文献速递小儿眼科与斜弱视神经眼科

眼动追踪与Teller视标卡评估儿童皮层性/大脑性视觉障碍视力的比较

Comparison of Eye Tracking and Teller Acuity Cards for Visual Acuity Assessment in Pediatric Cortical/Cerebral Visual Impairment.
PubMed 文献 · Am J Ophthalmol · 2023-12-07

该可靠性与有效性研究纳入41例皮层性/大脑性视觉障碍(CVI)儿童,比较眼动追踪与Teller视标卡(TAC)测量视力的表现。眼动追踪测得的视力重测信度优秀(ICC=0.81,P<.0001),TAC重测信度一般(ICC=0.42,P=.04);眼动追踪光栅视力与视觉行为量表(VBS)评分强相关(r=0.72,P<.0001),TAC与VBS中度相关(r=0.50,P=.009)。作者认为在该队列中眼动追踪可能比人工评估更准确,尚需未来研究确定CVI儿童视功能纵向评估的最佳方法。

要点

  • 眼动追踪视力重测信度优秀(ICC=0.81,P<.0001),TAC重测信度一般(ICC=0.42,P=.04)。
  • 眼动追踪与TAC中度相关(r=0.43,P=.03),眼动追踪光栅视力与VBS强相关(r=0.72,P<.0001)。
  • 作者认为眼动追踪相机客观确定注视方向在该人群中可能比人工评估更准确。

核心结论

  • 在该CVI儿童队列中,眼动追踪测得的光栅视力重测信度更高,且与小儿神经眼科视觉行为评估的相关性强于Teller视力。
  • 由眼动追踪相机客观确定注视方向在该人群中可能比人工评估更准确。
  • 未来研究需要确定CVI儿童视功能与功能性视觉纵向评估的最佳方法。

研究设计与样本

  • 可靠性与有效性研究,从单一学术性小儿神经眼科门诊招募41例CVI儿童。
  • 所有儿童完成眼动追踪视力测量,其中26例由设盲检查者完成TAC评估。
  • 另有2名小儿神经眼科医师采用6级视觉行为量表(VBS)评估视觉行为。
  • 眼动追踪与TAC在基线和1个月时各进行一次,采用组内相关系数(ICC)评估重测信度。
  • 眼动追踪与TAC视力之间及与VBS评分之间采用Spearman相关系数分析。

主要发现

  • 眼动追踪视力重测信度优秀(ICC=0.81,P<.0001)。
  • 儿童CVI中TAC重测信度一般(ICC=0.42,P=.04)。
  • 眼动追踪与TAC中度相关(r=0.43,P=.03)。
  • TAC与VBS评分中度相关(r=0.50,P=.009)。
  • 眼动追踪光栅视力与VBS评分强相关(r=0.72,P<.0001)。

临床怎么用

  • 作者认为,由眼动追踪相机客观确定注视方向在该CVI人群中可能比人工评估更准确。
  • 作者指出,未来研究需要确定CVI儿童视功能与功能性视觉纵向评估的最佳方法。

局限性

  • 未来研究需要确定CVI儿童视功能与功能性视觉纵向评估的最佳方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare eye tracking and Teller acuity cards (TAC) for assessment of visual acuity in children with cortical, or cerebral, visual impairment (CVI). DESIGN: Reliability and validity study. METHODS: We recruited 41 children with CVI from a single academic pediatric neuro-ophthalmology clinic. All children performed eye tracking to measure visual acuity, and 26 children completed TAC assessment by a masked examiner. Additionally, 2 pediatric neuro-ophthalmologists graded visual behavior using the 6-level Visual Behavior Scale (VBS). Eye tracking and TAC were performed at baseline and at 1 month. Test-retest reliability of eye tracking and TAC were assessed using the intraclass correlation coefficient (ICC). Eye tracking and TAC visual acuities were correlated with one another and VBS scores using the Spearman correlation coefficient. RESULTS: Test-retest reliability was excellent for eye tracking measurement of visual acuity (ICC = 0.81, P < .0001). For pediatric CVI, TAC test-retest reliability was fair (ICC = 0.42, P = .04). There was a moderate correlation between eye tracking and TAC (r = 0.43, P = .03) and between TAC and VBS score (r = 0.50, P = .009), and a strong correlation between eye tracking grating acuity and VBS score (r = 0.72, P < .0001). CONCLUSIONS: In our cohort of children with CVI, grating acuity measured by eye tracking demonstrated higher test-retest reliability and stronger correlation with pediatric neuro-ophthalmologic assessment of visual behavior than Teller acuity. Objective determination of gaze direction by an eye tracking camera may be more accurate than human assessment in this population. Future research is needed to determine the optimal methods of longitudinal assessment of visual function and functional vision in children with CVI.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Chang MY, Borchert MS. Comparison of Eye Tracking and Teller Acuity Cards for Visual Acuity Assessment in Pediatric Cortical/Cerebral Visual Impairment. Am J Ophthalmol. 2023. PMID: 38065248. doi:10.1016/j.ajo.2023.11.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。