文献速递神经眼科

深度学习系统在急诊科非散瞳眼底照片中检测视乳头水肿的应用

Application of a Deep Learning System to Detect Papilledema on Nonmydriatic Ocular Fundus Photographs in an Emergency Department.
PubMed 文献 · Am J Ophthalmol · 2023-11-04

本研究对FOTO-ED研究中828例患者的1608张非散瞳眼底照片进行回顾性二次分析,测试改良版BONSAI深度学习系统检测视乳头水肿的性能。系统区分正常与异常视盘AUC 0.92,区分视乳头水肿与正常及其他异常AUC 0.97。结论认为该系统能可靠识别视乳头水肿和正常视盘,在配备非散瞳眼底相机的急诊科和非眼科诊所有作为诊断辅助工具的巨大潜力。

要点

  • BONSAI系统区分正常与异常视盘:AUC 0.92,敏感度75.6%,特异度89.6%。
  • BONSAI系统区分视乳头水肿与正常及其他异常:AUC 0.97,敏感度84.0%,特异度98.9%。
  • 6例单眼视乳头水肿漏诊患者被系统正确识别为另一眼存在视乳头水肿。

核心结论

  • BONSAI深度学习系统能够可靠识别FOTO-ED研究中获得的非散瞳照片上的视乳头水肿和正常视盘。
  • 该系统在配备非散瞳眼底相机的急诊科和非眼科诊所有作为诊断辅助工具的巨大潜力。

研究设计与样本

  • 回顾性二次分析,数据来自FOTO-ED研究队列。
  • 测试数据集包括828例患者的1608张照片。
  • 照片按深度学习系统使用的视盘分类系统重新分类为正常视盘、视乳头水肿和其他视盘异常。
  • 以专家神经眼科医师为参考,采用一对多策略计算AUC、敏感度和特异度。

主要发现

  • 区分正常与异常视盘:AUC 0.92(95%CI 0.90-0.93),敏感度75.6%(73.7%-77.5%),特异度89.6%(86.3%-92.8%)。
  • 区分视乳头水肿与正常及其他异常:AUC 0.97(95%CI 0.95-0.99),敏感度84.0%(75.0%-92.6%),特异度98.9%(98.5%-99.4%)。
  • 6例单眼视乳头水肿漏诊患者被深度学习系统正确识别为另一眼存在视乳头水肿。

临床怎么用

  • 原文结论认为该系统在配备非散瞳眼底相机的急诊科和非眼科诊所有作为诊断辅助工具的巨大潜力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The Fundus photography vs Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) studies showed that ED providers poorly recognized funduscopic findings in patients in the ED. We tested a modified version of the Brain and Optic Nerve Study Artificial Intelligence (BONSAI) deep learning system on nonmydriatic fundus photographs from the FOTO-ED studies to determine if the deep learning system could have improved the detection of papilledema had it been available to ED providers as a real-time diagnostic aid. DESIGN: Retrospective secondary analysis of a cohort of patients included in the FOTO-ED studies. METHODS: The testing data set included 1608 photographs obtained from 828 patients in the FOTO-ED studies. Photographs were reclassified according to the optic disc classification system used by the deep learning system ("normal optic discs," "papilledema," and "other optic disc abnormalities"). The system's performance was evaluated by calculating the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 1-vs-rest strategy, with reference to expert neuro-ophthalmologists. RESULTS: The BONSAI deep learning system successfully distinguished normal from abnormal optic discs (AUC 0.92 [95% confidence interval {CI} 0.90-0.93]; sensitivity 75.6% [73.7%-77.5%] and specificity 89.6% [86.3%-92.8%]), and papilledema from normal and others (AUC 0.97 [0.95-0.99]; sensitivity 84.0% [75.0%-92.6%] and specificity 98.9% [98.5%-99.4%]). Six patients with missed papilledema in 1 eye were correctly identified by the deep learning system as having papilledema in the other eye. CONCLUSIONS: The BONSAI deep learning system was able to reliably identify papilledema and normal optic discs on nonmydriatic photographs obtained in the FOTO-ED studies. Our deep learning system has excellent potential as a diagnostic aid in EDs and non-ophthalmology clinics equipped with nonmydriatic fundus cameras. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Biousse V, Najjar RP, Tang Z, et al. Application of a Deep Learning System to Detect Papilledema on Nonmydriatic Ocular Fundus Photographs in an Emergency Department. Am J Ophthalmol. 2023. PMID: 37926337. doi:10.1016/j.ajo.2023.10.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。