人角膜与结膜上皮对初次软性接触镜佩戴的上皮免疫细胞反应
研究纳入54名从未佩戴接触镜者,用活体共聚焦显微镜评估佩戴软性接触镜2小时前后中央、周边、角膜缘角膜及球结膜的上皮免疫细胞密度与形态。结果显示除中央角膜外各区域上皮免疫细胞密度显著增加,中央与周边角膜细胞体增大且长树突比例升高,周边与角膜缘厚树突者增多。
要点
- 佩戴软性接触镜2小时后,除中央角膜外各区域上皮免疫细胞密度均显著增加(均P < 0.001)。
- 中央与周边角膜上皮免疫细胞体显著增大、长树突比例升高(均P < 0.001)。
- 周边(P = 0.04)与角膜缘(P < 0.001)角膜厚树突上皮免疫细胞者增多。
核心结论
- 短时间佩戴软性接触镜后上皮免疫细胞主要被募集至周边区域,中央角膜未见显著募集。
- 中央与周边角膜均表现出增强的抗原捕获能力,周边角膜区域迁移能力增加,提示短时间佩戴接触镜后上皮免疫细胞活化。
研究设计与样本
- 研究为对54名从未佩戴接触镜者(平均年龄24.8 ± 9.8岁,44%为女性)在基线与佩戴1-Day ACUVUE MOIST软性接触镜2小时后进行活体共聚焦显微镜检查。
- 采集中央、颞侧远周边与角膜缘角膜及球结膜图像,手动计数上皮免疫细胞密度并对形态进行分级。
- 采用广义估计方程模型及适当事后分析比较佩戴前后上皮免疫细胞参数差异。
主要发现
- 佩戴软性接触镜2小时后,除中央角膜外所有区域上皮免疫细胞密度显著增加(均P < 0.001)。
- 佩戴后中央与周边角膜上皮免疫细胞体尺寸显著增大,且更高比例参与者出现长树突上皮免疫细胞(均P < 0.001)。
- 佩戴后周边角膜(P = 0.04)与角膜缘角膜(P < 0.001)出现厚树突上皮免疫细胞的参与者数量显著增加。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study was to assess the immediate ocular immune response to soft contact lens (CL) wear by examining presumed epithelial immune cell (EIC) density and morphology at the central, peripheral, limbal cornea, and conjunctiva. METHODS: Fifty-four participants naïve to CL wear (mean age = 24.8 ± 9.8 years, 44% female participants), were examined using in vivo confocal microscopy at baseline and after 2 hours of CL wear (1-Day ACUVUE MOIST). Images were captured at the central, temporal far peripheral and limbal cornea, and bulbar conjunctiva. EIC density was counted manually and morphology was graded. Differences in EIC parameters pre- and post-CL wear were examined using a generalized estimating equation model with appropriate post hoc analyses. RESULTS: After 2 hours of soft CL wear, there was a significant increase in EIC density in all regions other than the central cornea (all P < 0.001). Cell body size was significantly larger, and a higher proportion of participants exhibited EIC with long dendrites after lens wear at the central and peripheral cornea (both P < 0.001). There was a significant increase in the number of participants displaying EIC with thick dendrites at the peripheral (P = 0.04) and limbal cornea (P < 0.001) after lens wear. CONCLUSIONS: EICs were primarily recruited to the peripheral regions, whereas the central cornea shows no significant recruitment after short-term CL wear. Both central and peripheral corneas exhibited an enhanced antigen capture capacity, whereas migratory capacity was increased in the peripheral corneal regions suggesting EIC activation following a short period of CL wear.
引用
- Mobeen R, Stapleton F, Chao C, et al. Epithelial Immune Cell Response to Initial Soft Contact Lens Wear in the Human Corneal and Conjunctival Epithelium. Invest Ophthalmol Vis Sci. 2023. PMID: 38099736. doi:10.1167/iovs.64.15.18
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。