文献速递角膜与眼表疾病

鲍曼层覆盖移植作为圆锥角膜最具挑战性病例的微创治疗

Bowman Layer Onlay Grafting as a Minimally Invasive Treatment for the Most Challenging Cases in Keratoconus.
PubMed 文献 · Am J Ophthalmol · 2023-11-05

前瞻性介入病例系列纳入21眼进展期晚期圆锥角膜,行鲍曼层覆盖移植,随访6至36个月(平均21±11个月)。总体最大角膜曲率从术前76±12D降至术后72±9D(P=.015),组2(术前Kmax≥69D,n=14)下降6D(P=.002),组1(术前Kmax<69D,n=7)无变化;组2最佳眼镜矫正视力从术前0.8±0.4改善至术后0.4±0.2 logMAR(P=.032),最佳接触镜矫正视力保持稳定(P>.05)。

要点

  • 鲍曼层覆盖移植为完全眼外微创技术,晚期进展性圆锥角膜可获得最多-6D的角膜变平。
  • 术前Kmax≥69D组最大角膜曲率下降6D(P=.002),术前Kmax<69D组无变化。
  • 术前Kmax≥69D组最佳眼镜矫正视力从0.8±0.4改善至0.4±0.2 logMAR(P=.032),最佳接触镜矫正视力保持稳定。

核心结论

  • 鲍曼层覆盖移植是一种完全眼外的微创手术技术,在晚期进展性圆锥角膜眼中提供最多-6D的角膜变平,允许继续(巩膜)接触镜配戴,从而保留最佳接触镜矫正视力。

研究设计与样本

  • 前瞻性介入病例系列,共21眼接受鲍曼层覆盖移植,随访6至36个月(平均21±11个月)。
  • 按术前最大角膜曲率分为两组:组1术前Kmax<69D(n=7),组2术前Kmax≥69D(n=14)。

主要发现

  • 全部21例手术均无术中并发症。
  • 总体最大角膜曲率从术前76±12D降至术后6至36个月72±9D(P=.015)。
  • 组2最大角膜曲率下降6D(P=.002),组1最大角膜曲率无变化。
  • 组1平均最佳眼镜矫正视力保持稳定;组2最佳眼镜矫正视力从术前0.8±0.4改善至术后0.4±0.2 logMAR(P=.032)。
  • 最佳接触镜矫正视力保持稳定(P>.05);术后最初数周内2眼因意外移除绷带镜需鲍曼层移植物复位,4眼因再上皮化不完全行鲍曼层再移植,1眼术后12个月因外伤性角膜糜烂行鲍曼层再移植;末次随访时所有眼移植物完全再上皮化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To analyze the clinical outcomes after Bowman layer (BL) onlay grafting for the treatment of progressive, advanced keratoconus. DESIGN: Prospective, interventional case series. METHODS: Twenty-one eyes underwent BL onlay grafting. After removing the epithelium, a single or double BL graft was "stretched" onto the corneal surface, allowed to dry-in, and a soft bandage lens was placed until the graft was re-epithelialized. Best spectacle- and/or best contact lens-corrected visual acuity (BSCVA/BCLVA), corneal tomography, and postoperative complication rates were analyzed for the total group and 2 subgroups (group 1: preoperative maximum keratometry [Kmax] <69 diopters [D; n = 7); group 2: preoperative Kmax ≥69 D [n = 14]). Follow-up ranged from 6 to 36 months (mean 21 ± 11 months). RESULTS: All 21 surgeries were uneventful. Overall, Kmax changed from 76 ± 12 D preoperatively to 72 ± 9 D at 6 to 36 months postoperatively (P = .015). Kmax decreased by 6 D in group 2 (P = .002) but did not change in group 1. Average BSCVA remained stable for group 1 and improved from preoperatively 0.8 ± 0.4 to 0.4 ± 0.2 logarithm of the minimum angle of resolution postoperatively in group 2 (P = .032); BCLVA remained stable (P > .05). Within the first postoperative weeks, 2 eyes required BL graft repositioning after inadvertent bandage lens removal and 4 eyes underwent BL retransplantation for incomplete re-epithelialization. One eye underwent BL regrafting 12 months postoperatively after traumatic corneal erosion. All eyes showed a completely re-epithelialized graft at the last available follow-up. CONCLUSIONS: BL onlay grafting is a completely extraocular, minimally invasive surgical technique, providing up to -6 D of corneal flattening in eyes with advanced progressive keratoconus, allowing for continued (scleral) contact lens wear and therefore preserving the BCLVA.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. van der Star L, Vasiliauskaitė I, Oellerich S, et al. Bowman Layer Onlay Grafting as a Minimally Invasive Treatment for the Most Challenging Cases in Keratoconus. Am J Ophthalmol. 2023. PMID: 37935272. doi:10.1016/j.ajo.2023.10.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。