. METHODS: This was a retrospective, multicenter, interventional case series. Primary outcome measures were best-corrected visual acuity, intraocular pressure, corneal endothelial cell density, and complications with a minimum of 1-year follow-up. RESULTS: One hundred and ninety-two eyes of 177 patients from two surgical hospital sites were identified. The mean best-corrected visual acuity improved from 0.88 ± 0.74 logarithm of the minimum angle of resolution (Snellen 20/152) preoperatively to 0.42 ± 0.52 logarithm of the minimum angle of resolution (Snellen 20/53) postoperatively ( P < 0.001). The mean preoperative intraocular pressure was 17.51 ± 8.67 mmHg, and the mean postoperative intraocular pressure at final follow-up was 15.08 ± 4.18 mmHg ( P = 0.001). The mean corneal endothelial cell density significantly reduced from 2,259 ± 729 cells/mm 2 to 2077 ± 659 cells/mm 2 , representing a cell loss of 5.73% ( P < 0.001). The intraocular lens was fixed well during follow-up. There were no intraoperative complications noted. Postoperative complications included transient ocular hypertension in 15 eyes (7.81%), hypotony in two eyes (1.04%), retinal detachment in one eye (0.52%), and macular edema in one eye (0.52%). CONCLUSION: The transscleral four-point fixation Akreos intraocular lens using the closed continuous-loop suture technique was effective and safe with satisfactory visual acuity with a minimum of 1-year follow-up.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Zhu P, Yuan G, Wan L, et al. LONG-TERM OUTCOME OF TRANSSCLERAL FOUR-POINT FIXATION OF AKREOS INTRAOCULAR LENS WITH CLOSED CONTINUOUS-LOOP SUTURE. Retina. 2024. PMID: 38295391. doi:10.1097/IAE.0000000000004058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。