文献速递青光眼

带眼外储液器的房水引流装置用于成人开角型青光眼:美国眼科学会报告

Aqueous Shunts with Extraocular Reservoir for Open-Angle Adult Glaucoma: A Report by the American Academy of Ophthalmology.
PubMed 文献 · Ophthalmology · 2023-12-08

美国眼科学会系统评估了带眼外储液器的房水引流装置治疗成人开角型青光眼的疗效与安全性,检索截至2023年4月,最终纳入28篇文献(25篇Ⅰ级、3篇Ⅱ级)。结果显示该装置可降低眼压,在有既往切口手术眼成功率优于小梁切除术,无既往手术眼作为初次手术成功率低于小梁切除术。

要点

  • 带眼外储液器的房水引流装置可使眼压较基线降低三分之一至二分之一,降幅取决于作为初次还是再次青光眼手术。
  • 有既往切口手术眼,房水引流装置成功率优于小梁切除术;无既往切口手术眼作为初次手术,成功率低于小梁切除术。
  • 非阀门装置较阀门装置长期眼压略低、抗青光眼药物使用更少、需额外青光眼手术更少,两者均延缓视野进展且疗效与小梁切除术相当。

核心结论

  • 带眼外储液器的房水引流装置(包括阀门和非阀门装置)是降低眼压的有效策略,强烈Ⅰ级证据支持临床医生用于成人开角型青光眼管理。

研究设计与样本

  • 美国眼科学会眼科技能评估报告,检索PubMed数据库截至2023年4月,仅纳入2008年上次评估后发表的文献。
  • 初筛419篇摘要,58篇全文分析,最终纳入28篇,由方法学家按证据等级评定:25篇Ⅰ级、3篇Ⅱ级,无Ⅲ级。

主要发现

  • 植入带眼外储液器的房水引流装置可使眼压较基线降低三分之一至二分之一,取决于作为初次还是再次青光眼手术。
  • 有既往切口手术眼,房水引流装置成功率优于小梁切除术;无既往切口手术眼作为初次手术,成功率低于小梁切除术。
  • 阀门和非阀门装置均有效,非阀门装置长期眼压略低、抗青光眼药物使用更少、需额外青光眼手术更少。
  • 两种装置均延缓视野进展,疗效与小梁切除术相当。
  • 推荐房水引流装置植入术后早期抑制房水生成以管理术后高压期和长期眼压控制;无强证据支持开角型青光眼常规使用丝裂霉素C。

关键数值与推荐

  • 带眼外储液器的房水引流装置可使眼压较基线降低三分之一至二分之一。
  • 有既往切口手术眼,房水引流装置成功率优于小梁切除术;无既往切口手术眼作为初次手术,成功率低于小梁切除术。
  • 非阀门装置较阀门装置长期眼压略低、抗青光眼药物使用更少、需额外青光眼手术更少。
  • 推荐房水引流装置植入术后早期抑制房水生成以管理术后高压期和长期眼压控制。
  • 无强证据支持开角型青光眼房水引流装置植入常规使用丝裂霉素C。

临床怎么用

  • 强烈Ⅰ级证据支持临床医生使用带眼外储液器的房水引流装置(包括阀门或非阀门装置)管理成人开角型青光眼。
  • 推荐房水引流装置植入术后早期抑制房水生成以管理术后高压期和长期眼压控制。
  • 无强证据支持开角型青光眼房水引流装置植入常规使用丝裂霉素C。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the recently published literature on the efficacy and safety of the use of aqueous shunts with extraocular reservoir for the management of adult open-angle glaucomas (OAGs). METHODS: A search of peer-reviewed literature was last conducted in April 2023 of the PubMed database and included only articles published since the last aqueous shunt Ophthalmic Technology Assessment, which assessed articles published before 2008. The abstracts of these 419 articles were examined, and 58 studies were selected for full-text analysis. After inclusion and exclusion criteria were applied, 28 articles were selected and assigned ratings by the panel methodologist according to the level of evidence. Twenty-five articles were rated level I and 3 articles were rated level II. There were no level III articles. RESULTS: Implantation of aqueous shunts with extraocular reservoir can lower intraocular pressure (IOP) by between one-third and one-half of baseline IOP, depending on whether it is undertaken as the primary or secondary glaucoma surgery. Success rates for aqueous shunts were found to be better than for trabeculectomies in eyes with prior incisional surgery. Conversely, in eyes without prior incisional surgery, implantation of aqueous shunts was found to have an overall lower success rate as the primary glaucoma procedure compared with trabeculectomy. Although both valved and nonvalved aqueous shunts with extraocular reservoir were effective, the nonvalved device generally achieved slightly lower long-term IOPs with fewer glaucoma medications and less need for additional glaucoma surgery. Both devices slow the rates of visual field progression with efficacy comparable with that of trabeculectomy. Early aqueous humor suppression after aqueous shunt implantation is recommended for the management of the postoperative hypertensive phase and long-term IOP control. No strong evidence supports the routine use of mitomycin C with aqueous shunt implantation for OAG. CONCLUSIONS: Implantation of aqueous shunts with extraocular reservoir, including valved or nonvalved devices, has been shown to be an effective strategy to lower IOP. Strong level I evidence supports the use of aqueous shunts with extraocular reservoir by clinicians for the management of adult OAG. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Chopra V, Takusagawa HL, Rosdahl JA, et al. Aqueous Shunts with Extraocular Reservoir for Open-Angle Adult Glaucoma: A Report by the American Academy of Ophthalmology. Ophthalmology. 2023. PMID: 38069945. doi:10.1016/j.ophtha.2023.10.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。