改良缝线技术产生临时巩膜扣带效应治疗非复杂性孔源性视网膜脱离
前瞻性纳入20例(20眼)非复杂性孔源性视网膜脱离患者,采用不可吸收缝线固定硅胶元件、可吸收缝线收紧形成巩膜嵴的改良扣带术。所有患者均实现首次视网膜复位,术后最佳矫正视力显著改善;术后1个月眼轴和柱镜度显著增加,3个月时显著回落,随访期间无明显并发症。
要点
- 改良扣带术使用5-0不可吸收缝线固定、6-0可吸收缝线收紧,所有20眼均首次复位。
- 术后1个月眼轴从24.78±2.14 mm增至25.22±2.11 mm,柱镜度从-1.99±1.03增至-2.95±1.55(均P<0.001)。
- 联合环扎组术后1个月眼轴和柱镜度变化更大(均P<0.001),随访期间无明显并发症。
核心结论
- 使用不可吸收与可吸收缝线的改良巩膜扣带术(联合或不联合环扎)为修复非复杂性孔源性视网膜脱离提供了安全有效的选择,可产生充分的临时巩膜扣带效应并引起最小的永久性屈光改变。
研究设计与样本
- 前瞻性纳入20例连续患者(20眼)非复杂性孔源性视网膜脱离,所有符合条件的受试者均行巩膜扣带术,必要时加行环扎扣带。
- 硅胶元件以5-0不可吸收缝线固定于巩膜,并以6-0可吸收缝线收紧形成嵴。
- 收集最佳矫正视力、巩膜嵴状态、眼轴、球镜度和柱镜度。
主要发现
- 所有患者均实现首次视网膜复位,术后最佳矫正视力显著改善。
- 术后1个月巩膜嵴明显且在位,术后3个月减弱。
- 术后1个月眼轴从术前24.78 mm±2.14 mm增至25.22 mm±2.11 mm,柱镜度从-1.99±1.03增至-2.95±1.55(均P<0.001)。
- 术后3个月眼轴、球镜度和柱镜度较术后1个月显著下降(均P<0.05)。
- 整个随访期间未观察到明显并发症;加行环扎扣带者在术后1个月眼轴和柱镜度变化更大(均P<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To introduce a surgical technique for temporary scleral buckling of noncomplex rhegmatogenous retinal detachment using a combination of nonabsorbable and absorbable sutures that would induce minimal permanent refractive changes. METHODS: Twenty consecutive patients (20 eyes) with noncomplex rhegmatogenous retinal detachment were prospectively included. Scleral buckling was performed in all eligible subjects, and encircling buckling was added when necessary. The silicone elements were fixed on the sclera with 5-0 nonabsorbable sutures and tightened to form a ridge with 6-0 absorbable sutures. Best-corrected visual acuity, scleral ridge status, axial length, spherical diopter, and cylinder diopter were collected. RESULTS: All patients achieved primary retinal reattachment with significant improvement of best-corrected visual acuity after surgery. Scleral ridge was obvious and in situ at the 1-month follow-up but diminished at the 3-month follow-up. At the 1-month follow-up, axial length increased from 24.78 mm ± 2.14 mm preoperatively to 25.22 mm ± 2.11 mm, and cylinder diopter increased from -1.99 ± 1.03 to -2.95 ± 1.55 (both P < 0.001). At the 3-month follow-up, axial length, spherical diopter, and cylinder diopter decreased significantly compared with the values at the 1-month follow-up (all P < 0.05). No obvious complications were observed during the whole follow-up. Patients who underwent additional encircling buckling exhibited greater changes in axial length and cylinder diopter at the 1-month follow-up (both P < 0.001). CONCLUSION: The modified technique of scleral buckling with/without encircling buckling using both nonabsorbable and absorbable sutures offers a safe and effective option to repair noncomplex rhegmatogenous retinal detachment, which would offer an adequate temporary scleral buckling effect and induce minimal permanent refractive changes.
引用
- Zhang Z. A Modified Suturing Technique to Produce Temporary Scleral Buckling Effect for Noncomplex Rhegmatogenous Retinal Detachment. Retina. 2024. PMID: 38285651. doi:10.1097/IAE.0000000000004031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。