文献速递眼底病与葡萄膜炎

SF6与C2F6用于下方孔源性视网膜脱离修复的比较:曼彻斯特人工晶状体眼视网膜脱离研究

SF 6 COMPARED WITH C 2 F 6 FOR INFERIOR RHEGMATOGENOUS RETINAL REPAIR : The Manchester Pseudophakic Retinal Detachment Study.
PubMed 文献 · Retina · 2024-01-01

该回顾性比较研究纳入2011至2020年英国一家三级中心因下方裂孔导致的人工晶状体眼孔源性视网膜脱离并接受小切口玻璃体切除术联合SF6或C2F6填充的162只眼,总体单次手术解剖成功率为96.3%,SF6组与C2F6组分别为100.0%与94.8%(P=0.182),倾向性评分匹配后两组单次手术解剖成功率和最佳矫正视力均无显著差异。

要点

  • 总体单次手术解剖成功率为96.3%,SF6组47/47(100.0%)与C2F6组109/115(94.8%)相比P=0.182。
  • C2F6组平均裂孔数多于SF6组(4.5[2.7] vs 3.1[2.0],P=0.002),视网膜脱离范围更大(6.2[2.6] vs 5.3[2.9]个钟点,P=0.025)。
  • 倾向性评分匹配80只眼(每组40只)后,两组单次手术解剖成功率和最佳矫正视力均无显著差异。

核心结论

  • 初次玻璃体切除术联合气体填充在无并发症的人工晶状体眼下方孔源性视网膜脱离中可获得较高的单次手术解剖成功率。
  • 与SF6相比,使用长效填充剂C2F6未带来额外获益。

研究设计与样本

  • 回顾性比较研究,纳入2011至2020年英国一家三级中心因下方裂孔导致的人工晶状体眼孔源性视网膜脱离并接受小切口玻璃体切除术联合SF6或C2F6填充的162只眼。
  • 主要结局为单次手术解剖成功率,次要结局为最佳矫正视力,并使用术前所见作为协变量进行倾向性评分匹配以校正相关混杂因素。

主要发现

  • 中位(四分位距)随访82(52-182)天。
  • 总体单次手术解剖成功率为156/162(96.3%),SF6组为47/47(100.0%),C2F6组为109/115(94.8%)(P=0.182)。
  • C2F6组平均裂孔数高于SF6组(SF6:3.1[2.0],C2F6:4.5[2.7],P=0.002)。
  • C2F6组视网膜脱离范围大于SF6组(SF6:5.3[2.9]个钟点,C2F6:6.2[2.6]个钟点,P=0.025)。
  • 倾向性评分匹配后80只眼(每组40只)中,两组单次手术解剖成功率和最佳矫正视力均无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare SF 6 relative with C 2 F 6 in the anatomical and functional outcomes following pars plana vitrectomy for uncomplicated primary pseudophakic rhegmatogenous retinal detachment with inferior causative breaks. METHODS: This is a retrospective, comparative study on eyes with pseudophakic rhegmatogenous retinal detachment with inferior causative breaks that had small-gauge pars plana vitrectomy repair using SF 6 and C 2 F 6 tamponade between 2011 and 2020 at a tertiary centre in the United Kingdom. Primary outcome was single surgery anatomical success, and the secondary outcome was best-corrected visual acuity. Propensity score matching, using preoperative findings as covariates to account for relevant confounders, was performed. RESULTS: From 162 pseudophakic rhegmatogenous retinal detachment eyes with inferior causative breaks, the median (interquartile range) follow-up was 82 (52-182) days. The single surgery anatomical success was 156 (96.3%) overall: 47 of 47 (100.0%) and 109 of 115 (94.8%) in the SF 6 and C 2 F 6 groups, respectively ( P = 0.182). Relative to the SF 6 group, the C 2 F 6 group had a higher mean number of tears (SF 6 : 3.1[2.0], C 2 F 6 : 4.5[2.7], P = 0.002) and greater retinal detachment extent (SF 6 : 5.3[2.9], C 2 F 6 : 6.2[2.6] clock hours, P = 0.025). Following propensity score matching analysis, 80 eyes were matched with 40 in each group to homogenize preoperative factors. No significant difference was found in single surgery anatomical success and best-corrected visual acuity between the groups following propensity score matching. CONCLUSION: Primary pars plana vitrectomy with gas tamponade leads to a high single surgery anatomical success rate in uncomplicated pseudophakic rhegmatogenous retinal detachment with inferior causative breaks with no additional benefit associated with long-acting tamponade when comparing C 2 F 6 with SF 6 .

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Moussa G, Jalil A, Lippera M, et al. SF 6 COMPARED WITH C 2 F 6 FOR INFERIOR RHEGMATOGENOUS RETINAL REPAIR : The Manchester Pseudophakic Retinal Detachment Study. Retina. 2024. PMID: 38236936. doi:10.1097/IAE.0000000000004051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。