文献速递角膜与眼表疾病

配戴接触镜对年轻有症状与无症状使用者眼表感觉神经功能的影响

Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2023-01-01

研究比较年轻无症状(CL-A)与有症状(CL-S)接触镜配戴者及框架眼镜(EG)使用者的角膜感觉神经功能。CL-A与EG对机械和化学刺激评分相似,但CL-A刺激感更强;CL-S冷觉检测显著更差;CL-A眨眼频率更高、泪膜破裂时间更短、眼表温度更低。结论认为配戴接触镜改变角膜敏感性、眨眼和泪液,无症状者已出现与伤害感受器敏化和冷温度感受器抑制一致的改变。

要点

  • CL-A对机械和化学刺激的评分与EG相似,但CL-A报告的刺激感更强(p<0.05)。
  • CL-S对冷刺激的检测能力显著差于CL-A和EG(p<0.05)。
  • CL-A眨眼频率高于EG(p<0.01)、泪膜破裂时间短于EG(p<0.001),眼表温度低于EG(p<0.05)。

核心结论

  • 配戴接触镜会改变年轻志愿者的角膜敏感性、眨眼和泪液。
  • 即使尚未出现临床炎症体征,也表现出与角膜伤害感受器敏化和冷温度感受器抑制一致的角膜敏感性改变,这些现象在炎症条件下出现。
  • CL-A与CL-S之间角膜敏感性和眼表温度的差异可能反映眼表神经损伤和炎症的程度。

研究设计与样本

  • 研究纳入接触镜配戴者(23.8±1.0岁,n=31),按OSDI≥13分为有症状组CL-S(n=14)和无症状组CL-A。
  • 对照组为框架眼镜使用者(EG;24.5±0.8岁,n=29),OSDI<13。
  • 测量机械、化学(气体感觉计)和冷(4°C盐水滴)刺激引起的感觉(视觉模拟量表VAS),并测量泪液量、泪膜破裂时间(TBUT)、眨眼频率(BF)和眼表温度(OST;红外热成像)。

主要发现

  • CL-A与EG对机械和化学刺激的评分相似,但CL-A报告的刺激感更强(p<0.05)。
  • CL-A与EG对冷刺激的VAS强度无差异,而CL-S对冷刺激的检测能力显著更差(p<0.05)。
  • CL-A泪液量与EG相似,眨眼频率高于EG(p<0.01),TBUT短于EG(p<0.001);CL-S的眨眼和TBUT也显著改变(p<0.01)。
  • CL-A的眼表温度显著低于EG(p<0.05),而CL-S无此差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. METHODS: CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. RESULTS: Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. CONCLUSIONS: Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Pastor-Zaplana JÁ, Gallar J, Acosta MC, et al. Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users. Invest Ophthalmol Vis Sci. 2023. PMID: 37938935. doi:10.1167/iovs.64.14.12

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。